• Keine Ergebnisse gefunden

Phase Imaging using Neutrons For particle physicists, neutrons are small massive particles with a confinement radius of about 10

N/A
N/A
Protected

Academic year: 2022

Aktie "Phase Imaging using Neutrons For particle physicists, neutrons are small massive particles with a confinement radius of about 10"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

July 2006

Research Highlight

Phase Imaging using Neutrons

For particle physicists, neutrons are small massive particles with a confinement radius of about 10-15 m and a distinct internal quark-gluon structure. In quantum mechanics, neutrons are described by de Broglie wave packets whose spatial extent may be large enough to show interference effects similar to what can be observed with visible laser light or highly brilliant x-rays from synchrotron sources. Measurements of the neutron wave packet's phase shift induced by different interaction potentials have a long and distinguished history in the exploration of the fundamental properties of quantum mechanics. If such phase sensitive measurements are further combined with neutron imaging approaches, two- or even three- dimensionally resolved spatial information on the quantum mechanical interactions of massive particles with matter can be obtained.

With our recent work, we have demonstrated how a grating based shearing interferometer can be efficiently used to retrieve such phase images with polychromatic neutron sources of little spatial and chromatic coherence. Figure 1 shows results for a test sample made of copper (Cu) and titanium (Ti) metal rods. Neutrons delivered at the new cold neutron imaging facility (ICON) at the Swiss Spallation Neutron Source were used.

Figure 1: (a) Conventional neutron attenuation image and (b) phase image of two metal rods.

The scale bar corresponds to 5 mm.

Due to the similar neutron capture cross-sections and the incoherent scattering lengths, there is not a large difference in the attenuation of the neutron beam in the rods (Fig. 1a). In Figure 1b, however, where the projected neutron nuclear phase shift is shown, a clear difference between Cu and Ti can be observed. It is interesting to note that Ti has a brighter color compared to the background, whereas Cu appears darker. This is due to the negative neutron scattering length density of Ti. Consequently, a negative phase shift is measured in the material.

Publications

Neutron phase imaging and tomography,

F. Pfeiffer*, C. Grünzweig, O. Bunk, G. Frei, E. Lehmann, and C. David, Phys. Rev. Lett. 96, 215505 (2006),

DOI: 10.1103/PhysRevLett.96.215505

Neutron Vision, David Lindley, Physical Review Focus 17, story 20 (2006).

* To whom correspondence should be addressed. E-mail: franz.pfeiffer@psi.ch

Referenzen

ÄHNLICHE DOKUMENTE

To assess this effect, we asked how the resolution depends on the number of images I and the photons per image P and therefore carried out additional synthetic experiments using

quantum liquids; crystal field splitting in magnetic systems; spin dynamics in high-T C superconductors; phase transitions and quantum critical phenomena; phonon density of

Precision measurements of properties of the neutron or its decay yield important parameters of the standard model of particle physics but are also used to search for new particles or

The most prominent macroscopic quantum mechanical effects in superconductivity are the well known zero electrical resistance and the Meissner effect (magnetic field expulsion), less

The moderate requirements on coherence and monochromaticity, the possibility to make large gratings of high quality and efficiency, and the easy alignment and low sensitivity of

Advanced phase contrast imaging using a grating interferometer X-ray tomographic microscopy is a powerful technique for fast, non-destructive, high-resolution, quantitative

Likewise, the DPC image shown in Figure 2f reveals complementary details of the soft tissue structure surrounding the otoliths, whereas only the highly absorbing structures

Using the uncorrected hybrid system matrix (right), the reconstructed images of the particle-position measurement are brighter if the particle sample is near to the centre of the FOV