• Keine Ergebnisse gefunden

[1] Albert E. Zur Resektion des Kniegelenks. 1879. Wien Med Press. 20: 705-708.

[2] Amiot, L.P., Lang, K., Putzier, M., Zippel, H, and Labelle, H. Comparative Results Between Conventional and Computer-Assisted Pedicle Screw Installation in the Thoracic, Lumbar, and Sacral Spine. Spine, 2000. 25(5): p. 606-614.

[3] Amstutz, C. and Nolte, L.P. Application accuracy of linear stereotactic tools. in 4th international symposium on CAOS. 1999. Davos.

[4] Amstutz, C., Kowal, J., and Nolte, L.P. A novel concept to track deformable tools in image-based registration. in 1st Annual Meeting CAOS: Computer Assisted Orthopaedic Surgery. 2001.

Davos.

[5] Anderson, T., Montgomery, F., Carlsson, A. Uncemented STAR Total Ankle Prostheses. The Journal of Bone and Joint surgery. 2003. 85A(7): 1321-1329.

[6] Arand, M., Kinzl, L., Gebhard, F. Fehlerquellen und Gefahren der CT-basierten Navigation, Der Orthopäde. 2002. 31(4): 378-384.

[7] Arand, M., Schempf, M., Hebold, D., Teller, S., Kinzl, L., Gebhard, F. Präzision der navigationsgestützten Chirurgie an der Brust- und Lendenwirbelsäule. Der Unfallchirurg. 2003.

106(11): 899-906.

[8] Bächler, R. Oberflächenbasierte Registrierung für orthopädische und HNO-Anwendungen. in Philosophisch-naturwissenschaftliche Fakultät. 2000. Universität Bern: Bern, Switzerland. p.

114.

[9] Bauer, G., Kinzl, L. Arthrodesen des oberen Sprunggelenks. Der Orthopäde. 1996. 25: 158-165.

[10] Berlemann, U., Langlotz, F., Langlotz, U., Nolte, L.P. Computerassistierte Orthopädische Chirurgie (CAOS). Der Orthopäde. 1997. 26(5): 463-469.

[11] Böhler, L. Die Technik der Knochenbruchbehandlung,1957, Band II/2, 10-13, Maudrich, Wien

Bone and Joint Surgery. 67B(5): 785-790.

[13] Bös, L., Ellermann, A. Arthroskopische Diagnostik und Klassifikation von Knorpelschäden.

Deutsche Zeitschrift für Sportmedizin. 2003. 54 (6): 181-183.

[14] Breitfuß, H., Muhr, G., Mönning, B. Fixateur oder Schraube bei Arthrodesen am oberen Sprunggelenk, 1989, Unfallchirurgie 92: 245-253

[15] Buchner, M., Sabo, D. Ankle Fusion Attributable to Posttraumatic Arthrosis: A Long-Term Followup of 48 Patients. Clinical Orthopaedics an Related Research. 2003. 406: 155-164.

[16] Buck, P., Morrey, B.F., Chao, E.Y. The optimum position of arthrodesis of the ankle. A gait study of the knee and ankle. Journal of Bone and Joint Surgery. 1987. 69(7): 1052-1062.

[17] Castro, W.H., Halm, H., Jerosch, J., Malms, J., Steinbeck, J., and Blasius, S., Accuracy of pedicle screw placement in lumbar vertebrae. Spine, 1996. 21(11): p. 1320-4.

[18] Charnley, J. Compression arthrodesis of the ankle and shoulder, 1951, J Bone Joint Surg 33B, 180

[19] Chassat, F., Lavallée, S. Experimental protocol of accuracy evaluation of 6-D localizers for computer-integrated surgery: application to four optical localizers. in Proceedings of the First International Conference on Medical image computing and computerassisted intervention -MICCAI `98. 1998. Berlin Heidelberg: Springer.

[20] Cinotti, G., Gumina, S., Ripani, M., and Postacchini, F., Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine, 1999. 24(2): p. 114-9.

[21] Citak, M., Hüfner, T., Geerling, J., Kfuri, M. jr., Gänsslen, A., Look, V., Kendoff, D., Krettek, C.

Navigated percutaneous pelvic sacroiliac screw fixation: experimental comparison of accuracy between fluoroscopy and Iso-C3D navigation. Computer Aided Surgery. 2006. 11(4): 209-213.

[22] Coester, L.M., Saltzman, C.L., Leupold, J., Pontarelli, W. Long-Term Results Following Ankle Arthrodesis For Post-Traumatic Arthritis. Journal of Bone and Joint Surgery. 2001. 83A(2): 219-228.

[23] Conti, S.F., Wong, Y.S. Complications of Total Ankle Replacement. Clinical Orthopaedics and Related Research. 2001. 391: 105-114.

[24] Cracchiolo, A., Cimino, W.R., Lian, G. Arthrodesis of the ankle in patients who have rheumatoid arthritis. Journal of Bone and Joint Surgery. 1992. 74(6): 903-909.

[25] Danis, R. Théorie et pratique de l’ostéosynthèse, 1949, Desoer et Masson, Liège

[26] Dreyer, R. Sportbootführerschein See. Delius Klasing. 2003. S. 25.

[27] Felix, N.A., Kitaoka, H.B. Ankle Arthrodesis in Patients With Rheumatoid Arthritis. Clinical Orthopaedics and Related Research. 1998. 349: 58-64.

[28] Feneis, H. Anatomisches Bildwörterbuch der internationalen Nomenklatur, Thieme 1993

[29] Fritsch, E., Duchow, J., Seil, R., Grunnwald, I., Reith, W. Genauigkeit der fluoroskopischen Navigation von Pedikelschrauben. Der Orthopäde. 2002. 31(4): 385-391.

[30] Gautier, E., Bächler, R., Heini, P.F., Nolte, L.P. Accuracy of Computer-Guided Screw Fixation of the Sacroiliac Joint. Clinical Orthopaedics and Related Research. 2001. 393: 310-317.

[31] Gebhard, F., Arand, M., Fleiter, T., Hebecker, A., Heeckt, P., Hesser, J., Messmer, P., Hüfner, T., Visarius, H., Regazzoni, P., Kinzl, L. Computer assistierte Chirurgie, Entwicklung und Perspektiven 2001. Der Unfallchirurg. 2001. 104(8): 782-788.

[32] Gebhard, F., Kinzl, L., Arand, M. Grenzen der CT-basierten Computernavigation in der Wirbelsäulenchirurgie. Der Unfallchirurg. 2000. 103(8): 696-701.

[33] Gebhard, F., Weidner, A., Liener, U.C., Stöckle, U., Arand, M. Navigation at the spine. Injury.

2004. 35(Suppl.): S-A35-S-A45.

[34] Gong, J.X., R, B., M, S., and Nolte LP, Restricted Surface Matching - A New Approach for Registration in CAS, in CVRMed-MRCAS´97., Troccaz J, Grimson E, and R, M., Editors. 1997, Springer-Verlag: Berlin, Heidelberg, New York. p. 597-605.

[35] Gruen, G.S., Mears, D.C. Arthrodesis of the ankle and subtalar joints, 1991, Clinical Orthopaedics and Related Research. 268: 15-20

[36] Grützner, P.A., Beutler, T., Wendl, K., Recum, J. von, Wentzensen, A., Nolte, L.P. Navigation an der Brust- und Lendenwirbelsäule mit dem 3D-Bildwandler. Der Chirurg. 2004. 75(10): 967-975.

[37] Grützner, P.A., Hebecker, A., Waelti, H., Vock, B., Nolte, L.P., Wentzensen, A. Clinical Study for Registration-Free 3D-Navigation with the SIREMOBIL Iso-C-3D Mobile C-Arm.

[38] Hawkins, B.J., Langermann, R.J., Anger, D.M., Calhoun, J.H. The Ilizarov technique in ankle fusion. Clinical Orthopaedics and Related Research. 1994. 303: 217-225.

[39] Hellemondt, G. van, Kleuver, M. de, Kerckhaert, A., Anderson, P., Langlotz, F., Nolte, L.P., Pavlov, P.W. Computer-Assisted Pelvic Surgery. Clinical Orthopaedics and Related Research.

2002. 405: 287-293.

[40] Herring, J.L., Dawant, B.M., Maurer, C.R., Muratore, D.M., Galloway, R.L., and Fitzpatrick, J.M., Surface-based registration of CT images to physical space for image-guided surgery of the spine: a sensitivity study. IEEE Trans Med Imaging, 1998. 17(5): p. 743-52.

[41] Hinsche, A.F., Giannoudis, P.V., Smith, R.M. Fluoroscopy-Based Multiplanar Image Guidance for Insertion of Sacroiliac Screws. Clinical Orthopaedics and Related Research. 2001. 395: 135-144.

[42] Hintermann, B. Die STAR-Sprunggelenkprothese. Kurz- und mittelfristige Erfahrungen. Der Orthopäde. 1999. 28(9): 792-803.

[43] Holz, U. Die Arthrodese des oberen Sprunggelenks mit Zugschrauben in: Operative Orthopädie und Traumatologie 2(2), 1990, 131-138.

[44] Horn, B.K. Closed-form Solution of Absolute Orientation Using Unit Quaternions. J Optical Society Am, 1987. 4(629-642).

[45] Hounsfield, G.N., Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol, 1973. 46(552): p. 1016-22.

[46] Hüfner, T., Citak, M., Gänsslen, A., Bazak, N., Rosenthal, H., Pohlemann, T. Registration using a modified external fixateur system for the pelvis. in 5th International Symposium on CAOS.

2000. Davos.

[47] Hüfner, T., Gebhard, F., Grützner, P.A., Messmer, P., Stöckle, U., Krettek, C. Which navigation when? Injury. 2004. 35(Suppl.): S-A30-S-A34.

[48] Hüfner, T., Geerling, J., Gänsslen, A., Kendoff, D., Citak, M., Grützner, P.A., Krettek, C.

Rechnergestütztes Operieren bei Beckenverletzungen. 2004. Der Chirurg. 75(10): 961-966.

[49] Hüfner, T., Geerling, J., Oldag, G., Richter, M., Kfuri, M. jr., Pohlemann, T., Krettek, C.

Accuracy study of computer-assisted drilling: the effect of bone density, drill bit characteristics, and use of a mechanical guide. Journal of Orthopaedic Trauma. 2005. 19(5): 317-322.

[50] Hüfner, T., Kfuri, M. jr., Kendoff, D., Richter, M., Geerling, J., Krettek, C. Navigierte Osteosynthese des proximalen Femurs. Der Unfallchirurg. 2003. 106(11): 975-979.

[51] Jacob, A.L., Messmer, P., Kaim, A., Suhm, N., Regazzoni, P., and Baumann, B., A whole-body registration-free navigation system for image-guided surgery and interventional radiology. Invest Radiol, 2000. 35(5): p. 279-88.

[52] Kahler DM, Zura RD, and Mallik K. Computer guided placement of iliosacral screws compared to standard fluoroscopic technique. in 5th Symposium on CAOS Computer Assisted Orthopaedic Surgery. 2000. Davos.

[53] Kalender WA, Computertomographie. 2000, München: Publicis MCD Werbeagentur GmbH.

216.

[54] Kapandji, I. A. Funktionelle Anatomie der Gelenke, Hippokrates 1984

[55] Kendoff, D., Hüfner, T., Citak, M., Maier, C., Wesemeier, F., Pearle, A., Krettek, C. Eine neue Doppelbohrbüchse zur navigierten Schenkelhalsverschraubung. Entwicklung und Evaluation.

Der Unfallchirurg. 2006. 109(10): 875-880.

[56] Khadem, R., Yeh, C.C., Sadeghi-Tehrani, M., Bax, M.R., Johnson, J.A., Welch, J.N., Wilkinson, E.P., and Shahidi, R., Comparative tracking error analysis of five different optical tracking systems. Comput Aided Surg, 2000. 5(2): p. -1

[57] Kitaoka, H.B., Alexander, I.J., Adelaar, R.S., Nunley, J.A., Myerson, M.S., Sanders, M. Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot and Ankle International. 1994. 15(7): 349-353.

[58] Kitaoka, H.B. Salvage of nonunion following ankle arthrodesis for failed total ankle arthroplasty, 1991, Clin Orthop 268: 37-43

[59] Kitaoka, H.B., Patzer, G.L. Arthrodesis for the Treatment of Arthrodesis of the Ankle and Osteonecrosis of the Talus. Journal of Bone and Joint Surgery. 1998. 80A(3): 370-379.

[60] Kitaoka, H.B., Patzer, G.L. Clinical Results of the Mayo Total Ankle Arthroplasty. Journal of Bone and Joint Surgery. 1996. 78A(11): 1658-1664.

[61] Kofoed, H. Scandinavian Total Ankle Replacement (STAR). Clinical Orthopaedics and Related Research. 2004. 424: 73-79.

[62] Krämer, K.L., Maichl, F.P. Scores, Bewertungsschemata und Klassifikationen in Orthopädie und

[63] Laine, T., Lund, T., Ylikoski, M., Lohikoski, J., Schlenzka, D. Accuracy of pedicle srew insertion with and without computer assistance - A randomized controlled clinical study in 100 consecutive patients. in CAOS Computer Assisted Orthopaedic Surgery. 2000. Davos, Switzerland.

[64] Laine, T., Schlenzka, D., Mäkitalo, K., Tallroth, K., Nolte, L.P., Visarius, H. Improved Accuracy of Pedicle Screw Insertion With Computer-Assisted Surgery. Spine. 1997. 22(11): 1254-1258.

[65] Langlotz, F., Bächler, R., Berlemann, U., Nolte, L.P., Ganz, R. Computer Assistance for Pelvic Osteotomies. Clin Orthop, 1998. 354: p. 92-102.

[66] Langlotz, F., Davies, B.L., Bauer, A. Computer assisted orthopaedic surgery, 3rd annual meeting of CAOS-international proceedings, Steinkopff 2003

[67] Langlotz, F., Davies, B.L., Stulberg, S.D. Computer assisted orthopaedic Surgery, 4th annual meeting of CAOS-internetional proceedings 2004

[68] Langlotz, F., Stucki, M., Bächler, R., Ganz, R., Nolte, L.P. The first twelve cases of computer assisted periacetabular osteotomy. Comput Aided Surg, 1997. 2: p. 317-326.

[69] Langlotz, U., Langlotz, F., Hiogne, D., Rohrer, U., Nolte, L.P. A novel system for complete THR planning and intraoperative free-hand navigation. in CAOS Computer Assisted Orthopaedic Surgery. 2000. Davos, Switzerland.

[70] Lavallée, S., Troccaz, J., Sautot, P., Mazier, B., Cinquin, P., Merloz, P., Chirossel, J.P.

Computer-assisted Spine Surgery Using Anatomy-based Registration., in Computer-Integrated Surgery, Taylor R, Lavallée S, Burdea G, and Moesges R, Editors. 1996, MIT Press: Cambridge [71] Lavallée, S., Registration for Computer-Integrated Surgery: methodology, State of the Art., in

Computer-Integrated Surgery, Technology and Clinical Applications., R. Taylor, Lavallee, S., Burdea GC, and Mösges R, Editors. 1996, MIT press: Cambridge. p. 77-97.

[72] Lavallée, S., Sautot, P., Troccaz, J., Cinquin, P., and Merloz, P., Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer. J Image Guid Surg, 1995. 1(1): p. 65-73.

[73] Lord, G., Marotte, J.H. Total ankle prosthesis. Technic and 1st results. Apropos of 12 cases.

Revue de chirurgie orthopédique et reparatrice de l’ appareil moteur. 1973. 59(2): 139-151.

[74] Maciunas, R.J., Galloway, R.L., Jr., and Latimer, J.W., The application accuracy of stereotactic frames. Neurosurgery, 1994. 35(4): p. 682-94; discussion 694-5.

[75] Malgaigne, J., Traites des fractures et des luxations. 1847, Paris: J.B. Balliere.

[76] Mc Guire, M.R., Kyle, R.F., Gustilo, R.B., Premer, R.F. Comparative analysis of ankle arthroplasty versus ankle arthrodesis, Clinical Orthopaedics and Related Research. 1988. 226:

174-181

[77] Merloz, P., Tonetti, J., Cinquin, P., Lavalleé, S., Troccaz, J., Pittet, L. Chirurgie assistée par ordinateur: vissage automatisé des pédicules vertébraux. Chirurgie. 1998. 123: 482-490.

[78] Merloz, P., Tonetti, J., Eid, A., Faure, C., Lavalleé, S., Troccaz, J., Sautot, P., Hamadeh, A., Cinquin, P. Computer Assisted Spine Surgery. Clinical Orthopaedics and Related Research.

1997. 337: 86-96.

[79] Merloz, P., Tonetti, J., Pittet, L., Coulomb, M., Lavalleé, S., Sautot, P. Pedicle Screw Placement Using Image Guided Techniques. Clinical Orthopaedics and Related Research. 1998. 354: 39-48.

[80] Messerer, O., Über Elasticität und Festigkeit der menschlichen Knochen. 1880, Stuttgart: Verlag der J.G. Cotta'schen Buchhandlung.

[81] Messmer, P., Jacob, A.L., Fries, E., Gross, T., Suhm, N., Steinbrich, W., Frede, K.E., Schneider, T., Regazzoni, P. Technologieintegration und Prozessmanagement. Der Unfallchirurg. 2001.

104(10): 1025-1030.

[82] Mittelmeier, H., Hort, W., Diehl, K. Internal compression arthrodesis of the ankle joint (with examination of stability for comparison). Archiv für orthopädische und Unfallchirurgie. 1975.

81(1): 57-64.

[83] Müller, E.J., Wick, M., Muhr, G. Chirurgische Therapie bei Inkongruenzen und Arthrosen am oberen Sprunggelenk. Der Orthopäde. 1999. 28(6): 529-537.

[84] Müller, M., Manual der Osteosynthese. 1 ed, ed. E. Müller, Allgöwer, M., and Willenegger, H.

Vol. 1st Edition. 1967, Berlin Heidelberg New York: Springer-Verlag.

[85] Nolte, L.P., Zamorano, L.J., Jiang, Z., Wang, Q., Langlotz, F., Arm, E., Visarius, H. A Novel Approach to Computer Assisted Spine Surgery. in Proc 1st Int Symp on Medical Robotics and Computer Assisted Surgery (MRCAS). 1994.

[86] Olerud, C., Molander, H.A. Scoring scale for symptoms evaluation after ankle fractures, Arch Orthop Trauma Surg, 103, 190-194, 1984

[87] Orthner, E. Arthroskopie des oberen Sprunggelenks. Unfallchirurg 2000, Oct, 103(10):858 - 63

[88] Orthopedic Trauma Association Committee for coding and classification, Fracture and dislocation compendium. J Orthop Trauma, 1996. 10(Suppl 1): p. V-IX.

[89] Outerbridge, R.E. The Etiology of Chondromalacia Patellae. Journal of Bone and Joint Surgery.

1961. 43B (4): 752-757.

fusion. Archive of Orthopaedic and Traumtological Surgery. 1996. 115: 146-148.

[91] Pförringer, W., Stolz, P. Die Behandlung der frischen fibularen Kapselbandläsion.

Sportverletzung Sportschaden. 1991. 5: 142-148

[92] Picard, C., Olivier, A., and Bertrand, G., The first human stereotaxic apparatus. The contribution of Aubrey Mussen to the field of stereotaxis. J Neurosurg, 1983. 59(4): p. 673-6.

[93] Pierre, A., Hulet, C., Locker, B., Souquet, D., Jambou, S., Vielpeau, C. Arthrodèse tibio-talienne sous contrôle arthroscopique: limites et indications. Masson. 2002. 89(2): 144-151.

[94] Platzer, W. Bd. 1 Bewegungsapparat, Taschenatlas der Anatomie, Thieme 1986

[95] Press, W.H., Teukolsky, S.A., Vettrerling, W.T., Flannery, B.P. Numerical Recipes in C: The Art of Scientific Computing. Cambridge University Press, 1988.

[96] Pyevich, M.T., Saltzman, C.L., Callaghan, J.J., Alvine, F.G. Total Ankle Arthroplasty: a Unique Design. Journal of Bone and Joint Surgery. 1998. 80A(10): 1410-1420.

[97] Regazzoni, P., Jacob, A.L., and Messmer, P., CT Navigation Becken. 2000, Arbeitstagung Reisenburg CAS: Ulm.

[98] Richter, M. Experimental Comparison Between Computer Assisted Surgery (CAS) Based and C-Arm Based Correction of Hind- and Midfoot Deformities. Osteo Trauma Care. 2003. 11:29-34.

[99] Richter, M., Amiot, L.P., Puhl, W. Computernavigation bei der dorsalen Instrumentierung der HWS – eine In-vitro-Studie. Der Orthopäde. 2002. 31(4): 372-377

[100] Riede, U.-N., Schäfer, H.-E. Allgemeine und spezielle Pathologie. Thieme. 1999. S.1145-1154.

[101] Röntgen, C. Vorläufige Mitteilung über eine neue Art von Strahlen. Physikalisch-medizinische Gesellschaft von Würzburg, 1895.

[102] Schlenzka, D., Laine, T., Lund, T. Computerunterstützte Wirbelsäulenchirurgie. Der Orthopäde.

2000. 29(7): 658-669.

[103] Schnake, K.J., König, B., Berth, U., Schroeder, R.J., Kandziora, F., Stöckle, U., Raschke, M., Haas, N.P. Genauigkeit der CT-basierten Navigation von Pedikelschrauben an der Brustwirbelsäule im Vergleich zur konventionellen Technik. Der Unfallchirurg. 2004. 107(2):

104-112.

[104] Schneider, J., Risikomanagement in der Medizintechnik. Methodik zur Überprüfung der geometrischen Genauigkeit CT-basierter Verfahren in der computer-unterstützten Therapie., Dissertationsschrift der Medizinischen Fakultät. 2000, Friedrich-Alexander-Universität:

Erlangen-Nürnberg. p. 87.

Schreiner, S., Galloway, R.L., Lewis, J.T., Bass, W.A., and Muratore, D.M., An ultrasonic approach to localization of fiducial markers for interactive, image-guided neurosurgery--Part II:

Implementation and automation. IEEE Trans Biomed Eng, 1998. 45(5): p. 631-41.

[105] Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.P., Ozdoba, C. Accuracy of Computer-Assisted Pedicle Screw Placement. Spine. 1997. 22(4): 452-458.

[106] Smet, M. Threedimensional skeletal visualization with spiral computed tomography, in Medical Dept. 1999, University of Leuven: Leuven.

[107] Stöckle, U., König, B., Schaser, K., Melcher, I., Haas, N.P. CT- und fluoroskopiebasierte Navigation in der Beckenchirurgie. Der Unfallchirurg. 2003. 106(11): 914-920.

[108] Stuhler, T. Arthrodesen, Thieme 1994

[109] Suhm, N., Messmer, P., Zuna, I., Jacob, L.A., Regazzoni, P. Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study. Injury. 2004. 35: 567-574.

[110] Syme, J. Contributions to the pathology and practice of surgery, 1848, Sutherland and Knox, Edinburgh

[111] Takakura, Y., Tanaka, Y., Sugimoto, K., Akiyama, K., Tamai, S. Long Term Results of Arthrodesis for Osteoarthritis of the Ankle. Clinical Orthopaedics and Related Research. 1999.

361: 178-185.

[112] Thermann, H., Hüfner, T., Roehler, A., Tscherne, H. Schraubenarthrodese des oberen Sprunggelenks. Technik und Ergebnisse. Der Orthopäde. 1996. 25: 166-176.

[113] Thermann, H., Krettek, C. Sprunggelenksendoprothetik. Der Unfallchirurg. 2002. 105(6): 495.

[114] Thermann, H., Saltzman, C.L. Endoprothetischer Ersatz des oberen Sprunggelenks. Der Unfallchirurg. 2002. 105(6): 496-510.

Joint Surgery. 2003. 85A(5): 923-936.

[116] Tillmann, K. Endoprothetik am oberen Sprunggelenk. Indikation, Entwicklung, aktueller Stand und Trends. Der Orthopäde. 2003. 32(2): 179-187

[117] Tonetti, J., Carrat, L., Lavalleé, S., Pittet, L., Merloz, P., and Chirossel, J.P. Percutaneous Iliosacral Screw Placement Using Image Guided Techniques. Clinical Orthopaedics and Related Research. 1998. 354: p. 103-110.

[118] Trieb, K., Lack, W. Die minimalinvasive Arthrodese des oberen Sprunggelenks mittels spongiosagefüllter Titanschraubzylinder. Z Orthop. 1999. 137: 79-82.

[119] Tscherne, H. Unfallchirurgie in 12 Bänden, Bd. Fuß, Springer 1997.

[120] Wagner, H., Pock, H.G. Die Verschraubungsarthrodese der Sprunggelenke, 1982, Unfallheilkunde 85: 280-300

[121] Wallny, T., Klose, J., Steffny, G., Schulze Bertelsbeck, D., Perlick, L., and Schumpe, G., [Three-dimensional ultrasonography and intraoperative navigation:a new application of ultrasonograms in osteotomy of the proximal femur]. Ultraschall Med, 1999. 20(4): p. 158-60.

[122] Wendl, K., Recum, J. von, Wentzensen, A., Grützner, P.A. Iso-C-3D- gestützte navigierte Implantation von Pedikelschrauben an BWS und LWS. Der Unfallchirurg. 2003. 106(11): 907-913.

[123] Wirth, C.J. (Hrsg.), Orthopädie und orthopädische Chirurgie, Band: Fuß, Thieme 2002

[124] Wülker, N., Flamme, C.H., Müller, A., Wirth, C.J. Z Orthop. 1997. 135: 509-515.

[125] Zimmermann, H. Die Schraubenarthrodese des oberen Sprunggelenks. Orthop. Praxis 10 (1973), 426

[126] Zwipp, H. Chirurgie des Fußes, Springer 1994.

[127] Zwipp, H., Gotzen, L., Krettek, C. Die Kompressionsarthrodese des oberen Sprunggelenks:

Indikation, OP-Technik und Ergebnisse. 1984. In: Rahmanzadeh R, Faensen M (Hrsg.)

Posttraumatische Fehlstellungen der unteren Extremität. Schetztor, Konstanz, S.106

[128] Zwipp, H., Grass, R., Rammelt, S., Dahlen, C. Arthrodese – Pseudarthrosen am Sprunggelenk.

Der Chirurg. 1999. 70: 1216-1224.

7.2 Tabellen

Auflistung der untersuchten Kadaver-Tali ... 5

Klassifikation des Knorpelschadens [13][89]... 9

Klassifikation der Arthrose am OSG (Pförringer und Stolz) [91] ... 10

Komplikationen der Arthrodese... 12

Schrauben nach Punktwert sortiert ... 80

Punktwerte navigiert vs. nicht navigiert ... 81

Punktwerte nach Schrauben (navigiert) ... 82

Punktwerte nach Schrauben (nicht navigiert) ... 82

Punktwert Kadaver-OSGs navigiert vs. nicht navigiert... 83

Summe der Punktwerte der Kadaver-OSGs navigiert vs. nicht navigiert ... 83

Punktwert für die 4 verschiedenen Schrauben (navigiert)... 84

Punktwert für die 4 verschiedenen Schrauben (nicht navigiert)... 84

Punktwerte aller Schrauben ... 85

Punktwerte aller Schrauben navigiert vs. nicht navigiert ... 85

Punktwerte der 4 navigierten Schrauben ... 86

Punktwerte der 4 nicht navigierten Schrauben ... 86

Punktwerte der 4 Schrauben insgesamt ... 87

Punktwerte der Arthrodesen nach Schrauben ... 87

Revisionen fehlerhaft gesetzter Schrauben... 94

Punktwert navigiert vs. nicht navigiert ... 94

Punktwert Kunststoff vs. Kadaver ... 95

Punktwert aufgeschlüsselt nach Schrauben ... 96

Zeit navigiert vs. nicht navigiert ... 96

Zeit Kunststoff vs. Kadaver ... 97

Zeit aufgeschlüsselt nach Schrauben ... 97

Der zu bevorzugende Bohrer mit der durch die Farbe angegebenen Abweichung ... 106

Abweichungen am Plexiglasquader... 59

Abweichungen [mm] am Plexiglasquader nach Durchmesser ... 60

Bohrerlängen aufsteigend geordnet ... 60

Mittlere Abweichungen [mm] am Plexiglasquader nach Bohrerlänge geordnet... 61

Rangfolge aller Bohrer am Plexiglasquader ... 61

Abweichung [mm] am Spongiosaquader für alle Bohrer ... 62

Abweichung [mm] Exit Spongiosa nach Durchmesser ... 63

Abweichung an Spongiosaquadern für 2,5mm-Bohrer ... 63

Abweichungen an Spongiosaquadern für 3,2mm-Bohrer... 64

Abweichungen an Spongiosaquadern für 3,5mm-Bohrer... 64

Abweichungen an Spongiosaquadern für 4,5mm-Bohrer... 65

Abweichung [mm] Exit Spongiosa nach Bohrerlänge... 65

Abweichungen bis 150mm Bohrerlänge... 66

Abweichungen bis 185 mm Bohrerlänge... 67

Abweichung bis 230 mm Bohrerlänge ... 68

Abweichungen bis 260 mm Bohrerlänge... 68

Bohrer geordnet nach Größe der Abweichung [mm] ... 70

Vergleich für alle Bohrer (p=0,0) ... 70

Vergleich der Abweichungen nach Durchmesser... 70

Vergleich der Abweichungen über alle Bohrerlängen... 71

Vergleich für alle Bohrer ... 71

Vergleich Plexiglas- zu Spongiosaquader ... 72

Vergleich Plexiglas- zu Spongiosaquader nach Durchmesser... 73

Vergleich Plexiglas- zu Spongiosaquader nach Bohrerlängen ... 73

Vergleichende Rangfolge Plexiglas- und Spongiosaquader ... 74

Vergleich über alle Bohrer nach Bohrkanallänge... 74

Vergleich aller Bohrer über Bohrkanallänge 50mm... 75

Vergleich aller Bohrer über Bohrkanallänge 100mm... 75

Vergleich (aller) Bohrer über Bohrkanallänge 150mm ... 76

Abweichungen [mm] für Bohrer mit 2,5 mm Durchmesser... 77

Abweichungen [mm] für Bohrer mit 3,2 mm Durchmesser... 77

Abweichungen [mm] für Bohrer mit 3,5 mm Durchmesser... 78

Abweichungen [mm] für Bohrer mit 4,5 mm Durchmesser... 78

Zeitdauer [min] für Kunststoff- und Kadaver-Arthrodesen... 88

Zeit [min] für alle Schrauben... 89

Zeit [min] für Arthrodesen am Kunst-Knochen ... 89

Zeit [min] für Arthrodesen am Kadaver-Knochen... 90

Zeit [min] für navigierte Arthrodesen... 90

Zeit [min] für nicht navigierte Arthrodesen... 91

Zeit [min] für alle navigierten Schrauben... 91

Zeit [min] für alle nicht navigierten Schrauben... 92

Zeit [min] unter Bestrahlung... 93

7.4 Abbildungen

Querversetzung eines Schiffes... 1

Der Sextant ... 2

Auflagepunkte der Fußsohle [54] Fußsohle im Schema [54] ... 3

Rechter Talus von oben [94] Rechter Talus von unten [94]... 4

Bewegungsachsen am Fuß [54] ... 6

Ansicht von medio-posterior [54] Ansicht von latero-posterior [54] ... 8

Schraubenarthrodesen des oberen Sprunggelenkes mit 2 bis 5 Schrauben [123]... 14

Schema verschiedener Schraubenarthrodesen über unterschiedliche Gelenke[123]... 16

Schraubenarthrodese nach Zwipp [127][128][126]... 17

3-D-Schablone von der „entry“-Seite aus gesehen... 36

3-D-Schablone von der „exit“-Seite (Zielpunkte) aus gesehen ... 37

Übersicht über den Versuchsaufbau mit abgedeckter 3-D-Schablone ... 38

Übersicht des Versuchsaufbaus, zur besseren Verständlichkeit nicht abgedeckt... 38

Referenzierung 3-D-Schablone Verifizierung 3-D-Schablone 39 Bohrung 3-D-Schablone(50 mm) Bohrung 3-D-Schablone (100 mm) ... 40

Bohrung an der 3-D-Schablone über eine Länge von 150 mm (links) und 50 mm (rechts). ... 41

Präparation eines Spongiosaquaders mit 10 Titanstiften der „entry“-Ebene ... 43

Versuchsaufbau für die Bohrungen am Spongiosaquader ... 44

Fixierung des Pointers Ausmessung der Verifizierung ... 45

Detailaufnahme: Messung zwischen Titanstift und Pointerspitze... 45

Bohrung am Spongiosaquader (Abdecktuch wurde entfernt)... 47

Bohrung am Spongiosaquader zum Zeitpunkt der Vollendung der Trajectory... 47

Bohrung (S2) Spongiosaquader Bohrung (S3) Spongiosaquader 47 Planung von S2 ... 48

Messung der Abweichungen des „exits“ ... 48

Versuchsaufbau Kunststoff-OSG ... 50

Paar-Punkt-Registrierung mit dem geraden Pointer an der anterioren distalen Tibia .... 51

Verifizierung an Fiducials an der subtalaren Gelenkfläche (Modell ohne Calcaneus) .. 52

Registrierung mit dem geraden Pointer am Kadaver-OSG ... 54

Landmarks (PPR) am OSG Landmarks (PPR) mit 12 Punkten der Oberflächenregistrierung... 54

Navigierte Bohrung von S1 ... 56

Setzen der 4 Schrauben zur OSG-Arthrodese nach Zwipp... 58

Unterteilung rechter Talus ... 79

7.5 Abkürzungen

CAS Computer assisted surgery

CT Computertomographie

DRB Dynamische Referenzbasis

FOV Field of view

LED Light Emitting Diode OR Oberflächen-Registrierung PPR Paar-Punkt-Registrierung ROI Region of interest

SI-Gelenk Sacro-Iliacal-Gelenk

7.6 Danksagungen

An dieser Stelle möchte ich mich bei allen Personen bedanken, die zum Gelingen dieser Arbeit in wissenschaftlicher oder technischer Hinsicht beigetragen haben.

Prof. Dr. C. Krettek: Ihnen möchte ich für die bereitwillige Übernahme meiner Arbeit und die Unterstützung unserer Arbeitsgruppe in der Erforschung dieser fortschrittlichen Technologien danken.

Prof. Dr. T. Pohlemann: Ihnen möchte ich für die Idee zu dieser Arbeit danken. Sie haben mir im OP die Problematik anhand der Pedikelschrauben vorgeführt.

Prof. Dr. T. Hüfner: Dir danke ich herzlich für die umfassende vorbildliche Betreuung Während dieser Arbeit und dass Du mich hineinschnuppern lassen hast in die Welt, in der Medizin und Technik

verschmelzen.

Dr. M. Citak: Dir danke ich für die intensive Einarbeitung und für das

besonders freundschaftliche Arbeiten mit Dir im Labor und in der Betreuung der Operationen. Einen Kollegen wie Dich wünscht man sich im Alltag.

Dr. J. Geerling, Dr. M. Oszwald, Dr. Dinah Kempe: Euch vielen Dank für die gute Zusammenarbeit in der Arbeitsgruppe.

Dr. M. Kfuri, Dr. M. Olsen: Herzlichen Dank für Ihre fruchtbare Mitarbeit bei den Versuchen für diese Arbeit.

Forschungswerkstatt: Danke für die technischen Ratschläge und Anfertigungen von Geräten für die Versuche an Herrn Rostkowski, Herrn Hansmann

Fotolabor UCH: Danke für die ständige Bereitschaft zur professionell

Durchgeführten Fotodokumentation, die dieser Arbeit zugrunde liegt.

CT-Mannschaft: Danke für die vielen CT-Scans der unzähligen Spongiosaquader und der Füsse.

Herr Geerlings: Vielen Dank für Ihre Unterstützung bei der statistischen Auswertung.

7.7 C U R R I C U L U M V I T A E

Persönliche Daten Gunther Oldag

geb. am 20.01.1968 in D-29525 Uelzen verheiratet, 1 Kind

Ausbildung und Zivildienst

Mai 1987 Abitur

08/1987 – 01/1991 Berufsausbildung zum Orthopädieschuhmacher bei Fa.

Schievink, Hannover

11/1991 – 01/1993 Zivildienst als Rettungshelfer beim Deutschen Roten Kreuz, Hameln

10/1993 – 09/1996 Berufsausbildung zum Masseur und medizinischen Bademeister an der Weserberglandklinik Höxter und bei Prof. Dr. Gehrke in der Klinik für Physikalische Medizin und Rehabilitation der MH Hannover

10/1996 – 10/2004 Studium der Humanmedizin an der MH Hannover 06. Dezember 2004 Approbation

Berufstätigkeit

02/1991 – 09/1993 als Orthopädieschuhmacher Basischirurgie

04/2005 – 01/2006 Abteilung für Chirurgie im Martins-Krankenhaus Lilienthal unter Leitung von Dr. D. Stemme

02/2006 – 03/2007 Abteilung für Traumatologie und Orthopädische Chirurgie in der Ubbo-Emmius-Klinik Aurich unter Leitung von Dr.

G. Müller

seit 04/2007 Spezielle Unfallchirurgie und Orthopädie

Abteilung für Traumatologie und Orthopädische Chirurgie in der Ubbo-Emmius-Klinik Aurich unter Leitung von Dr.

G. Müller Doktorarbeit

seit 11/1999 an der Klinik für Unfallchirurgie der MH Hannover ( Leitung: Prof. Dr. Krettek ) zum Thema

„Präzisionsbestimmung von CAS-navigierten Bohrungen am Beispiel der OSG-Arthrodese“

13.09.2001: Vortrag „Präzisionsanalyse von CAS-navigierten Bohrungen“ auf der 20. Steglitzer

Unfalltagung in Berlin, Leitung Prof. Dr. Rahmanzadeh Hospitationen

12. – 24.04.2004 Klinik für Handchirurgie der Herz- und Gefäß-Klinik GmbH der Rhön-Klinikum AG, Bad Neustadt unter der Leitung von Prof. Dr. U. Lanz