Introduction

Comprehensive external validation of the Tier 1 tools required the collection of a varied set of measurement data that reflect the range of substances and activities covered by the tools under REACh. This presentation summarises the data collection strategy, database structure and the methods used to generate tool estimates from the data for the external validation exercise.

Methods

Personal measurements of inhalation and dermal exposure were gathered from a variety of providers in the EU and US. Contextual information about the exposure situations was also obtained. Data collection focussed on process and substance types which were common to one or more Tier 1 tools- low volatility and volatile liquids, powders, metal abrasion processes, metal processing and wood processing.

Three types of exposure situations were collected: those with individual measurements of exposure; those where measurements of exposure had been aggregated within the situation and those where measurements had been aggregated across grouped situations.

The situations were coded into the tool parameters by a team of coders at the Institute of Occupational Medicine. To reduce between-user variability, coders received a detailed coding protocol and training. In addition to regular coding team meetings, results were checked for inconsistencies. The exposure situations and coded tool input parameters were entered into a database. Procedures were developed to run the tools and generate estimates.

Results

A wide range of relevant exposure situations (N=1,131) and associated measurement data was collected, covering a variety of substance types and industrial and downstream processes. A multi-functional database was developed to store the exposure situations.

Sufficient inhalation data were collected to allow a validation of the inhalation tools to proceed, however dermal data were limited in quantity and varied in sampling method. A dermal tool validation exercise could not therefore be carried out.

Tool estimates of exposure were generated using quality controlled methods for coding of input parameters and tool operation.

Conclusions

The final dataset allows validation of the inhalation tools across a suitable range of process and substance types. Sufficient dermal data for validation of the dermal tools were not collected. Numbers of inhalation data were limited in some categories, for example low volatility liquids, and the results of the validation should be considered in the light of the dataset limitations.

Referenzen

ÄHNLICHE DOKUMENTE

In order to evaluate tool uncertainty, possible sources of uncertainty such as input parameters or assumptions were for each tool and categorised according to transparency

Participant using ECETOC TRAv3 (75%) and STOFFENMANAGER (100%) reported high levels of uncertainty in assigning task or activity parameters when estimating exposure for situation

The Project team made an initial selection of potential data from a database collated by Provider G. These data had not been previously used in tool development, and were selected

A large part of the model (i.e. initial dermal and inhalation exposure estimates and LEV efficiencies for PROCs 1-20, see Table 5.3) is connected to the EASE categories which

The variability concerning the tool usage is a reflection of the quality of the documentation of the exposure situation (which is a source of uncertainty related to the scenario),

Work Package I.6 of the eteam project was developed to evaluate operational aspects of the usability and fitness for purpose of each of the first tier exposure assessment

• Tools appear conservative for volatile liquids and powders, in particular for high exposures levels. • However, in particular for TRAvs2 and vs3 care should be taken when

The author hereby grants the Federal Institute for Occupational Safety and Health (BAuA) the non- exclusive and royalty-free right of use without any restrictions regarding location