• Keine Ergebnisse gefunden

Supplementary materials

N/A
N/A
Protected

Academic year: 2022

Aktie "Supplementary materials"

Copied!
6
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Supplementary materials

Supplementary material section 1:

Images were subjected to an automated threshold algorithm to eliminate the

autofluorescence of the skin. The algorithm was programmed in ImageJ software and

contained two macros that were run subsequently and likewise for each image. The program code of the macros applied is provided below:

Macro 1:

// Color Thresholder 1.52a

// Autogenerated macro, single images only!

min=newArray(3);

max=newArray(3);

filter=newArray(3);

a=getTitle();

run("RGB Stack");

run("Convert Stack to Images");

selectWindow("Red");

rename("0");

selectWindow("Green");

rename("1");

selectWindow("Blue");

rename("2");

min[0]=0;

max[0]=0;

filter[0]="stop";

min[1]=33;

max[1]=255;

filter[1]="pass";

min[2]=0;

max[2]=0;

filter[2]="stop";

for (i=0;i<3;i++){

selectWindow(""+i);

setThreshold(min[i], max[i]);

run("Convert to Mask");

if (filter[i]=="stop") run("Invert");

}

imageCalculator("AND create", "0","1");

imageCalculator("AND create", "Result of 0","2");

for (i=0;i<3;i++){

selectWindow(""+i);

close();

}

selectWindow("Result of 0");

(2)

rename(a);

// Colour Thresholding--- Macro 2:

run("Invert");

(3)

Supplementary material section 2:

The physical stability of the formulations (macroemulsion (ME), nanoemulsion (NE) and nanostructured lipid carriers (NLC)) was assessed by using laser diffraction (LD), photon correlation spectroscopy (PCS) and light microscopy over a period of 5 weeks.

Storage conditions: room temperature and exclusion of light.

0 20 40 60 80 100 120 140 160 180

laser diffraction (LD)

d(v)0.5 d(v)0.9 d(v)0.95 d(v)0.99

particle size [µm]

0 200 400 600 800 1000

-0.1 0.0 0.1 0.2 0.3 0.4 0.5 0.6

photon correlation spectroscopy (PCS )

z-average [nm] PdI

particle size [nm] PdI

Fig. S2-1: Particle size analysis (LD and PCS) over 5 weeks. Mean values ± S.D.. Data showed an instability of the particles contained in the ME. In case of NE, the LD technique detected larger drops after 7 days. The particle sizes of the NLC remained unchanged - meaning a more effective stabilization of the of the lipid nanoparticles in comparison to the emulsion droplets.

(4)
(5)

Supplementary material section 3:

Selected images of epifluorescence microscopic images (magnification: 200-fold) of skin biopsies – non-treated and treated with Dil loaded in oil, NE, NLC and ME after 1h (Fig. S3-1) and 6 h (Fig. S3-2) peneteation time.

untreated skin

oil

NE

NLC

ME

Fig. S3-1: Images of skin biopsies after 1 h penetration time.

(6)

oil

NE

NLC

ME

Fig. S3-2: Images of skin biopsies after 6 h penetration time.

Referenzen

ÄHNLICHE DOKUMENTE

From the point of view of the history of science, Gessner’s model has advantages in comparison with Fleming’s, namely the more clear introduction of historical dimension

In this study, self-microemulsifying drug delivery systems were tested using the in vitro dispersion test (without digestive enzymes) and, based on these data, an in vitro–in

3 COMPARISON OF DIFFERENT IN VITRO TESTS TO ASSESS ORAL LIPID-BASED FORMULATIONS USING A POORLY SOLUBLE ACIDIC DRUG

According to the comparative results of application between imatinib solution and imatinib encapsulated tetraether lipid liposomes, tetraether lipid liposomes were

The RRM KalypsoNA and KalypsoHydrology with the functionality to simulate the hydrologic 

Measurements of the density of phonon states with inelastic neutron scattering, of the heat capacity and of the elastic constants with resonant ultrasound spectroscopy offer a

No oral corticosteroid therapy for RA Research team's screening to identify patients who potentially would be eligible for the NLC FU.. Patient eligible for the NLC FU and next

In addition to analyzing analytical method-specific data for each of the separate BI1361849-encoded antigens, broader statistical categories were used to assess post-baseline