• Keine Ergebnisse gefunden

Detection of Adducts with Matrix Clusters in the Positive and Negative Ion Mode MALDI-TOF Mass Spectra of Phospholipids

N/A
N/A
Protected

Academic year: 2022

Aktie "Detection of Adducts with Matrix Clusters in the Positive and Negative Ion Mode MALDI-TOF Mass Spectra of Phospholipids"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Detection of Adducts with Matrix Clusters in the Positive and Negative Ion Mode MALDI-TOF Mass Spectra of Phospholipids

Marijana Petkovi´ca,b, J¨urgen Schillera,

Matthias M¨ullera, Rosmarie S¨ußa, Klaus Arnolda, and J¨urgen Arnholda

aInstitute of Medical Physics and Biophysics, Medical Faculty, University of Leipzig, Leipzig, Germany

bPresent address: Department of Physical Chemistry, Institute of Nuclear Sciences “Vinˇca”, Belgrade, Serbia Reprint requests to Dr. Marijana Petkovi´c.

Fax: +381 11 244 7207. E-mail: marijanapetkovic@vinca.rs Z. Naturforsch.2009,64b,331 – 334;

received December, 1, 2008

It is usually accepted that neutral phospholipids (PLs) gen- erate singly positively charged ions, whereas negative PLs are easily detectable in the negative ion mode when analysed by matrix-assisted laser desorption and ionisation time-of- flight mass spectrometry (MALDI-TOF MS). In this study, we demonstrate that some caution is required in the inter- pretation of MALDI-TOF mass spectra of PLs, since also neutral PLs have appeared to be detectable in the negative ion mode as well. Neutral and negatively charged phospho- lipids can generate adducts with the most commonly used matrix – 2,5-dihydroxybenzoic acid – yielding singly neg- atively charged ions that are detectable in the spectra. This further contributes to the complexity of the spectra and po- tentially leads to severe misinterpretation, particularly when unknown mixtures of PLs are analysed by MALDI-TOF MS.

Key words:Phospholipids, MALDI-TOF MS, Adducts, Matrix Clusters, Positive Ion Mode, Negative Ion Mode

Referenzen

ÄHNLICHE DOKUMENTE

In summary, as it follows from preceding analysis, in the negative glow the excitation of He states occurs mainly via He 2 + dissociative recombination while in the positive

Nach einer solchen Einführung wird allerdings –a für viele Lernenden selbst dann negativ bleiben, wenn a für eine negative Zahl stehen kann.. Eine Addition und eine

Erhalt und Entwicklung ästuartypischer Prozesse und Funktionen zur Entwicklung naturnaher abiotischer Bedingungen, vielfältiger hydromorphologischer Strukturen und

A four-component dusty plasma consisting of electrons, ions, and negatively as well as positively charged dust grains has been considered. Shock waves may exist in such a

It is usually accepted that neutral phospholipids (PLs) gen- erate singly positively charged ions, whereas negative PLs are easily detectable in the negative ion mode when analysed

The formation rates of positive and negative ions with a size of 1.6 nm, determined from the neutral cluster and air ion spectrometer (NAIS) ion mode measurements,

This work has been digitalized and published in 2013 by Verlag Zeitschrift für Naturforschung in cooperation with the Max Planck Society for the Advancement of Science under

The following are the most significant positive impacts of dams: electricity generation, recreation and tourism, water and water sports, moderating greenhouse gas emission, fish