Simple, robust eddy correlation amplifier for aquatic dissolved oxygen and hydrogen sulfide flux measurements

Daniel F. McGinnis

1,2*

, Sergiy Cherednichenko

1

, Stefan Sommer

1

, Peter Berg

3

, Lorenzo Rovelli

1

, Ralf Schwarz

1

, Ronnie N. Glud

2,4,5

, and Peter Linke

1

1IFM-GEOMAR, Leibniz Institute of Marine Sciences, RD2 Marine Biogeochemistry, Kiel, Germany D-24148

2Southern Danish University, Institute of Biology and Nordic Center for Earth Evolution (NordCee), 5230 Odense M, Denmark

3Department of Environmental Sciences, University of Virginia, Charlottesville, VA 22904-4123

4Greenland Climate Research Centre (Co. Greenland Institute of Natural Resources), Kivioq 2, Box 570, 3900 Nuuk, Greenland

5Scottish Association for Marine Science, Dunstaffnage Marine Laboratory, PA37 1QA, Dunbeg, Scotland

Limnol. Oceanogr.: Methods9, 2011

© 2011, by the American Society of Limnology and Oceanography, Inc.

Web Appendix A

Referenzen

ÄHNLICHE DOKUMENTE

The purpose of the present study was to compare different halitosis detection methods (organoleptic assessment, Hali- meter, Fresh Kiss, Halitox).. The Halimeter was used as a

Since the image modalities are different, a direct comparison of gray values is not advisable and we hence study a mutual information based approach. Figure 1c) displays

Performance met- rics show that for all stability classes (convective, neutral, and stable scenarios), the footprint parameterisation is able to predict the footprints simulated by

Bacterial sulfate reduction (BSR) presumably involved a re- oxidation of sulfide by organic matter as proposed earlier, but also a sulfurization of OM yielding reduced organic

By combining the hyperbolic relaxed eddy accumulation method (HREA), whole-air sampling and high precision isotope ratio mass spectrometry (IRMS), 13 CO 2 and CO 18 O isotopic

In order to match the physical tube delay to valve switching and to receive the correct setting for the software delay (delay_for valve_switching), decrease the number of the

The data quality assessment is separated into three parts: analysis of the wind statistics, as- signment of quality flags for the flux measurements, and footprint evaluation.. While

Figure 2: Eight-day period with data of (a) measured CO 2 fluxes for the neighboring INT and EXT fields, (b) wind direction, (c) footprint contribution of INT and EXT field to the