• Keine Ergebnisse gefunden

Scale-up of the production of highly reactive biogenic magnetite nanoparticles using Geobacter sulfurreducens

N/A
N/A
Protected

Academic year: 2022

Aktie "Scale-up of the production of highly reactive biogenic magnetite nanoparticles using Geobacter sulfurreducens"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Scale-up of the production of highly reactive biogenic magnetite nanoparticles using Geobacter sulfurreducens

James M. Byrne, H. Muhamadali, V. S. Coker, J. Cooper, J. R. Lloyd (2015) Accepted for publication in J R Soc Interface

The data contained within this data set is arranged according to the Figure number as it appears in the manuscript. Full details identifying the x- and y-axes are included in the tab delineated .txt files:

Figure_1a.txt - Growth rate of Geobacter sulfurreducens with varied electron donor: accetor ratios Figure_1b.txt - Fe(III) reduction rates of bacteria produced on varied electron donor: acceptor ratios

Figure_1c.txt - XRD of the products of microbial reduction of ferrihydrite by Geobacter sulfurreducens

Figure_2.txt - Growth of Geobacter sulfurreducens in a 5 l bioreactor Figure_3a.txt - G. sulfurreducens Growth curves in 100 ml bottles Figure_3b.txt - G. sulfurreducens Growth curves in 5 l bioreactor Figure_3c.txt - G. sulfurreducens Growth curves in 50 l bioreactor Figure_4a.txt - Change in Fe(II)/Fe(Total) over time

Figure_4b.txt - XRD of the products of microbial reduction of ferrihydrite by Geobacter sulfurreducens in different volume containers

Figure_5a.txt - X-ray absorption spectra (XAS) of samples obtained through microbial reduction of ferrihydrite by Geobacter sulfurreducens in different volume containers

Figure_5b.txt - X-ray magnetic circular dichroism (XMCD) of samples obtained through microbial reduction of ferrihydrite by Geobacter sulfurreducens in different volume containers

Figure_6.txt - Biogenic magnetite reactivity with Cr(VI) Included in Supplementary Information

Figure_S2.pdf - Transmission electron microscopy imaging of end product of Fe(III)- reduction by Geobacter sulfurreducens. (a) 10 ml volume vessel, (a-i) image displays spherical particles, most likely magnetite, (a-ii) electron diffraction indicates presence of magnetite (red) and hematite (green), (a-iii) hematite crystal clearly distinguishable from spherical magnetite. (b) 10 L volume vessel sample. (b-i) spherical magnetite of similar size to 10 ml samples, (b-ii) electron diffraction indicates presence of hematite (green), magnetite (red) and siderite (blue); (b-iii) several crystals were observed which were much larger than the relative size of the magnetite that have been attributed to siderite.

Figure_S3a.txt - Mössbauer spectroscopy of biogenic magnetite produced in 100 ml volume vessel Figure_S3b.txt - Mössbauer spectroscopy of biogenic magnetite produced in 10 l volume vessel

Referenzen

ÄHNLICHE DOKUMENTE

The 1941 Hungarian Marriage Law – officially Law No. XV of 1941 – that banned marriages between Jews and non-Jews and the resulting race defilement cases dif- fered significantly

The low temperature elastic and magnetic properties of synthetic polycrystalline, multi-domain magnetite have been analysed using Dynamic Mechanical Analysis (DMA),

http://www.washingtonpost.com/wp-dyn/content/article/2010/11/25/AR2010112503116_pf.html.. In particular, I agree that an American citizen who is a senior al Qaida leader outside

However, (b) if saline fluid exsolves during decompression and bubbles nucleate on magnetite crystals owing to favorable wetting properties, then (c) magnetite-bubble pairs form

In both microaerobic ammonium medium and an- aerobic nitrate medium, ΔMgfnr mutant cells displayed WT-like growth and magnetic response (C mag ) (data not shown) and produced

Magnetite-melt partitioning experiments showed that at fixed alumina saturation index and temperature the partition coefficient of vanadium between magnetite and

Interestingly, MamB transport activity seems not to be required for magnetosome membrane invagination, as a strain synthesizing the inactive MamB MSR-1 D50A protein was still able

The goal of this study was to apply this technique of pulses parallel and antiparallel to a north-south biasing field to test whether bats use freely rotating magnetite as