1 / 5 EL-9950 upgrade manual Nov.28, 2014 Upgrade to ver1.2

N/A
N/A
Protected

Academic year: 2022

Aktie "1 / 5 EL-9950 upgrade manual Nov.28, 2014 Upgrade to ver1.2"

Copied!
5
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

EL-9950 upgrade manual

Nov.28, 2014 Upgrade to ver1.2 from ver1.1 with CE-LK4.

Step1.

Connect cable (CE-LK4) to PC.

Step2.

Execute "CE-LK4 for EL-9950" on PC.

Step3.

Connect cable to EL-9950.

Step4.

Turn on EL-9950 and press key.

If the following screen is displayed, please press [CL] key twice on EL-9950.

[CL] [CL]

Step5.

Select "Communication Port" at Link menu.

Step6.

Click "Auto Setting" button.

+-

×÷

__

P R E S S [ C L ] K E Y T O C L E A R A L L D A T A

P R E S S [ O N ] K E Y T O C A N C E L

(2)

Step7.

Click "OK" button.

Step8.

The following window is displayed. And a progress bar is extended.

When setting is finished, the window is closed automatically.

Note:

If the following window "No response" is displayed, check whether a cable is connect properly.

Then do it again from Step6.

Sep9.

Select "Repro" at Tools menu.

Step10.

Click "Browse" button .

If "el9950_ver120.bin" is already selected, go to Step12.

(3)

Step11.

Select "el9950_ver120.bin"

Step12.

Click "Send" button.

Step13.

Click "OK" button.

Step14.

The following window is displayed.

After 15seconds, the following screen is displayed on EL-9950.

R E - P R O G R A M R E C E I V E

D A T A

(4)

Note:

If the following window "No response" is displayed , check whether a cable is connect properly.

Please carry out recovery operation(*1) of EL-9950. (Refer to APPENDIX)

If the following window "This is an older version...." is displayed, it is not necessary to upgrade.

Because it is already ver1.2.

Step15.

A progress bar is extended.

A black circle is indicated on EL-9950 during the transfer. After 30 seconds, the first circle is displayed.

The total transfer time is about 4 minutes.

Note:

If "x" mark is indicated on EL-9950, Please carry out recovery operation(*1) of EL-9950.

(Refer to APPENDIX)

Step16.

When transfer is finished, the following window is displayed. Click "OK" button.

EL-9950 is turned off automatically

.

R E - P R O G R A M R E C E V E

D A T A

R E - P R O G R A M R E C E V E

D A T A X

(5)

Step17.

Remove the cable from EL-9950.

Step18.(Last)

Turn on EL-9950.

Press [2ndF][OPTION] and [cos] key, then the following screen is displayed.

Check name and version. (EL-9950 Ver1.2)

APPENDIX

(*1) Recovery operation of EL-9950 Step A1.

Open and close the battery cover of EL-9950.

Step A2.

If the following screen is displayed, recovery is finished. Please go to Step12.

If it is not displayed even if it waits for 5 seconds, please turn on EL-9950.

Step A3.

If the following screen is displayed, please press [CL] key twice.

Step A4.(Last)

If the screen with only an underline is displayed, recovery is finished. Please go to Step12.

P R E S S [ C L ] K E Y T O C L E A R A L L D A T A

P R E S S [ O N ] K E Y T O C A N C E L

__

R E - P R O G R A M R E C E I V E W A I T

Referenzen

ÄHNLICHE DOKUMENTE

Denn während das (Arbeits-)Leben für einige bequemer wird durch die digitale Transformation, werden andere ohne Arbeit dastehen oder überwacht und getaktet von Apps vor

executed using the data, and the function equation has been stored in Y0 to Y9, input that equation number for the equation items.. Answers are displayed on the screen, where a,

Thousands of initiatives are contributing inspiring, creative, and necessary solu - tions to urgent global issues such as climate change, migration, urbanization, and the need

Using an ohmmeter from output common to each output (with output loads disconnected), check for shorted. rectifiers or

We use Erd¨ os’ probabilistic method: if one wants to prove that a structure with certain desired properties exists, one defines an appropriate probability space of structures and

The following theorem (also from Chapter 2 of slides) has an analogous formulation..

safekeeping. The pynabyte utility DYNASTAT displays your current system configuration. 'The steps described below will change the drive assignrnentsso that you will

It is intended to be the firmware reference manuaL and to be used by the advanced microprogrammer of the Rikke MathiLda system.. WideStore, WS, is the common