Naming Convention

BACK

Files and folders have been named according to the following naming convention:

KINx_3yz.gif

x = Number of kicker magnet (1...5) y = type of measurement:

i - magnetic field (relative to maximum field strength in magnet center) L - difference of magnetic field between KINx and average from all five kicker magnets (relative to maximum field strength in magnet center) z = magnetic field direction (1...3)

1 - main field (vertical direction, x-axis of the beam) 2 - transversal field (horizontal, y-axis of the beam) 3 - longitudinal field (parallel to beam, z-axis) other naming convention (used for folders) KINxMaCb

x = Number of kicker magnet (1...5)

a = Number of magnet (1...5, ferrites, conductor, etc.) b = Number of chamber (1...5)

Actual state (March 8, 2001)

KIN1M5C6 - installed as ARIMA-KIN-1 KIN2M1C4 - installed as ARIMA-KIN-2 KIN3M4C1 - installed as ARIMA-KIN-3 KIN4M3C3 - installed as ARIMA-KIN-4 KIN5M2C2 - not installed, spare

Referenzen

ÄHNLICHE DOKUMENTE

The findings of the present study in individuals with suspected insufficiency of the HPA axis are 2-fold: 1) the age- and gender- specific z-score for DHEA-S is lower in

3 a Displacement field in the direction of the x-axis and b displacement field in the direc- tion of the y-axis calculated from binary pattern reference images with a

importer sometime next year and the new deals would enable Russia to provide almost 10 percent of China’s imported oil, likely making China the largest importer of Russian oil (it

Um sicherzustellen, dass die neue Firmware nicht verändert wurde, wird mit dem öffentlichen Schlüssel (mit dem Axis Produkt geliefert) überprüft, ob der Hashwert tatsächlich mit

Although the multipole corrector used in low voltage SEM (scanning electron microscope) successfully corrected the spherical and the chromatic aberrations, it is not suited for

In particular, taking stock of the accusations that US administrations consistently put forward in virtually every strategic document released in recent years concerning

The spectra were recorded in the region from 8.0 to 40.0 GHz with a conventional microwave spectro- meter 2 equipped with an 8m-absorption cell and employing 33

However, since we do not know how the steering with the QSM’s will work it’s better to try to adjust horizontally the WSX axis to ≤ 0.1 mrad with respect to the