• Keine Ergebnisse gefunden

Comparison of metabolite levels in serum and tears: implications for the dilution of autologous-serum eyedrops

N/A
N/A
Protected

Academic year: 2022

Aktie "Comparison of metabolite levels in serum and tears: implications for the dilution of autologous-serum eyedrops"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

COMPARISON OF METABOLITE LEVELS IN

SERUM AND TEARS: IMPLICATIONS FOR THE DILUTION OF AUTOLOGOUS-SERUM-EYE-

DROPS

D. Wandel 1, C. Steuer 2, J.-P. Sigle 3, L. Bernasconi 2, R. Egger1

1 Kantonsspital Aarau, Pharmacy, Aarau, Switzerland

2 Kantonsspital Aarau, Clinical Chemistry and Clinical Immunology, Aarau, Switzerland

3 Stiftung Blutspende SRK Aargau-Solothurn, Switzerland

Background No general standards exist for the optimal dilution factor of autologous serum eye drops (ASED) to treat dry eye syndrome (DES) [1, 2]. While dilution reduces patient burden, simplifies logistics and potentially decreases anti-proliferative effects from TGF-β, better epithelial healing with non-diluted ASED in Sjögren-Syndrome, but not in non-Sjögren DES has been reported [2].

Objectives The ratio of serum to tear concentration for a range of metabolites in ASED after prolonged storage time was determined to define dilution that maintains metabolite concentration equal or above those in tears.

Methods After autologous whole blood donation, unit dose ASED were prepared and stored at -20°C for 9 months. Concentration changes of 14 sphingomyelines (SM), 14 lysophosphatidylcholines (LPC) and 76 phosphatidylcholines (PC) were determined in ASED on days (d) 0 and 273 by LC-MS/MS using the Absolute/DQ®-p180-Kit (Biocrates Life Sciences) and compared to those in tears of the same person.

Results The concentrations of all SM in ASED increased by 30% to 80% within 9 months. Compared to tears, the concentrations were 10-fold (d0) to 14-fold (d273) higher. The concentrations of all LPC decreased by 50%-75%, with 20- and 5- times higher levels on d0 and d273 in ASED compared to tears. Most PC showed a less than 2-fold increase while PC ae C30:1/C38:1/C38:2 increased by 5-6- fold. “ae” denotes that one of the moieties is a fatty alcohol and bound via an ether bond. In the sum, all PC-concentrations were about 16-19- fold higher in ASED (d0-d273) than in tears.

Acknowledgements

Ines Maria Hartmann1, Jasmin Leweke2

24th EAHP Congress, Barcelona, Spain, March 2019

Conclusions We observed an increase in SM probably through the release of sphingosine-1- phosphate from platelets during blood clotting. The decrease in LPC may be linked to a shift from LPC to PC through the presence of LPC- acyltransferases. After 9 months at -20°C, the LPC levels still exceeded those in tears by 5-fold. These data support a dilution up to 5-fold as suggested by others [reviewed in 2].

1. Drew VJ et al. Front Med (Lausanne).

(2018) 5:33.

2. The Royal College of Ophthalmologists guidelines on serum eye drops for the treatment of severe ocular surface desease. (2017).

Concentrations of SM in serum at d0, d273 and in tears

Concentrations of LPC in serum at d0, d273 and in tears

Concentrations of PC ae in serum at d0, d273 and in tears

3PC-036; ATC: S01 - Ophthalmologicals

Because certain patient populations may benefit from less diluted ASED, an individual approach seems indicated until more clinical information stratified by cause and severity of DES is available.

Referenzen

ÄHNLICHE DOKUMENTE

Summary: A new commercially available Chemiluminescence immunoassay for the quantitative measurement of human chorionic gonadotropin and its -subunit in serum was compared with

A preliminary reference ränge of human serum samples was established ranging up to 1.0 U/l. In sera of patients with acute pancreatitis we found activities up to 20 U/l. The

Mean plasma deoxy- corticosterone concentrations in normal subjects repor- ted hitherto in the literature exhibit a considerable variability (range: 50-260 ng/1) which is obviously

The saliva/serum concentration ratio of digoxin (CSSA/CS) was 0.69 after a single dose. This value was close to the one reported by Mahmod et al. The digoxin concentration in

Comparison of the creatinine concentration in 123 pa- tient sera determined with the fading fraction method (No. 5) and the Fuller's earth procedure with deprotein- ization as

Using a widely available analyser (Hitachi 737/Boehringer), we therefore determined the effects of storage time and temperature on the measured concentrations of the following

The use of the mixed anhydride method for coupling cortisol-3-(0-carboxymethyl) oxime to bovine thyro- globulin is, because of the alkaline conditions, to be prefered for

Two-hundred μΐ of DAKO anti Lp(a) antibody which had been labelled with biotin as described previously (26) and diluted in assay buffer to a final concentration of 1 mg/1 were