5.2009 | LANDTECHNIK 350 CROPPING AND MACHINERY

Latsch, Roy; Sauter, Joachim and Knížatová, Monika

Dock-control via microwave — energetic and

fi nancial considerations

A powerful microwave device was tested for the non-contact control of dock weed on grass- land. The optimum treatment times for a maximum re-sprout rate of 20 % were determined in three different trial variants. Energy requirement, costs and fuel consumption were also esta- blished.

Keywords

Broad-leafed dock plants, rumex, weed-control, microwave

Abstract

Landtechnik 64 (2009), no. 5, pp. 350 - 353, 3 fi gures, 1 table, 2 references

Broad-leaved dock (Rumex obtusifolius) is a common but unwelcome plant in meadows and pastures, as cattle fi nd it un- palatable and tend to avoid it. This is due to high levels of oxa- lates and tannins in the plant. The feed value according to [1]

is given as „1“ (very low). Because of their vigorous growth ha- bit dock species are very competitive and are therefore seen as appropriating the space and nutrients of valuable fodder crops.

Reserves stored in the well-developed roots of dock plants form the basis of their huge regenerative capacity when damaged, e.g. after moving or grazing.

The chief methods of dock control in organic farming are ma-

nual. On the one hand the fl ower heads are removed from the fi elds to prevent self-seeding, and on the other they are con- trolled directly by digging up and removing the dock roots.

Can microwaves provide a solution?

Organic farming is interested in a largely automated procedure for dock control. Microwave technology is a non-contact method of heating dock plant roots in the ground to such a high tempe- rature that proteins denature, DNA is destroyed and hence the plant dies. Heating time and energy input are the key factors in the success of this procedure.

The prototype and trial variants

A self-propelled prototype was built following various preli- minary trials with positive outcomes (fi gure 1). Its principal components are a generator (1), a high-voltage unit with coo- ling fan (2) and a hydraulic adjustable head with magnetrons and waveguide exits (3). Twelve magnetrons together supply an output of 18 kW. Each magnetron carries the microwaves in a separate open-ended waveguide. The exits are arranged in two columns of six lines, giving rise to a total exit area of 18 × 18 cm. Ground sensors ensure that heating is possible only when the microwave head is fully lowered. The openings are covered by a replaceable mica sheet to protect the open waveguides from dirt.

Prior to treatment isolated dock plants were marked on the study areas and measured with a high-precision RTK GPS.

Plant treatment was carried out with different heating times in order to identify an optimum time. Soil moisture on the sites was also determined.

Three variants were tested:

Variant 1: Permanent heating at full power output

(100 % power output)

Variant 2: „Pulsed“ heating at full power output (pulse).

Here the heating time was interrupted at intervals with

(2)

5.2009 | LANDTECHNIK

351

that with permanent heating (F1.25 = 6.26, p = 0.02). When heating time was increased by one second, the plant mortality rate rose by approximately 3 % (F1.25 = 122.78, p < 0.001).

Energy used

Heating energy is calculated from the magnetron power output [W] multiplied by the heating time used [s]. Heating energy/area [Ws/cm2] is therefore a measurement of the amount of energy needed in this machine confi guration to obtain a particular mortality rate (fi gure 3). The target value of maximum 20 % re-sprouting is achieved at approximately 1550 Ws/cm2 (0.0004 kWh/cm2). The dispersion of the data indicates that the site (series) plays a subordinate role in suc- cessful treatment.

Self-propelled microwave-prototype. 1 = generator, 2 = high-voltage unit with cooling fan, 3 = hydraulic adjustable head with magnetrons and waveguide exits. Photo: ART

Fig. 1 the aim of obtaining improved temperature distribution in

the root: e.g. heat 10 s — wait 10 s — heat 10 s etc.

Variant 3: Permanent heating at 25 % power output

(25 % power output). This setting was intended to clarify whether energy optimisation of the procedure was possi- ble by an appropriate extension of heating time at reduced heat output

Statistical considerations and the heating times determined

265 plants of variant 1, 157 of variant 2 and 86 plants of variant 3 fed into the statistical considerations. The target value for the re-sprouting rate was set at a maximum of 20 % (fi gure 2). This allowed optimum theoretical heating times to be calculated by linear regression. These were very close for unpulsed (28 s) and pulsed (27 s) heating time. At 25 % po- wer output the heating time almost quadrupled at 101 s. These theoretical values served as a basis for variant comparison in energy terms.

The results of variants 1 and 2 were compared in a GLS model. Soil moisture and heating time were continuous varia- bles. A distinction was also made between pulsed and unpulsed heating times. The F-test revealed no signifi cant interactions between the parameters of soil moisture, heating time and pulse. Soil moisture only exerted a slight infl uence on the re-sp- routing rate of dock roots. With the available variation range of soil moisture values there is evidence of only a slight tendency towards higher re-sprouting rates with increased soil moisture (0.13 % higher re-sprouting per 1 % increase in soil moisture).

Heating time and pulsing had a signifi cant effect on re-- sprouting rates. On average the treatment of plants at pulsed heating intervals was approximately 5 % more effective than

Fig. 2

0 10 20 30 40 50 60 70 80 90 100

5 10 15 20 25 30 35 40 60 80 100 120 140

Heizzeit [s]

heating time [s]

Wiederausgetriebene Pflanzen [%] resprouting plants [%]

permanent gepulst/pulse 25% Leistung/output

Linear (permanent) Linear (gepulst/pulse)

ntotal = 508 Pflanzen/plants

y = -3.0316x + 104.46 R2= 0.95

y = -2.6449x + 91.891 R2= 0.93

y = -0.4231x + 62.846 R2= 0.67

Linear (25% Leistung/output) Zielwert/aim

Percentage of re-sprouting plants (with standard digression) after different microwave heating times (18 kW) in 2008

(3)

5.2009 | LANDTECHNIK 352 CROPPING AND MACHINERY

Fuel input and costs

The question of the requisite fuel input was answered in purely mathematical terms. In order to determine same the following assumptions were made:

Effi ciency in microwave generation is around 50 % of the power supplied. A generator with double the electrical output of the microwave heating capacity is therefore required. Ac- cording to [2], 272 g fuel/kWh is needed for a diesel unit to generate 36 kWh of power. Diesel fuel has an average density of 0.83 kg/l. The cost of diesel was estimated at EUR 1.10 per litre.

To the heating time of variant 2 (pulsed) were added an average 6 s in standby mode for interval out-time. The cost pro- jection shown in table 1 can therefore be carried out for actual energy input.

Depending on the variant selected, considerable quantities of fuel should be reckoned with for the actual heating process in dock control. Assuming moderate population densities of 2000 dock plants/ha, 160–220 l diesel/ha would be required.

800–1 100 l diesel would be necessary for extremely weedy po- pulations of 10 000 dock plants.

In addition to the actual cost of fuel for heating, the total cost of the procedure also has to include the cost of fuel for idling between individual treatments, the power consumption of the towing vehicle and purchase costs as well as miscellaneous fi xed and variable costs. Due to the extended heating times in the pulsed and the reduced-power variant the area treated per hour is also comparatively lower, which is refl ected in the cost of the procedure.

Conclusions

The fi eld trials carried out in 2008 show that the use of micro- wave to control dock plants does work in principle. The target mortality rate of 80 % can be achieved with 18 kW microwave output in a heating time of 28 s. If heating takes place at timed intervals by switching the microwave on and off, this slightly reduces the actual heating time to 27 s compared with the con- tinuously heating variant. Here account must also be taken of the time when the microwave device pauses even though the generator is running. At 25 % power output the heating time has less than quadrupled at 101 s. This variant therefore does better in a relative comparison. The indication is that longer

Energy use and costs of the microwave device Heating

power

Generator- output

Heating time

Interval out-time

Fuel consumption per dock plant

Fuel cost per dock plant

kW kW s s l

Variant 1 (100 %) 18,0 36,0 27,9 0,09 0.10

Variant 2 (pulsed) 18,0 36,0 27,2 6,0 0,11 0.12

Variant 3 (25 %) 4,5 9,0 101,3 0,08 0.09

Table 1 Fig. 3

y = -16.675x + 1881.2 R2 = 0.81

200 400 600 800 1000 1200 1400 1600 1800 2000 2200

0 10 20 30 40 50 60 70 80 90 100

Wiederaustrieb [%]

resprouting plants [%]

Heizenergie/Fläche [Ws/cm2 ] heating energy/area [Ws/cm2 ]

permanent Serie 1 permanent Serie 2 permanent Serie 3 gepulst/pulse Serie 1 gepulst/pulse Serie 2 gepulst/pulse Serie 3 25% Leistung/output total

Zielwert/aim

Heating energy input/area and re-sprouting plants in all fi eld trial series

(4)

5.2009 | LANDTECHNIK

heating times at lower power output are more effi cient from an energy point of view. Microwave technology in the form of a self-propelled high-performance unit is impractical, however, because of its high energy consumption.

Literature Books are signed with

[1] Klapp, E., P. Boeker, F. König und A. Stählin: Wertzahlen der Grünland- pfl anzen. Das Grünland. Bd. 2, Schaper-Verlag, Hannover, 1953, S. 38–40 Rinaldi, M., S. Erzinger und R. Stark: Treibstoffverbrauch und Emissionen [2]

von Traktoren bei landwirtschaftlichen Arbeiten. Forschungsanstalt Agro- scope Reckenholz-Tänikon ART, FAT-Schriftenreihe, Nr. 65, Tänikon, 2005

Authors

Dr. Roy Latsch and Dr. Joachim Sauter are research associates at Agroscope Reckenholz-Tänikon ART, Tänikon, CH-8356 Ettenhausen, Switzerland, E Mail: roy.latsch@art.admin.ch

Ing. Monika Knížatová is a research associate at Centrum výskumu živocíšnej výroby Nitra, 949 92 Nitra, Slovakia

Collaboration

This project was carried out in collaboration with partners Odermatt Landmaschinen AG, Hunzenschwil, and Gigatherm AG, Grub, both Swit- zerland

353

Referenzen

ÄHNLICHE DOKUMENTE

Because of temporal variability in the availability of solar and industrial process heat, thermal storage systems are key components for the effective utilisation of this heat in

In the present paper, the sensitivity of input parameters in heating energy demand simulation is analyzed, be it related to spatial model geometry, building physics, or occupant

The fiction of Jules Verne becomes the declared goal: according to Fed- eral Minister of Education and Research Anja Karliczek, green hydrogen is the energy source of the future,

Zum einen werden die Blütenstände der Pfl anzen von den Feldern entfernt, um die Verbreitung durch Samen zu verhindern.. Zum anderen erfolgt die direkte Be- kämpfung durch

system of a coke plant by implementing the reaction mechanism and the combustion kinetics with the help of the CFD package FLUENT 6.3. In the latest simulations the Eddy

UBISI 2004 Symposium / March 2004 / www.alp.admin.ch.. New developments in heating technology for food preservation

The main idea is to use heating foils on the surface of the bottle and then find good spacial and temporal heating patterns to achieve a uniform, fast heating of the liquid..

Abstract – At the Paul Scherrer Institute a high temperature inductive heating furnace, which can heat fuel samples up to 2300°C, has been developed in order to study