• Keine Ergebnisse gefunden

New Method for Determination of Electrically Inactive Phosphorus in n-type Emitters

N/A
N/A
Protected

Academic year: 2022

Aktie "New Method for Determination of Electrically Inactive Phosphorus in n-type Emitters"

Copied!
5
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

1876-6102 © 2015 Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

Peer review by the scientific conference committee of SiliconPV 2015 under responsibility of PSE AG doi: 10.1016/j.egypro.2015.07.045

Energy Procedia 77 ( 2015 ) 316 – 320

ScienceDirect

5th International Conference on Silicon Photovoltaics, SiliconPV 2015

New method for determination of electrically inactive phosphorus in n-type emitters

Michael Steyer*, Amir Dastgheib-Shirazi, Giso Hahn, Barbara Terheiden

Department of Physics, University of Konstanz, 78457 Konstanz, Germany

Abstract

The precise knowledge of the amount and the location in depth of inactive phosphorus in an n-type emitter is still a challenge. As a new approach, we determine the total amount of phosphorus (P dose) in the emitter stepwise in dependence of etching depth with the characterization tool ICP-OES. A comparison of the data with the electrically active P concentration profile measured by ECV allows to determine in which depths electrically inactive phosphorus is present. For a highly doped emitter, we show that most of the inactive P dose is located next to the sample surface. Furthermore, we compare the determined P dose in dependence of depth with the P dose extracted from a SIMS profile. In a second experiment, we investigate the amount of inactive phosphorus in the whole emitter for various n-type emitters, depending on the POCl3-N2 gas flow as a significant diffusion parameter. It is shown that an increase of the POCl3-N2 gas flow results in a saturation effect of the active phosphorus, while the amount of inactive phosphorus is strongly increasing.

© 2015 The Authors. Published by Elsevier Ltd.

Peer review by the scientific conference committee of SiliconPV 2015 under responsibility of PSE AG.

Keywords: electrically inactive phosphorus; dead layer; P dose; n-type emitter; ICP-OES; ECV; SIMS

1. Introduction

A homogenous n-type emitter is most commonly formed by POCl3 diffusion. During the diffusion process PhosphoSilicate Glass (PSG) grows on the silicon wafer and acts as dopant source. Because of the solubility limit of phosphorus in crystalline silicon, highly doped emitters have normally a so-called dead layer next to the surface.

* Corresponding author. Tel.: +49-7531-882081; fax: +49-7531-883895.

E-mail address: michael.steyer@uni-konstanz.de

Available online at www.sciencedirect.com

© 2015 Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

Peer review by the scientific conference committee of SiliconPV 2015 under responsibility of PSE AG

Konstanzer Online-Publikations-System (KOPS) URL: http://nbn-resolving.de/urn:nbn:de:bsz:352-0-304212

(2)

This electrically inactive phosphorus acts as recombination center and increases emitter saturation current density [1]. The amount and the location of the inactive phosphorus is of great interest to understand phosphorus precipitate formation. Standard analytical methods currently applied are Secondary Ion Mass Spectrometry (SIMS) for the total phosphorus concentration profile or an Electrochemical Capacitance-Voltage profiler (ECV) [2] for an electrically active P concentration profile. However, the comparison of ECV and SIMS profiles and therefore the detection of the location in depth of inactive phosphorus is often difficult [3]. In this study, we used the wet- chemical emitter etch-back procedure to remove the emitter stepwise [4] and analyze the etch solution with Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) [5] to determine the total amount of phosphorus per unit area (P dose) in the emitter. With this analytical method sputtering effects are avoided, which are part of SIMS measurements. On the other hand, the electrically active P dose of the emitter was measured by ECV. The knowledge of the total and the active P dose finally allows the determination of the inactive P dose.

2. Method and experimental details

2.1. Determination of the P dose in the whole emitter

The base material is p-type, 5x5 cm2 Czochralski silicon wafers with a bulk resistivity of 2 ȍcm. The wafers are wet chemically cleaned before the POCl3 diffusion process. Different types of the emitters have been created by changing the POCl3-N2 gas flow ĭPOCl3 as a significant diffusion parameter. Afterwards, the PSG is removed in lowly concentrated hydrofluoric acid. Finally, the whole emitter is removed (2 μm per wafer side) in an etching solution of hydrofluoric and nitric acid. This etching solution of a defined volume is investigated by ICP-OES to determine the total amount of phosphorus Qtotal within the whole emitter (mP: mass of phosphorus in the total etching solution, A: surface area of the etched wafer (both sides), NA: Avogadro constant, MP: molar mass):

P A

total

P

Q m N

A M (1)

On the other hand, the same unetched emitters have been measured by ECV to determine an active doping profile.

The integration of the ECV profile yields the active P dose Qactive of the whole emitter (C: phosphorus concentration, x: depth, compare Fig. 1):

active 0

Q C(x)dx

f

³

(2)

The difference in the emitter P dose determined by ICP-OES (Qtotal) and ECV (Qactive) indicates the electrically inactive phosphorus dose (Qinactive). Furthermore, we compare the Qtotal determined by ICP-OES with the Qtotal

extracted from SIMS profiles [6] of the same emitters using equation (2), (see Fig. 2, left).

2.2. Determination of the P dose stepwise for one emitter-type

The samples are prepared, as described in the first part, using just one emitter type (ĭPOCl3=const.). In contrast to the first investigation, the emitter is only partly removed. The challenge was to find the right etching solution, with low etching rate, high homogeneity and suitable background signal for the ICP-OES measurement (see e.g. the problem with carbonate [7] based acid). As the etched area is necessary to be known for the calculation of Qtotal (see equation (1)), it is also important that no porous silicon is formed durig etching. We successfully found an etching solution with an etching rate of 0.5 nm/s. For the stepwise analysis of the P dose, several samples with the same emitter profile have been etched down to different depths. Each etching solution is analyzed by ICP-OES. To determine the total P dose of the remaining emitter profile ǻQtotal, unetched, the P dose Qtotal, etched is subtracted from the total P dose of the whole emitter depth Qtotal (compare Fig. 1). The active P dose Qactive, unetched of the remaining emitter profile is determined by ECV. The etching depth is determined by comparing the depths values at a defined

(3)

P concentration of 1020 cm-3 (or maximum if less) of each profile with the original profile (42 Ÿ/Ƒ), see Fig. 3 (right). For comparison, we also determine the Qtotal, unetched of the SIMS profile, using the etching depth as lower integration limit for equation (2) (see Fig. 4). The sheet resistance (RSheet) of the remaining emitters is measured by a Four-Point-Prober (4PP).

Fig. 1. Typical n-type emitter profile for the total (SIMS measurement) and the electrically active phosphor concentration (ECV measurement).

The area under the ECV curve indicates the active P Dose, while the area under the SIMS curve indicates the total P dose. The removed emitter part is analyzed with ICP-OES to determine Qtotal, etched and should be identical with the removed area of the SIMS profile. The left graph shows the usual logarithmic scaling for the concentration, while the right graph shows the linear scaling.

3. Results and discussion

3.1. Determination of the P dose in the whole emitter

The P dose in the whole depth of the emitter in dependence of the POCl3-N2 gas flow diffusion parameter is shown in Fig. 2 (left). The total P dose is measured by ICP-OES, while the electrically active P dose is determined by the ECV profiles (see Fig. 2, right) of the unetched wafers. The total P doses of emitters created with POCl3-N2

gas flows of 250 sccm, 375 sccm, 500 sccm and 750 sccm are additionally determined by SIMS profiles. The Qtotal

determined by ICP-OES is in good agreement with the Qtotal extracted from SIMS profiles.

Fig. 2. P dose in the whole emitter in dependence of the POCl3-N2 gas flow (left graph). To make sure the whole emitter is etched, at least 2 μm per side have been removed from the silicon wafer. The total P dose is measured by ICP-OES, while the electrically active P dose is determined by the ECV profile (right graph) of the unetched wafer. In addition, the total P dose is also extracted from SIMS profiles.

50 100 150 200 250 300 1016

1017 1018 1019 1020

1021 Qactive, unetched (ECV)

Qtotal, etched (ICP-OES)

Qtotal, unetched (SIMS)

P concentration [cm-3 ]

Depth [nm] 50 100 150 200 250 300

2 4 6 8 10 12 14 16 18 20

Qactive, unetched (ECV)

Qtotal, etched (ICP-OES)

Qtotal, unetched (SIMS)

P concentration [1020 cm-3 ]

Depth [nm]

250 500 750 1000 1250 1500 0

2 4 6 8

10 Qactive (ECV)

Qtotal (ICP-OES) Qtotal (SIMS)

P dose [1015 cm-2 ]

POCl3-N2 gas flow [sccm]

0 50 100 150 200 250 300

1017 1018 1019 1020

125 sccm 250 sccm 375 sccm 500 sccm 625 sccm 1000 sccm

P concentration [cm-3 ]

Depth [nm]

(4)

For low POCl3-N2 gas flows of 125 sccm and 250 sccm the P dose determined by ECV and ICP-OES is similar, which means that there is low density of inactive phosphorus. For a higher gas flow, the difference between the P dose determined by ECV and ICP-OES increases, which means that the amount of electrically inactive phosphorus is increasing. At ĭPOCl3=625 sccm only half of the total phosphorus is electrically active. Qactive saturates at a value of 2.3·1015 cm-2.

3.2. Determination of the P dose stepwise for one emitter type

The total and the active P dose of a stepwise etched-back emitter (unetched 42 Ÿ/Ƒ, see Fig. 2: ĭPOCl3=750 sccm) in dependence of the etching depth is shown in Fig. 3 (left). After each etching step, RSheet and the ECV profile (see Fig. 3 right) were measured. Most of the inactive phosphorus is located next to the surface. With increasing etching depth, the total amount of phosphorus atoms approaches the number of active phosphorous atoms. The slope of the P dose function gives the P concentration. In Fig. 4, the total P dose extracted from the SIMS profile is also shown.

SIMS and ICP-OES measurement show the same trend for the total P dose.

Fig. 3. P dose of a stepwise etched emitter (42 Ÿ/Ƒ). To determine the total P dose of the remaining emitter, the measured P dose is subtracted from the total P dose of the whole emitter. The remaining emitters are measured by ECV to determine the active P dose. The ECV profiles (right graph) are indicated by the corresponding RSheet in the left graph. The etching depth is determined by the ECV profiles. Therefore, the plateau at a defined P concentration of 1020 cm-3 (or maximum if less) is extracted for each profile and subtracted from the depth of the original profile (42 Ÿ/Ƒ).

Fig. 4. P dose of a stepwise etched emitter, as in Fig. 3 left. Additionally, we determined the total P dose of the SIMS profile, using the etching depth as lower integration limit for equation (2).

0 20 40 60 80 100 120 140 0

1 2 3 4 5

6 Qactive, unetched (ECV)

'Qtotal, unetched (ICP-OES)

148 109 68

56 RSheet [:…]

46

P dose [1015 cm-2 ]

Depth [nm]

0 50 100 150 200 250 300

1017 1018 1019 1020

42 :… 46 :… 56 :… 68 :… 109 :… 148 :…

P concentration [cm-3 ]

Depth [nm]

0 20 40 60 80 100 120 140 0

1 2 3 4 5

6 Qactive, unetched (ECV)

'Qtotal, unetched (ICP-OES) Qtotal, unetched (SIMS)

P dose [1015 cm-2 ]

Depth [nm]

(5)

Further experiments can be improved by determining the etching depth not by ECV, but by the etching rate (0.5 nm/s). In this case, only one ECV profile of the reference emitter is needed. The active P dose depending on the depth can be calculated by using the etching depth as lower integration limit for equation (2) (as already demonstrated for the SIMS measurement). Furthermore, only one sample is needed for the ICP-OES measurement:

After each etching step, the etching solution is decanted and the sample is used for the next etching step.

4. Conclusion

In the first experiment, we investigated the amount of electrically inactive phosphorus in the emitter systematically in dependence of the POCl3-N2 gas flow. We showed that the electrically active P dose saturates for high POCl3-N2 gas flows, while the total P dose is continuously increasing. This successfully demonstrated method can help to optimize POCl3 diffusion parameters by keeping the active P dose constant and minimize the inactive P dose, e.g. by performing a design of experiment.

In the second experiment, we successfully determined the inactive P dose depending on the emitter depth. We showed that most of the inactive phosphorus is located next to the surface. This is already considered in solar cell production to improve the electrical performance of a crystalline silicon solar cell [4]. Our new method allows to quantify the removed inactive phosphorus and to optimize the etching depth for different emitter types.

Acknowledgements

The authors would like to thank Johannes Rinder for support during processing. Part of this work was financially supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (FKZ 0325581). The content of this publication is the responsibility of the authors.

References

[1] Choulat P, Duerinckx F, Van Kerschaver E, Dross F, Beaucarne G. Minimizing the dead layer of industrial phosphorous emitters formed by POCl3 diffusion. Proc. 15th PVSEC, Shanghai, 2005.

[2] Blood P. Capacitance-voltage profiling and the characterisation of III-V semiconductors using electrolyte barriers. Semicond Sci Technol 1986:1:7-27.

[3] Bock R, Altermatt PP, Schmidt J. Accurate extraction of doping profiles from electrochemical capacitance voltage measurements. Proc. 23rd EUPVSEC, Valencia, 2008.

[4] Dastgheib-Shirazi A, Haverkamp H, Raabe B, Book F, Hahn G. Selective emitter for industrial solar cell production: a wet chemical approach using a single side diffusion process. Proc. 23rd EUPVSEC, Valencia, 2008.

[5] Hou X, Jones BT. Inductively Coupled Plasma-Optical Emission Spectrometry. Encyclopedia of Anal Chem 2008:9468-9485.

[6] Dastgheib-Shirazi A, Steyer M, Micard G, Wagner H, Altermatt PP, Hahn G. Relationships between diffusion parameters and phosphorus precipitation during the POCl3 diffusion process. Energy Procedia 2013;38:254-62.

[7] Rocha M, Mesko M, Silva F, Sena R, Quaresma M, Araújo T, Reis L. Determination of Cu and Fe in fuel ethanol by ICP OES using direct sample introduction by an ultrasonic nebulizer and membrane desolvator. J Anal At Spectrom 2011:26:456-461.

Referenzen

ÄHNLICHE DOKUMENTE

Nevertheless, concentrations and phytotoxin patterns strongly varied Fig. a) Absolut method recoveries of target phytotoxins at 10 ng/L with the green line indicating the ideal and

We simulated crop production and the related C and N fluxes of conventional and organic cropping systems in the long-term experiments of DOK (Switzerland) and Foulum (Denmark) with

Activation agent: Activated Biochar (AB) produced from mixed wood sieved to 2–4 mm using different gas mixtures at different molar ratios of activation agent to feedstock carbon..

Abbreviations: BIODYN, organic cropping system of the DOK trial; COM, compost treatment of the ZOFE trial; CONFYM, conventional cropping system (organic and mineral fertilizers) of

3.Exceedance of the critical load of acidity at the 17 ICP IM sites: (a) Acidity CLF for the sites and their normalized depositions in 2017 (Note: for two sites the N deposition is

The observed concentration dependent increase of plasma VTG in male zebra fi sh after 21 days of exposure (signi fi cant 4.4 and 8.1 fold induction in 1000 and 3200 ng/L,

Model building was done using a spatial cross-validation using spatial blocks for fold crea- tion which is believed to have minimized dependence of training and test data.. The

However, both species showed rapid recovery or even growth compensation after summer droughts but displayed slow recovery in response to spring droughts where none of the two