• Keine Ergebnisse gefunden

Comparison of outcomes for different users using the same exposure modelling tool; Stoffenmanager 2.0, when used in four different branches of industries

N/A
N/A
Protected

Academic year: 2022

Aktie "Comparison of outcomes for different users using the same exposure modelling tool; Stoffenmanager 2.0, when used in four different branches of industries"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

The ETEAM Conference - Challenges and Perspectives of Tier 1 Exposure Assessment, 25./26.03.2014 in Dortmund

Comparison of outcomes for different users using the same exposure

modelling tool; Stoffenmanager 2.0, when used in four different branches of industries

Hanna Landberg, Håkan Tinnerberg

Department of Occupational and Environmental Medicine, Institute of Laboratory Medicine, University Hospital, 221 85, Lund, Sweden

Abstract

Stoffenmanager was developed to be a control banding tool regarding inhalable exposure to chemicals helping small and medium-sized enterprises with their risk assessments. However, Stoffenmanager continued to develop and a quantitative exposure assessment part of the tool was soon available with the 90th percentile of the predicted exposure as outcome. The aims of this study was to examine if different users of the same exposure modelling tool (Stoffenmanager) come to the same result when modelling the same task and if workers are protected when only relying on the outcomes of the tool. The users were all simultaneous at the working sites, studying the scenarios. The study was done regarding inhalable exposure at four companies in different branches of industry; wood, printing shops, metal foundry and spray painting. Three scenarios at each company were modelled and measured, consensus assessments were also modelled for each scenario. The differences between the multiple users of the model were large in the quantitative exposure assessment part. Half of the scenarios, spread over the industries, had a wide range between the outcomes. The parameters in Stoffenmanager that had shown to differ more than others in answers were: if it concern shaping of material, characterization of task, frequency, breathing zone, personal protection, inspections and maintenance of machines and control measures. When comparing the measured exposures with the consensus 90th percentile outcome in the quantitative exposure assessment part of Stoffenmanager only two scenarios had a slightly higher measured exposure value than modelled.

Referenzen

ÄHNLICHE DOKUMENTE

4 Proximal plaque indices (with standard deviation) de- termined after one week brushing with either the Superbrush, the Elmex interX or the participant’s own toothbrush.. Shown

When casting high-alumina containing grades the mold slag composition can be significantly different from that of the original mold powder, even if the original mold powder

Because these investigations have focused on the shallow sediments just beneath the seafloor, where the diffusive mixing of hydrothermal fluids and seawater likely

To directly examine the magnitude of errors that can occur, we use dual whole-cell current- and voltage-clamp recordings from the soma of the pair of easily accessible,

This impact is characterized by the demand for indus- trial products necessary for building and operating the energy supply system, the required putting into

The objective of this study was to measure the rheological characteristics of different set yoghurts with a vane directly in the yoghurt cup “as it is” without partial destruction

Comprehensive external validation of the Tier 1 tools required the collection of a varied set of measurement data that reflect the range of substances and activities covered by

Choose most effective & reliable control options that minimise escape & spread of substances hazardous to health. • Each unit operation &