• Keine Ergebnisse gefunden

Coupling MELCOR to other Codes

N/A
N/A
Protected

Academic year: 2022

Aktie "Coupling MELCOR to other Codes"

Copied!
12
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Institute for Nuclear and Energy Technologies (IKET) Karlsruhe Institute of Technology (KIT)

Coupling MELCOR to other Codes

Tobias Szabó

4

th

Meeting of the “European MELCOR User Group (EMUG)”

April 16-17 2012, Köln, Germany

http://www.comintec.it

backslash free jaw coupling "GAS/SG”

(2)

Outline

1. Introduction

2. MELCOR coupling interface 3. Test case

4. Conclusion and perspective

(3)

1. Introduction

Coupling of simulation codes = exchange boundary condition + coordination of time advancement

Coupling to add modelling capacities to a code

Coupling of MELCOR and the 3D CFD code GASFLOW

(containment thermal hydraulics, hydrogen distribution and burn) MELCOR can be coupled to other codes through

existing coupling interface

(4)

2. MELCOR coupling interface

MELCOR coupled to RELAP5-3D (Parallel Virtual Machine, PVM) MELCOR coupled to GILA (Message Passing Interface, MPI)

Code coupling system

Executive program PVMEXEC (INL) or MPIEXEC (SANDIA)

Similar coupling interface in each code

(5)

2. MELCOR coupling interface

MELCOR coupling routines in versions 1.8.5 and 1.8.6:

mexpvi, mexpvs, mexpvt, mexpvx, mexsnd, mexrcv

Coupling routines for MPI are not functional in version 1.8.6 Identified problems

Missing variable definitions

call mpi_reduce( value8(iv1),temp8(iv1),nvar, 1 mpi_double_precision,mpi_sum,0,

2 mpi_comm_reduce(myprocnum,i),info )

Modifications

(6)

2. MELCOR coupling interface

Requirements for MPI coupling

Executive program for coupling MPIEXEC (SANDIA) Modifications in the MELCOR 1.8.6 coupling routines Implementation of MPI 2 standard, e.g. MPICH 2

Coupling interface must be implemented into second code

(7)

3. Test case

Coupling two instances of MELCOR

BWR after shutdown Decay heat

Outflow through safety relief valve

Hydrogen production Hydrogen burn

containment

wetwell CV200

v e s s e l

burn SRV

simplified exercise from MELCOR

workshop 2001

(8)

Containment

containment

wetwell CV200 CVH-P.200

burn

3. Test case

Vessel

v e s s e l

SRV

FL-VELVAP.199 CFVALU.7

CV CFVALU.2

Cole (2002) CV200

CFVALU.1

(9)

3. Test case

single containment vessel

CFVALU.1

(10)

4. Conclusion and perspective

Conclusion

MELCOR 1.8.6 MPI coupling interface is fuctional after modifications Control Function utility is used for defining boundary conditions

Example of two coupled MELCOR instances

Perspective

At KIT coupling MELCOR to GASFLOW

MELCOR 2.1 coupled to other codes in the future

(11)

Thank you for your attention!

Contact:

Tobias Szabó

Phone: +49 721 608-28320

Email: tobias.szabo@kit.edu

(12)

Appendix literature

Literature:

R.K. Cole. Coupling of MELCOR to Other Codes under an Executive

Program using PVM Message Exchange. SAND2002-2440C. Sandia

National Laboratories, Albuquerque, NM, USA. 2002.

Referenzen

ÄHNLICHE DOKUMENTE

a Fukui Institute for Fundamental Chemistry, Kyoto University, 34–4, Takano Nishihiraki-cho, Sakyo- ku, Kyoto 606–8103, Japan.. Reprint requests

This sign inversion, observed here for the first time for apparently similar compounds, demonstrates the enormous influence of substituents on the nature of the lone pair of

* We monitor our high stability reference quartz by comparison with the normal frequency of D C F 77 Main- flingen. Reprint requests

Example: Phase-Change Effective Convectivity Model (PECM) The coupling interface for MELCOR based on the MPI-Standard is available at the IKET (Dr. Tobias Szabó).. DINAMO

Stand-alone GASFLOW agree Coupling functions correctly MELCOR Containment (stand- alone) differs considerably as regards to GASFLOW pressure Rather trust in GASFLOW. pressure (very

The German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) financially supports analyses of severe accident sequences during shutdown modes

 The default value of the bubble rise velocity (0.3 m/s) in CVs results in a general underestimation of the CV void fraction.  A sensitivity calculation was performed with a

To calculate the inertial deposition of aerosols in pipe bends, the centrifugal force acting on the particle as the fluid turns a pipe bend is used to calculate a terminal