YIN , Regulation in the Rack Nr. WSLA 16.0.2
Place: Booster (ABOMA-YIN)
Supply: 350V/100mA (two units) fug MCN 35-350 Current: nominal 1070A max. 1800A
Current transformer 1 : Pearson model 110, number 94'624 1000A 100V (1M Ohm) 50V (50 Ohm) ,near the magnet.
Cable from current transformer1 to regulation nr: 30'000-102085 Current transformer 2 : Pearson model 110, number 94'625 1000A 100V (1M Ohm) 50V (50 Ohm)
Cable from current transformer2 to regulation nr: 30'000-102086
Attenuator : 20dB 30Watt RADIALL R41720139 and 50 Ohm Attenuator 1000A 1000/(10*2*10) = 5Volt
Factors
Current measurementfactor CPD: 1000A 5Volt.
Voltage supply measurement : 350V 8Volt Vset : 10V 350Volt
Bsp. Vset(supply)=6.8Volt 238Volt 1658A pos. 1417A neg.
Fail level
Limite for current 1829A (9.13Volt) Limite for voltage supply 350V (9.8Volt)
LabViev factors Supply Faktor 43.98 I read Faktor 200 I set Faktor 238
Thyristor : Westcode 0405 CH04 FH0 001S (400Volt)
Measurement : 1500,4Apos. 1277,5Aneg. Supply 215,82Volt