• Keine Ergebnisse gefunden

Correction to: Integrated device for colorimetric detection of arsenite using polyethylene glycol capped gold nanoparticles—Lab‑on‑chip

N/A
N/A
Protected

Academic year: 2022

Aktie "Correction to: Integrated device for colorimetric detection of arsenite using polyethylene glycol capped gold nanoparticles—Lab‑on‑chip"

Copied!
3
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Vol.:(0123456789)

1 3

Toxicology and Environmental Health Sciences (2021) 13:425–427 https://doi.org/10.1007/s13530-021-00108-3

PUBLISHER CORRECTION

Correction to: Integrated device for colorimetric detection of arsenite using polyethylene glycol capped gold nanoparticles—Lab‑on‑chip

Shalvi

1

 · Nitesh Kumar

2

 · Kanak Lata Verma

3

 · Vinod Kumar Jain

2

 · Suman Nagpal

2

Published online: 25 August 2021

© Korean Society of Environmental Risk Assessment and Health Science 2021

Correction to: Toxicology and Environmental Health Sciences https:// doi. org/ 10. 1007/ s13530- 021- 00095-5

Due to an unfortunate oversight during the correction pro- cess, the figures as well as the author name from Shalvi have not been updated.

The author name Shalvi Sharma should be read Shalvi.

The correct figures are as given below (Figs. 2, 5, 6):

The original article has been updated.

The original article can be found online at https:// doi. org/ 10. 1007/

s13530- 021- 00095-5.

* Suman Nagpal snagpal@amity.edu

1 Amity Institute of Forensic Sciences, Amity University, Noida, Uttar Pradesh 201303, India

2 Amity Institute for Advanced Research and Studies (Materials and Devices), Amity University, Noida, Uttar Pradesh 201303, India

3 Regional Forensic Science Laboratory, Home Department, GNCT of Delhi, Chanakyapuri, New Delhi 110021, India

(2)

426 Toxicology and Environmental Health Sciences (2021) 13:425–427

1 3

Fig. 2 a UV–visible spectroscopy spectra of PEG-AuNPs with As (III); b scanning electron microscopy images of bare PEG-AuNPs; c PEG- AuNPs with As (III); d dynamic light scattering of bare PEG-AuNPs

(3)

427 Toxicology and Environmental Health Sciences (2021) 13:425–427

1 3

Fig. 6 Circular representation of interference study of PEG-AuNPs towards other toxic metal ions with reference to As (III)

y = -4x + 935 R² = 0.9589

905 910 915 920 925 930 935

0 1 2 3 4 5 6 7

Devicevalue(a.u.)

Concentration of As(III) (ppm) Device value of PEG-AuNPs with Viscera As(III)

y = 0.079x + 0.882 R² = 0.9676 y = 1.8426x - 1.1907

R² = 0.9945

0 2 4 6 8 10 12

0 2 4 6 8

Absorbance/Devicevalue(a.u)

Concentration (ppm)

Correlation of device v/s Standard methods

UV ICP Linear (UV) Linear (ICP)

Fig. 5 Correlation graph showing relative observation of As (III) in tissue samples via UV–Vis, ICP–OES and fabricated hand-held device

Referenzen

ÄHNLICHE DOKUMENTE

Da sich die Messstelle des AUE in unmittelbarer Nähe zu zwei Bushaltestellen befunden hat, erstaunt es zudem, dass die dort verkehrenden Busse als Lärmquelle offenbar nicht in

Bei den jüngeren Personen (Altersgruppe 61 – 70 Jahre und unter 60 Jahre) fällt der hohe Anteil der männlichen Sondenträger auf. 55,0 % der männlichen Sondenträger waren jünger

Herein, we developed an extremely sensitive and affordable plasmonic immunoassay for respiratory syncytial virus (RSV) detection with the naked eye based on gold

Basierend auf dem gegenwärtigen Kenntnisstand und den Erfahrungen aus der Multi- zenterstudie, kann derzeit festgehal- ten werden, daß die chronische Elek- trotherapie mit

Letztlich sind diese vielfältigen Maßnahmen der Überzeugung ver- pflichtet, daß durch eine ganzheitliche Rehabilitation der Entwicklung psy- chosozialer Störungen begegnet und

Unabhängig von der Indikation findet sich bei älteren Patienten eine relativ hohe Sterblichkeit nach An- lage einer PEG, wie eine Metaana- lyse von Mitchel et al.. Hier fand sich

Since the standard deviation can be used as a quantitative measure of the interface structure, the standard deviation of the chemical composition (intensity) of group V sublattice

On-chip optical mapping using sequence-specific barcoding of DNA molecules, and fabrication of ultra-sensitive integrated micro- and nanofluidic devices for a rapid