• Keine Ergebnisse gefunden

Correction: Mechanical properties of femoral trabecular bone in dogs

N/A
N/A
Protected

Academic year: 2022

Aktie "Correction: Mechanical properties of femoral trabecular bone in dogs"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

BioMed Central

Page 1 of 1

(page number not for citation purposes)

BioMedical Engineering OnLine

Open Access

Correction

Correction: Mechanical properties of femoral trabecular bone in dogs

Thomas Pressel*

1

, Anas Bouguecha

2

, Ute Vogt

3

, Andrea Meyer-Lindenberg

3

, Bernd-Arno Behrens

2

, Ingo Nolte

3

and Henning Windhagen

1

Address: 1Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1–7, 30625 Hannover, Germany, 2Institute of Metal Forming and Metal Forming Machine Tools, University of Hannover, Schönebecker Allee 2, 30823 Garbsen, Germany and 3Clinic for Small Domestic Animals, School of Veterinary Medicine Hannover, Bischofsholer Damm 15, 30173 Hannover, Germany

Email: Thomas Pressel* - thomas.pressel@gmx.de; Anas Bouguecha - bouguecha@ifum.uni-hannover.de; Ute Vogt - ute.vogt@tiho-

hannover.de; Andrea Meyer-Lindenberg - andrea.meyer-lindenberg@tiho-hannover.de; Bernd-Arno Behrens - behrens@ifum.uni-hannover.de;

Ingo Nolte - inolte@klt.tiho-hannover.de; Henning Windhagen - windhagen@annastift.de

* Corresponding author

Abstract

After the publication of this work [1], we became aware of the fact that the frequency of the ultrasound transmitter that we used for determining the elastic moduli of the trabecular bone specimens was not correctly specified. The oscillation frequency of the ultrasound transmitter was 2 MHz (and not 100 MHz as stated in our work) while we used a sampling rate of 100 MHz. In our publication, the oscillation frequency and sampling rate were confounded. Therefore also the statement in the discussion that we might have determined elastic moduli of trabecular bone tissue rather than the elastic properties of whole specimens because we used an ultrasound frequency >

2 MHz is wrong and has to be omitted.

For measurement, the cubic bone specimens were not immersed in Ringer's solution but only were kept moist all the time.

Apart from these corrections concerning the methods and interpretation of the data, the results reported in our publication and the conclusions are absolutely correct.

We apologize for the inconvenience that this inaccuracy may have caused.

References

1. Pressel T, Bouguecha A, Vogt U, Meyer-Lindenberg A, Behrens BA, Nolte I, Windhagen H: Mechanical properties of femoral trabecular bone in dogs. Biomed Eng Online 2005, 4:17.

Published: 07 December 2005

BioMedical Engineering OnLine 2005, 4:66 doi:10.1186/1475-925X-4-66

Received: 02 December 2005 Accepted: 07 December 2005 This article is available from: http://www.biomedical-engineering-online.com/content/4/1/66

© 2005 Pressel et al; licensee BioMed Central Ltd.

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Referenzen

ÄHNLICHE DOKUMENTE

As for the conductivity sensor, the result of calibration shows that a set of coefficient for the conversion from the frequency to the conductivity decided at the time of the

Methods Mechanical properties of PDMS are adjusted by adding different siloxanes, NPSNPs and further additives.. The NPSNPs have to be functionalized for embedding them into

PLAN OF STORAGE RES_ERVOIR; SECTIONS OE EMBANKMENT, BYEWASH, &c.; VALVE WELL, FOOT BRIDGE, FILTER BEDS, &C.; PORT GLASGOW WATERWORRS: EMEANKMENT, FILTERS, &C.;

One area where librarians ought to engage in serious research is long term digital archiving.. Librarians have long had responsi- bility for ensuring that

— and its different roles, from its apparently ornamental role in the Ionic order, to its more immediately conceptually-loaded role in Renaissance painting or Baroque

The author hereby grants the Federal Institute for Occupational Safety and Health (BAuA) the non- exclusive and royalty-free right of use without any restrictions regarding location

By testing four different models of economic growth in transition countries differentiated by the method of aggregation used to represent structural reforms, we can conclude that the

Given the abundance of non-muscle myosin II in the cap cells, we hypothesized that the greater increase in the length of the cap cells as compared to the neurons in our shape