• Keine Ergebnisse gefunden

PVC tube supporting wire

N/A
N/A
Protected

Academic year: 2022

Aktie "PVC tube supporting wire"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Rhizon samplers were originally designed as micro-tensiometers for soil science for seepage water sampling in the unsaturated zone some ten years ago

soil moisture

(Meijboom and Van Noordwijk 1991).

References

Meijboom, F., and M. Van Noordwijk

Seeberg-Elverfeldt, J., M. Schlüter, T. Feseker, and M. Kölling.(

. 1991. Rhizon soil solution samplers as artificial roots, p. 793-795. In L. Kutschera, E. Huebl, E. Lichtenegger, H.

Persson and M. Sobotnik [eds.], Root Ecology and its Practical Aplication 3. ISRR Symposium. Verein für Wurzelforschung, A-9020 Klagenfurt Austria.

subm.) A Rhizon in situ sampler (RISS) for pore water sampling from aquatic sediments. Limnology and Oceanography: Methods.

Seeberg-Elver feldt, J., and M. Schlüter. patent (subm.) Probennahmegerät zur simultanen Sammlung von Porenwasser aus benachbarten aquatischen Sedimentbereichen und Anwendung davon - Sampling device for simultaneous collection of pore water from related aquatic sediment areas and applications about it. Reference number: 10 2004 053 111.0-24. Germany

Fig. 9:

Porewater concentrations of silicic acid in the MUC tube above measured from both rhizon sampling and conventional sampling by pressure filtration of the sediments.

Comparison between rhizon sampling and conventional squeezing.

Material and Methods Applications

We successfully used these samplers for high resolution sampling from closed sediment cores. The Rhizons were inserted through 3mm holes in the liner walls. By this method very high resolution pore water profile samples may be taken without disturbance of the sediment structure. Since samples are collected in directly attached syringes or vacuumtubes, contact with ambient oxygen is avoided for anoxic environments, thus eliminating both, the need for glove box sampling and eliminating the need for cumbersome pressure filtration.

Outlook

Recently other Rhizon models with carbon fibre support that allow pushing in of longer filter lengths (20cm) without external support have been presented by the manufacturer Frits Meijboom (Rhizosphere Research Products, Wageningen, NL). A micro-version of the micro tensiometer is also available in the meantime with a tube diameter of 1mm such that even smaller sampling intervals are possible. Rhizon related news are found on our labmethods pages:

Http://www.geochemie.uni-bremen.de/koelling/rhizon.html

Discussion

Fig. 3: : Vacuum may be applied by either a needle inserted into a blank vacutube, a syringe with the plunger kept open by a spacer or by a peristaltic pump. The peristaltic pump shown (KC Denmark deep sea peristaltic pump) is suitable for underwater use.

Rhizon sampling

I II

III

PVC tube supporting wire

hydrophilic porous polymer

vacuum tube

syringe

peristaltic pump

needle

Luer-Lock connector silicon tube

Luer-Lock connector

Rhizon

I

III

liner wall II

100 200 300 400

21 18 15 12 9 6 3 0

Squeezing Rhizon

200 400 600 800

18 15 12 9 6 3 0

Depth[cm]

Squeezing Rhizon I Rhizon II

150 300 450

40 35 30 25 20 15 10 5 0

Squeezing I Squeezing II Rhizon

Silicic acid [µmol L-1]

A B C

Rhizon - an excellent pore water sampler

for low maintenance collection and filtration of small volume samples

Martin Kölling (1,2), Jens Seeberg-Elverfeldt (2,3), Michael Schlüter (2,3)

(1) Department of Geosciences, University of Bremen, Germany (2) DFG Research Center Ocean Margins, Bremen, Germany, (3) Alfred-Wegener-Institute for Polar and Marine Research, Bremerhaven, Germany, (koelling@uni-bremen.de/+49-421-218-3828)

University of Bremen

Department of Geosciences

Rhizons consist of a small microporous polymer tube (2.5mm diameter) supported by a stabilizing wire that is connected to a PVC-tube and a standard luer-lock connector.

The pore width of the tube is 0.15 micron. The stabilizing wire may be stainless steel, Nylon, PEEK, titanium or carbon fibre, depending on analytical needs.

Fig. 1: , 50mm length, 2.5mm

diameter (Rhizosphere Research Products, Wageningen NL).

The hydrophilic microporous tube (white) is supported by a nylon wire. The sampler is connected to Tygon tubing.

Rhizon Core Solution Sampler

We have introduced these samplers for the use in marine sediments and in saturated groundwater environments for direct pore water sampling.

Fig. 4: connected to a needle and inserted through the rubber stopper of a plain vacutube. This is the most basic setup for unattended collection of filtered pore water samples from sediments.

Rhizon CSS, Fig. 2:

to our knowledge the first attempt to collect pore water samples from marine sediments using rhizon soil moisture samplers..

Rhizon pore water sampling in marine sediment cores,

By attaching vacuum to the luer connector by either a syringe, a vacuumtube or a peristaltic pump, small volumes of pore water samples may be extracted from sediments without further maintenance. As a side effect of the 0.15 micron pore width of the polymer tube, the samples are automatically filtered.

Advantages

Rhizon pore water samplers are small, easy to use with minimum handling and maintenance effort.

Samples are filtered upon collection.

Many samples may be collected simultaneously.

High resolution sampling is easy.

When sampling in situ or sampling from closed cores no glove box setup is necessary to maintain anoxic conditions.

Low sampling speed and low sampling volume may be compensated by multiple samplers per depth and by simultaneous sampling

Disadvantages

Low flow rates, low sample volume per time (some 10 mL per hour). Rhizons are clearly the wrong samplers when large sample volumes are needed.

Possible sorption losses on tubing.

Possible temperature change upon sampling.

Tiny fragile devices not suitable for rough use.

Introduction

Fig. 8: Multicorer liner tube

on a Polarstern Cruise with rhizons installed through predrilled holes in the liner wall. Sampler connectors are sealed by blue caps until syringes are attached. Vertical distance of sampling points is 2 cm.

Porewater sampling from MUCs.

Fig. 5: connected to a 20 mL

disposable syringe. Vacuum is simply applied by pulling the plunger and keeping it in place with a spacer.

Rhizon Core Solution Sampler Fig. 7: using Rhizon

samplers attached to a needle and blank vacutubes. For special purposes also preloaded vacutubes may be used

Pore water sampling from a core liner

Fig. 6: . A liner driven is into

wadden sediments then one wall is cleared and rhizon samplers are pushed through predrilled holes in the wall. Sampling by disposable syringes with spacer. Despite all the “dirt” on the picture the samples are clean and 0.15micron filtrated

Manual semi In situ sampling

Referenzen

ÄHNLICHE DOKUMENTE

Betriebsdruck : siehe Tabelle unten (bitte bei PVC besonders beachten: Druckangaben immer bei 20°C) Vakuum : alle Größen 0,9bar (bitte bei PVC beachten: Vakuumangaben immer bei

[r]

La palette de couleurs composée de plus de 100 tonalités de la carte RAL, colorées dans la masse par extrusion, les cinq dimensions différentes avec possibilité de combinaison de

Analyte of eDiagnosis COVID-19 Antigen Rapid Test Kit Saliva/Swabs is nucleocapsid protein antigen from SARS-CoV-2 in oropharyngeal throat swabs, nasopharyngeal swabs, nasal swabs

on Bayesian sampling theory and leads to estimates of group utility accounting for sampling and measurement error.. The results of the estimation may be directly incorporated

When the sample is filtered, unscrew the upper chamber and pour the filtered sample into the sampling bottles.. For cations, acidify the filtered water sample using a few drops

Feret Angle of statically cultured EC was greater than of EC cultivated under

We extend their Theorem 11 (which corresponds to the case h = 0), reflecting the advantage of the Picard-type scheme: The error induced by the approximation of the