Upper Limb Movement Encoding by Intracortical Recordings in Human Sensorimotor Cortex

N/A
N/A
Protected

Academic year: 2022

Aktie "Upper Limb Movement Encoding by Intracortical Recordings in Human Sensorimotor Cortex"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Upper Limb Movement Encoding by Intracortical Recordings in Human Sensorimotor Cortex

D. Royston2,4*, S.T. Foldes1,4, J. Downey2,4, J. Weiss1,2, E. Tyler-Kabara1,2,3,5, M. Boninger1,2,5,6, R.

Gaunt1,2,4, J.L. Collinger1,2,4,6

1Dept. of Physical Medicine and Rehabilitation; 2Dept. of Bioengineering; 3Dept. of Neurological Surgery; 4Center for the Neural Basis of Cognition; 5McGowan Institute for Regenerative Medicine, University of Pittsburgh,

Pittsburgh, PA, USA; 6Dept. of Veterans Affairs Medical Center, Pittsburgh, PA, USA;

*3520 Fifth Ave, Suite 300, Pittsburgh, PA 15213, USA. E-mail: dar147@pitt.edu

Introduction: In recent years, neuroprosthetics driven by brain-computer interfaces (BCI) have emerged as a potential tool for restoring independence to people paralyzed by disease and injury. Extracting command signals from intracortical recordings in primary motor cortex (M1) allows complex motor commands to be decoded. Here we investigate the distribution of movement-related information in recordings from the motor and somatosensory cortex of a person with chronic tetraplegia.

Materials, Methods, and Results: Two 88-channel arrays were implanted in M1 and two 32-channel arrays were implanted in the somatosensory cortex (S1) of a 27-year old individual with chronic tetraplegia due to C5/C6 SCI (Fig 1A). Implant locations were targeted to arm and hand regions of M1/S1 based on pre-surgical functional neuroimaging. Intracortical recordings were collected once monthly for 7 months while the subject attempted to move in time with videos of arm and hand movements, although most movements could not be performed overtly. Unit tuning was defined by the R2 coefficient of the linear fit between single-unit firing rates and a 0.5Hz sine wave matching the pacing of stimulus videos (significance p<0.05, Bonferroni corrected).

We found robust single-unit tuning to all attempted movements across the entire 7-moth testing period (see Table 1).

Single-unit firing rates were tightly correlated with the time-course of attempted movements, including those of fingers paralyzed by the SCI (Fig 1B). Units tuned to finger- and wrist-related movements were fairly evenly distributed between motor arrays, while those tuned to elbow and shoulder movements were highly biased towards the medial array. While there were overall fewer significantly tuned units on the S1 arrays, we identified single sensory neurons tuned to both overt and attempted movements, and both sensory arrays had more units tuned to attempted than overt movements.

(Left) Table 1: Number of units significantly tuned to each movement, averaged across days. (A) = attempted movement, (O) = overt movement.

(Right) Figure 1 - A: Placement of microelectrode arrays in M1/S1, plotted on cortical surface render. Blue = motor, red = sensory. B: Single-unit activity on the lateral motor array during attempted pinky movement. Purple line represents smoothed across-trial spike count.

Discussion: These results demonstrate the preservation of volitional single-unit sensorimotor activity during both intact and paralyzed movements. The spatial distribution of tuned units shows that while a degree of somatotopy exists, units separated by centimeters of cortex can be similarly tuned to the same movement, suggesting that even simple movements can be encoded by large areas of cortex.

Significance: BCI control is predicated on the ability to decode motor commands from single-unit activity.

Understanding how those commands are represented in the sensorimotor cortex of BCI users is an important step towards developing more effective neuroprosthetic control.

Acknowledgments: This material is based upon work supported by DARPA contract number: N66001-10-C-4056.

Movement

Motor Medial [#units]

Motor Lateral [#units]

Sensory Medial [#units]

Sensory Lateral [#units]

(A)Pinky 11.71 10.00 6.28 4.00

(A)Ring 31.00 25.00 8.50 7.33

(A)Middle 26.33 27.00 10.33 7.83

(A)Index 22.43 20.29 9.43 4.00

(O)Thumb 32.80 35.80 13.4 11.60

(A)Grasp 16.86 14.14 5.43 4.14

(O)Wrist 16.38 18.13 5.00 3.87

(O)Elbow 17.33 12.00 4.33 3.83

(O)Shoulder 35.00 10.33 3.67 2.00

DOI: 10.3217/978-3-85125-467-9-88 Proceedings of the 6th International Brain-Computer Interface Meeting, organized by the BCI Society

Published by Verlag der TU Graz, Graz University of Technology, sponsored by g.tec medical engineering GmbH 88

Referenzen

ÄHNLICHE DOKUMENTE

The present study evaluated features about individual finger movements of one hand, which were previously studied using ECoG [Miller et al., 2009], in noninvasive EEG,

The EC radiation observed on the high field side is dominated by relativistically downshifted emission by the high energy end of the electron distribution function and can thus

Note that co-occurrence of discrete and rhythmic move- ments is supported by a study on whisker movements in rats by Haiss and Schwarz (2005), where it was found that rhyth- mic

Using Lesson Study to Help Teachers Design Lessons with Purposeful Planned Movement and Build Efficacy.. by

sheep (n = 11 in the predictable rich housing group; n = 7 in the unpredictable poor housing 914. group) approached the corresponding boxes at the relative distances from

To this end, we adopted a combination of MVPA and connec- tivity analysis to investigate: (1) which regions host action and goal information during the planning and execution of

In the present study, using a cross-decoding MVPA based on machine learning, we report that task-similar brain activity related to wrist and finger movements exists in the resting

Graphical correlation of the calculated σ - ρ C at dif- ferent carbon atoms with the corresponding C-H vibration frequencies ν for each car- bon atom in benz[a]anthracene radical