~rror Suspected Card Program FEALD FETMM

Im Dokument = == ';' == Maintenance Library (Seite 84-88)

Routine

Code

Function Tested Error Description LOCation(s)

Mask

Page Page Comments

1172 When the storage key is equal to110 and the protect key (L5) is equal to 111, tests that storage protection checks will occur when an attempt is made to modify storage.

OX01 Irpt req grp 1 X'7E' is tested to verify that a protection check A protection check did not occur. A·B4D2

FFFF

CVXXX 6·040

did occur. 6-850

1X16 Pretest error.

1X17 Pretest error.

1X27 Pretest error.

Storage Protection Mechanism Testing at Program L5. Section 4.

The following six routines test to verify that, if the protect key and the storage key are not equal and if the protect key is not equal to zero, the user (L5) is not allowed to modify storage. In addition, protection check should be set.

1173 Test that when the storage key is equal to 100 and the protect key (L5) is equal to 110, storage protection checks will occur when an attempt is made to modify storage.

OX01 Irpt req grp 1 X'7E' is tested to verify that a protection check A protection check did not occur. A·B4D2

FFFF

CVXXX 6·040

did occur. 6·850

1X14 Pretest error.

1X16 Pretest error.

1X26 Pretest error.

1174 When the storage key is equal to 001 and the protect key (L5) is equal to 101, tests that storage protection checks will occur when an attempt is made to modify storage.

OX01 Irpt req grp 1 X'7E' is tested to verify that a protection check A protection check did not occur. A·B4D2

FFFF

CVXXX 6·040

did occur. 6·850

1X11 Pretest error.

1X15 Pretest error.

1X25 Pretest error.

1175 When the storage key is equal to 000 and the protect key (L5) is equal to 100, tests that storage protection checks will occur when an attempt is made to modify storage.

OX01 Irpt req grp 1 X'7E' is tested to verify that a protection check A protection check did not occur. A·B4D2

FFFF

CVXXX 6-040

did occur. 6-850

1X10 Pretest error.

1X14 Pretest error.

1X24 Pretest error.

( " ',-'--"""

/'

. ''j .

"

.

( I~

0

.~ (-" "~

"'i

( ~ ,

r

>. ',,-/'

: I

1,,- . ./ "-~ \..._./ \ . . j \... I

'., ./ ,,--. ..Y '. ./ \" . ./ -.. ,~) ./ ,-,./

{ (/ ( ( ( ( ( ( ( ( (- ( ( ( (/ ( ( ( ( ( « ( (

3705-80 CCU 1FT SYMPTOM INDEX - Cont.

Error Suspected Card Program FEALD FETMM

Routine Code Function Tested Error Description Location(s) Mask Page Page Comments

1177 When the storage key is equal to 011 and the protect key (L5) is equal to 010, tests that storage protection checks will occur when an attempt is made to modify storage.

OX01 Irpt req grp 1 X'7E' is tested to verify that a protection check A protection check did not occur. A-B4D2

FFFF

CVXXX 6-040

did occur. 6-850

1X12 Pretest error.

1X13 Pretest error.

1X22 Pretest error.

1178 When the storage key is equal to 101 and the protect key (L5) is equal to 001, tests that storage protection checks will occur when an attempt is made to modify storage.

OX01 Irpt req grp 1 X'7E' is tested to verify that a protection check A protection check did not occur. A-B4D2

FFFF

CVXXX 6-040

did occur. 6-850

1X11 Pretest error.

1X15 Pretest error.

1X21 Pretest error.

1179 When the storage key is equal to 100 and the protect key (L51 is equal to 111, tests that storage protection checks will occur when an attempt is made to modify storage.

OX01 Irpt req grp 1 X'7E' is tested to verify that a protection check A protection check did not occur A-B4D2

FFFF

CVXXX 6-040

did occur. 1-040

1X14 Pretest error.

1X17 Pretest error.

1X27 Pretest error.

,

r

'-. /

~rror

Routine Code Error Description

Suspected Card Location(s)

Program Mask

FEAlD Page 1190

'---j

')

The customer usage meter should run when an instruction is executed at program levels 1,2,4,5, and L3 if 8 ms has elapsed since the interval timer irpt occurred or if an instruction is executed at L3 and a non-interval timer irpt has occurred_

A series of instructions totaling 24 seconds will be executed on each level for a total run time of 2 ,minutes (0.034 run time on meter).

You will be requested to read and enter the meter at the start of the test and at the end. As a result, this routine will run only if the manual intervention CE sense switch is set.

e Customer Usage Meter Test 1

Enter the meter reading as follows (see Figure 1190):

1_ When code FX01 is displayed in DISPLAY

a,

set the DISPLAY/FUNCTION SELECT switch to FUNCTION 5.

2. Ignoring the three leftmost meter positions, enter the remaining positions in STORAGE ADDRESS/REGISTER DATA switches B, C, D, and E. Note that the value entered in switch E represents the marks on the rightmost meter wheel (thousands position). Always round the thousands position to the nearest even number (2,4,6,8,0).

3. Press the START pushbutton. '

4. When code FX02 is displayed in DISPLAY

a,

enter the new meter reading in the STORAGE ADDRESS/REGISTER DATA switches B, C, D, and E as described in step 2.

5. Press the START pushbutton.

EX01 FX02 OX01

f - ' "

"-f'

, - - Enter Value in switch B

+..---

Enter value in switch 0

o 4 2

1

=

3 1 ~

I---Enter value of the mark (2,4,6,8,0) in switch E

~--~ ..

--~----~--~-L

Enter value in switch C

" " - . . - '

Ignore these positions

For this example you would enter 1 3 1 0 in switches B, C, D. and E Figure 1190. How to Read the Metarfor Test Routina 1190.

Display code to indicate that this routine is running (2 min.).

Manual intervention code. Enter the meter value observed in step 4 above.

The first meter reading is updated by 0.034 and compared with the second reading to verify that the run time is two minutes (0.034 in terms of meter reading).

The meter fail to run correctly or meter reading were not consistent.

r , \ ''\ (~ r~

r "\

0

j '",j , , - , j "'--_/

'--",-j "- / / " j "~ / '- ,---",j

'--N/A

A-B3 L2 A-B3 M2

/ \

, , - j

'\

'-- /

"-N/A N/A FFFF

'\

/ '-.. .. - /

N/A

CP006 CP007

1",\

' \

j

FETMM Page

1-040

1-040

-..-/1 /

Comments

1-040

Warning: If the meter reading entered under FX01 was between 9.966 and 9.999 inclusive a false error will be reported. Rerun the test again.

"

" 7~

; '

,

(

\,-,~ '---/

( ( ( ( ( ( ( ( ( ( ( ( « ( ( ( (- (

3705-80 CCU 1FT SYMPTOM INDEX - Cont.

Error Suspected Card Program FEALD FETMM

Routine Code Function T

es:bIaI

Error Description Location(s) Mask Page Page Comments

1191 Customer usage meter test 2. If no other program levels are active 1-040

and an L3 interval timer irpt occurs, the customer usage meter should not run until after 8 ms has elapsed. This routine will mask off all execution except the interval timer and update a real time type of count. The customer usage meter should not run during this routine.

Run time is 1 minute.

FX01 Same as FX01 above.

EX02 Displays code to indicate this routine is running. N/A N/A N/A

FX02 Same as FX02 above.

OX01 The first meter reading is saved and compared with the second. The meter either ran or meter readings were not consistent. A-B3 L2 FFFF CP006 1-040

Since the meter should not run, the two meter readings should A-B3 M2 CP007

be equal.

Pretest Error Codes

The following error codes define failures of functions previously tested by other routines. For each error code a cross reference will be given to point to the routine that originally tested the given function.

11XX 1X01 Forces an L3 irpt via an output X'7C' to set PCI L3. L3 irpt failed to occur N/A 6-940 Routine 1113 previously tested this function.

Request routine 1113 and verify that PCI L3 will force an L3 irpt.

11XX 1X02 Forces an L2 irpt via an output to set diag L2 irpt. L2 irpt failed to occur. N/A 6~900 The DCM set the L2 mask before loading a given I FT. As a result, L2 must be unmasked before focusing an L2 irpt. Routine 1115 test both the unmasking of L2 irpt and masking of L2 irpt via an output to set diag L2.

11XX 1X03 Forces an irpt via an invalid output reg X'2F'. L 1 irpt failed to occur. N/A 6-050 Routine 1118 previously tested this function.

Request routine 1118 and verify if an L 1 irpt can be forced via an I/O check.

11XX 1X10 Sets a given storage key to 000. Key failed to set. N/A 6-040 See Notes 2 and 5. Routine 1146 previously tested

6-880 this function. Run routine 1146 or 1156.

11XX 1X11 Sets a 'given storage key to 001. Key failed to set. N/A 6-040 See Notes 2 and 5. Routine 1147 previously tested

6-880 this function. Run routine 1147 or 1156.

11XX 1X12 Sets a given storage key to 010. Key failed to set. N/A 6-040 See Notes 2 and 5. Routine 1148 tested this

func-6-880 tion. Run routine 1148 or 1156.

11XX 1X13 Sets a given storage key to 011. Key failed to set. N/A 6-040 See Notes 2 and'5. Routine 1149 previously tested

6-880 this function. Run routine 1149 or 1156.

11XX 1X14 Sets a given storage key to 100. Key failed to set. N/A 6-040 See Notes 2 and 5. Routine 114A previously tested

6-880 this function. Run routine 114A or 1156.

...