• Keine Ergebnisse gefunden

Catalogue valeurs U

N/A
N/A
Protected

Academic year: 2022

Aktie "Catalogue valeurs U"

Copied!
24
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Catalogue valeurs U

Détermination

simple de la

valeur U d’éléments

(2)
(3)

GÉNÉRALITÉS ET MÉTHODE . . . . 5

CALCUL DE LA VALEUR U . . . . 7

MARCHE À SUIVRE . . . . 11

DÉTERMINATION DE LA VALEUR U D’UN ÉLÉMENT DE CONSTRUCTION . . . . 13

SOMMAIRE

(4)
(5)

GÉNÉRALITÉS ET MÉTHODE

LA CHALEUR EST UNE FORME D’ÉNERGIE. SON FLUX EST TOUJOURS DIRIGÉ DES TEMPÉRATURES LES PLUS ÉLEVÉES VERS LES TEMPÉRATURES LES PLUS BASSES. DES ÉLÉMENTS TELS QUE PLANCHERS, PAROIS, DALLES, TOITS, FENÊTRES ET PORTES OPPOSENT UNE CERTAINE RÉSISTANCE AUX ÉCHANGES THERMIQUES. LE FLUX DE CHALEUR QUI TRAVERSE UN ÉLÉMENT EST DÉFINI PAR LE COEFFICIENT DE TRANSMISSION THERMIQUE U (VALEUR U).

Le transfert surfacique (h) et la conductivité thermique (λ Le transfert surfacique (h) et la conductivité thermique (λ Le transfert surfacique (h) et la conductivité thermique ( ) λ) λ influencent la valeur U d’un élément.

Les phénomènes suivants influencent la valeur U d’un élément :

• Transmission de chaleur entre l’air intérieur et l’élément.

Ce processus est décrit par le coefficient de transfert de chaleur surfacique intérieur hi

• Conduction de chaleur à l’intérieur d’un élément.

Le paramètre déterminant est ici la conductivité thermique λ (lambda) des différents matériaux

• Transmission de chaleur entre l’élément et l’air extérieur.

Ce processus est décrit par le coefficient de transfert de chaleur surfacique extérieur he

Lorsque la valeur U diminue, les besoins d’énergie pour le chauffage baissent proportionnellement et les températures superficielles augmentent. Il en résulte une amélioration du confort de l’habitat et une réduction des risques de condensation à la surface des éléments, phénomène qui se traduit par l’apparition de taches grisâtres, de champignons et d’odeurs de moisi caractéristiques.

La Norme SIA 180 « Protection thermique, humidité et climat intérieur dans les bâtiments » présente des valeurs maximales pour les coefficients de transmission thermique, du point de vue du confort et de la protection contre l’humidité.

La Norme SIA 380/1 « L’énergie thermique dans le bâtiment » présente des valeurs limites et des valeurs cibles pour les coef­

ficients de transmission thermique d’éléments plans.

Ces normes ainsi que les prescriptions cantonales sur l’isolation thermique précisent les limites supérieures admissibles des valeurs U.

On peut formuler la règle suivante : plus la valeur U est petite, meilleure est l’isolation thermique.

L’unité physique de la valeur U est le watt par mètre carré et degré Kelvin : W/(m

2

· K).

La valeur U est le quotient de la densité de flux thermique qui traverse, en régime stationnaire, l’élément de construction considéré par la différence de température entre les deux ambiances contiguës à cet élément. Le coefficient de transmission thermique d’un élément est l’inverse de sa résistance totale.

Transfert de chaleur surfacique extérieurhe

Transfert de chaleur surfacique intérieurhi

Conductivité thermique λ

(6)
(7)

CE CHAPITRE PRÉSENTE LA MÉTHODE DE CALCUL DE LA VALEUR U POUR DES CONSTRUCTIONS SIMPLES TELLES QUE DES ÉLÉMENTS HOMOGÈNES . IL CONTIENT LES BASES NÉCESSAIRES ET LES PA­

RAMÈTRES INDISPENSABLES, À SAVOIR LES COEFFICIENTS DE TRANSFERT DE CHALEUR SURFACIQUE, LES RÉSISTANCES THERMIQUES DES LAMES ET LES CARACTÉRISTIQUES DES MATÉRIAUX . IL DONNE ÉGALEMENT QUELQUES INDICATIONS SUR LA FAÇON DE PROCÉDER LORS DE CONSTRUCTIONS PLUS COMPLEXES, DANS LESQUELLES PEUVENT INTERVENIR DES ÉLÉMENTS NON­HOMOGÈNES, DES PONTS THERMIQUES, DES FAÇADES VENTILÉES OU DES CHAUFFAGES PAR LE SOL .

CALCUL DE LA VALEUR U

ÉLÉMENTS HOMOGÈNES

Par éléments homogènes, on entend des constructions constituées de plusieurs couches de matériaux posées les unes contre les autres . Par opposition, on parle d’éléments non­homogènes lorsque des interruptions régulières surviennent, dues à des éléments tels que poutrelles en acier, piliers en béton ou chevrons intercalés (chap . 2 .2) .

Pour autant que les couches de matériaux soient connues avec précision, la valeur U d’éléments de construction existants ou assainis sera calculée selon la formule suivante :

Crépi intérieur Brique terre cuite Isolation thermique, p. ex. λ = 0.036 W/(m·K) 16 cm ou 2 × 8 cm Brique terre cuite Crépi extérieur

he = 25 W/(m2·K)

0.015 0.15 0.44 0.70 d =

λ =

m W/(m2·K) 0.16

0.036

0.02 0.12 0.44 0.87

e i

hi = 8 W/(m2·K)

U= 1

1 hi+d1

𝜆𝜆𝜆𝜆1+d2

𝜆𝜆𝜆𝜆2+…+Rg+…+dn

𝜆𝜆𝜆𝜆n+ 1 he

W/(m2·K)  

U= 1

1 8+ 0.02

0.87+ 0.12 0.44+ 0.16

0.036+0.15 0.44+0.015

0.70 + 1 25

 

U= 1

5.26W/(m2·K) = 0.19 W/(m2·K)

U = 1

1 h

i

+ d

1

𝜆𝜆𝜆𝜆

1

+ d

2

𝜆𝜆𝜆𝜆

2

+…+R

g

+…+ d

n

𝜆𝜆𝜆𝜆

n

+ 1 h

e

W/(m

2

·K)  

U = 1

1

8 + 0.02 0.87 + 0.12 0.44 + 0.16 0.036 + 0.15

0.44 + 0.015 0.70 + 1 25

 

U = 1

5.26 W/(m

2

·K) = 0.19 W/(m

2

·K)

d1…dn

Épaisseur de la couche du matériau correspondant, en m hi, he

Coefficients de transfert de chaleur surfacique, en W/(m2 · K) λ1…λn

Conductivité thermique du matériau correspondant, en W/(m · K) Rg

Résistance thermique de couches d’air

EXEMPLE DE CALCUL DE LA VALEUR U : MAÇONNERIE À DOUBLE PAROI

(8)
(9)

CALCUL DE LA VALEUR U

Lambrissage

Lambourdage/vide pour conduites Pare-vapeur

Isolation thermique

Chevron Sous-toiture Contre-lattage Couche ventilée Lattage Couverture

i e

Revêtement intérieur

Lambourdage/vide pour conduites Pare­vapeur

Isolation thermique (ép . variable) Isolation thermique (ép . fixe) Traverse

Panneau de fibres de bois Couche ventilée

Revêtement extérieur

i e

ÉLÉMENTS NON-HOMOGÈNES

Dans les éléments non­homogènes, une, voire plusieurs couches n’occupent pas l’entier de la surface, mais sont interrompues à distance régulière par d’autres éléments, en général meilleurs conducteurs de chaleur . Il faut tenir compte de telles interruptions, car la valeur U qui en résulte est moins bonne . La Norme SN EN ISO 6946 présente une méthode simplifiée pour le calcul de la résistance thermique d’un élément composé de couches homo­

gènes et non­homogènes .

Lors de constructions complexes, ainsi que lors de ponts thermiques fréquents (p . ex . sous­construction en aluminium de façades ventilées), la valeur U sera déterminée soit par des mesures, soit par un certificat, ou à l’aide de logiciels spécifiques ou encore grâce au Catalogue des ponts thermiques .

Élément neuf Élément existant

Nouvelle couche d’isolation Couche d’isolation existante Épaisseur du matériau e =extérieur

i =intérieur

(10)
(11)

21

Béton, brique ciment

Brique silico-calcaire Brique terre cuite Béton cellulaire Construction en bois

Construction en métal Assainissements tous les types de murs

> 30 cm, isolation

therm. homogène 18 18 ≤ 18 ≤ 18 30 cm, isolation therm. non-homogène ≤ 18 cm, isolation therm. homogène

8≤12cm, isolation therm. non-homogène 8≤12cm, isolation therm. non-homogène 4 ≤ 8 cm, isolation therm. homogène

1 1 1

1 ≤ 2cm, avec nvelle isolation therm. non-homogène 0

0 ≤ 1cm, avec nvelle isolation therm. homogène

TABLEAU T6 Valeurs U W/(m2K) ÉLÉMENT DE CONSTRUCTION :

ÉP. ISOLANT (M) d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20 d = 0.22 d = 0.24 d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Conductivité thermique λ

0.046 0.390.390.39 0.340.340.34 0.300.300.30 0.27 0.25 0.22 0.21 0.190.190.190.190.190.19 0.180.180.180.180.180.18 0.170.170.170.170.170.17 0.150.150.150.150.150.15 0.140.140.140.140.140.14 0.130.130.130.130.130.13 0.044 0.37 0.32 0.29 0.26 0.24 0.21 0.20 0.180.180.180.180.180.18 0.170.170.170.170.170.17 0.160.160.160.160.160.16 0.150.150.150.150.150.15 0.140.140.140.140.140.14 0.120.120.120.120.120.12 0.042 0.36 0.31 0.28 0.25 0.23 0.20 0.190.190.190.190.190.190.19 0.170.170.170.170.170.170.17 0.160.160.160.160.160.160.16 0.150.150.150.150.150.150.15 0.140.140.140.140.140.140.14 0.130.130.130.130.130.130.13 0.120.120.120.120.120.120.12 0.040 0.340.34 0.300.30 0.27 0.24 0.22 0.20 0.180.180.180.180.180.18 0.170.170.170.170.170.17 0.160.160.160.160.160.16 0.150.150.150.150.150.15 0.130.130.130.130.130.13 0.120.120.120.120.120.12 0.11 0.038 0.33 0.29 0.26 0.23 0.21 0.190.190.190.190.190.190.190.19 0.170.170.170.170.170.170.170.17 0.160.160.160.160.160.160.160.16 0.150.150.150.150.150.150.150.15 0.140.140.140.140.140.140.140.14 0.130.130.130.130.130.130.130.13 0.120.120.120.120.120.120.120.12 0.11 0.036 0.32 0.27 0.24 0.22 0.20 0.180.180.180.180.180.180.18 0.160.160.160.160.160.160.16 0.150.150.150.150.150.150.15 0.140.140.140.140.140.140.14 0.130.130.130.130.130.130.13 0.120.120.120.120.120.120.12 0.11 0.10 0.034 0.31 0.26 0.24 0.21 0.190.190.190.190.190.190.190.19 0.170.170.170.170.170.170.170.17 0.160.160.160.160.160.160.160.16 0.150.150.150.150.150.150.150.15 0.140.140.140.140.140.140.140.14 0.130.130.130.130.130.130.130.13 0.120.120.120.120.120.120.120.12 0.11 0.10 0.032 0.30 0.26 0.23 0.20 0.180.180.180.180.180.180.18 0.170.170.170.170.170.170.17 0.150.150.150.150.150.150.15 0.140.140.140.140.140.140.14 0.130.130.130.130.130.130.13 0.120.120.120.120.120.120.12 0.11 0.10 0.09 0.030 0.29 0.25 0.22 0.190.190.190.190.190.190.190.19 0.180.180.180.180.180.180.180.18 0.160.160.160.160.160.160.160.16 0.150.150.150.150.150.150.150.15 0.140.140.140.140.140.140.140.14 0.130.130.130.130.130.130.130.13 0.120.120.120.120.120.120.120.12 0.11 0.10 0.09 0.028 0.27 0.24 0.21 0.190.190.190.190.190.190.19 0.170.170.170.170.170.170.17 0.150.150.150.150.150.150.15 0.140.140.140.140.140.140.14 0.130.130.130.130.130.130.13 0.120.120.120.120.120.120.12 0.11 0.100.10 0.100.10 0.09 0.026 0.26 0.23 0.20 0.180.180.180.180.180.180.18 0.160.160.160.160.160.160.16 0.150.150.150.150.150.150.15 0.140.140.140.140.140.140.14 0.120.120.120.120.120.120.12 0.120.120.120.120.120.120.12 0.11 0.10 0.090.09 0.080.08 0.024 0.25 0.22 0.190.190.190.190.190.190.19 0.170.170.170.170.170.170.17 0.160.160.160.160.160.160.16 0.140.140.140.140.140.140.14 0.130.130.130.130.130.130.13 0.120.120.120.120.120.120.12 0.11 0.100.10 0.100.10 0.090.09 0.080.08 0.022 0.24 0.20 0.180.180.180.180.180.18 0.160.160.160.160.160.16 0.140.140.140.140.140.14 0.130.130.130.130.130.13 0.120.120.120.120.120.12 0.11 0.100.10 0.100.10 0.090.09 0.080.08 0.07 0.020 0.22 0.190.190.190.190.19 0.170.170.170.170.17 0.150.150.150.150.15 0.130.130.130.130.13 0.120.120.120.120.12 0.11 0.100.10 0.100.10 0.090.09 0.080.08 0.070.07 0.070.07

Paroi contre terre Paroi contre locaux non chauffés Paroi contre l’extérieur

Dalle contre terre Dalle contre locaux non chauffés Dalle contre l’extérieur Produit isolant 1 : λ : W/mK Plafond ou toit

contre terre

Plafond/toit contre locaux non chauffés

Plafond/toit contre l’extérieur

Produit isolant 2 : λ : W/mK

Pour un élément de construction homogène : péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6.2)

de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6.2) W/(m2K) Justification des ponts thermiques oui non Valeur U limite (législation cantonale ou SIA 380/1)

Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction : W/(m2K)

14

CHOIX DU TYPE D’EXÉCUTION

CONSTRUCTION NEUVE ASSAINISSEMENT

BRIQUE TERRE CUITE

CONSTRUCTION NEUVE ASSAINISSEMENT

Épaisseur de l’élément sans isolation thermique

Isolation thermique homogène

Isolation thermique non-homogène

Épaisseur de l’isolant existant sur l’élément existant (λ 0.04)

Isolation thermique homogène supplémentaire

≤ 18 cm T6 T7 0 cm T7

18 ≤ 30 cm T5 T6 0 ≤ 1 cm T6

> 30 cm T4 T5 1 ≤ 2 cm T5

2 ≤ 4 cm T4

4 ≤ 6 cm T3

6 ≤ 10 cm T2

10 ≤ 14 cm T1

> 14 cm T1

Choisir le tableau correspondant (type et épaisseur de l’isolation thermique)

Choisir le tableau correspondant (épaisseur de l’isolant sur l’élément existant et type de nouvelle isolation thermique)

CHOIX DU MODE DE CONSTRUCTION

i e

i

e i e

i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e

e

i i e

i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e i e

e i Béton

Brique ciment Brique silico-calcaire

Brique terre cuite

Béton cellulaire

MARCHE À SUIVRE

PREMIÈRE ÉTAPE

Choix du mode de construction

DEUXIÈME ÉTAPE Choix du type d’exécution

TROISIÈME ÉTAPE

Choix du facteur λ et de l’épaisseur d’isolant

(12)
(13)

DÉTERMINATION DE LA VALEUR U D’UN ÉLÉMENT DE CONSTRUCTION

CHOIX DU MODE DE CONSTRUCTION

Illustrations schématiques valables pour mur, toit et sol

i e

i

e

i e

e

i

i e

e i

i e

e

i

Béton Brique ciment Brique silico­calcaire

Brique terre cuite

Béton cellulaire

Construction en bois (éléments ou construction massive) Construction en métal

(14)

14

CHOIX DU TYPE D’EXÉCUTION

Illustrations schématiques valables pour mur, toit et sol

BÉTON, AGGLOMÉRÉ PLEIN EN CIMENT, BRIQUE SILICO-CALCAIRE

CONSTRUCTION NEUVE ASSAINISSEMENT

Épaisseur de l’élément sans isolation

thermique

Isolation thermique homogène

Isolation thermique non­homogène

Épaisseur de l’isolant existant sur l’élément existant (λ 0 .04)

Isolation thermique homogène supplémentaire

Isolation thermique non­homogène supplémentaire

≤ 30 cm T7 T8 0 cm T7 T8

> 30 cm T6 T7 0 ≤ 1 cm T6 T7

1 ≤ 2 cm T5 T6

2 ≤ 4 cm T4 T5

4 ≤ 6 cm T3 T4

6 ≤ 10 cm T2 T3

10 ≤ 14 cm T1 T2

> 14 cm T1 T1

Choisir le tableau correspondant

(type et épaisseur de l’isolation thermique)

Choisir le tableau correspondant (épaisseur de l’isolant sur l’élément existant et type de nouvelle isolation thermique)

BRIQUE TERRE CUITE

CONSTRUCTION NEUVE ASSAINISSEMENT

Épaisseur de l’élément sans isolation

thermique

Isolation thermique homogène

Isolation thermique non­homogène

Épaisseur de l’isolant existant sur l’élément existant (λ 0 .04)

Isolation thermique homogène supplémentaire

Isolation thermique non­homogène supplémentaire

≤ 18 cm T6 T7 0 cm T7 T8

18 ≤ 30 cm T5 T6 0 ≤ 1 cm T6 T7

> 30 cm T4 T5 1 ≤ 2 cm T5 T6

2 ≤ 4 cm T4 T5

4 ≤ 6 cm T3 T4

6 ≤ 10 cm T2 T3

10 ≤ 14 cm T1 T2

> 14 cm T1 T1

Choisir le tableau correspondant

(type et épaisseur de l’isolation thermique)

Choisir le tableau correspondant (épaisseur de l’isolant sur l’élément existant et type de nouvelle isolation thermique)

Élément neuf Élément existant

Nouvelle couche d’isolation Couche d’isolation existante

Épaisseur du matériau e =extérieur

i =intérieur

(15)

CHOIX DU TYPE D’EXÉCUTION

Illustrations schématiques valables pour mur, toit et sol BÉTON CELLULAIRE

CONSTRUCTION NEUVE ASSAINISSEMENT

Épaisseur de l’élément sans isolation

thermique

Isolation thermique homogène

Isolation thermique non­homogène

Épaisseur de l’isolant existant sur l’élément existant (λ 0 .04)

Isolation thermique homogène supplémentaire

Isolation thermique non­homogène supplémentaire

≤ 18 cm T4 T5 0 cm T7 T8

18 ≤ 25 cm T3 T4 0 ≤ 1 cm T6 T7

25 ≤ 35 cm T2 T3 1 ≤ 2 cm T5 T6

> 35 cm T1 T2 2 ≤ 4 cm T4 T5

4 ≤ 6 cm T3 T4

6 ≤ 10 cm T2 T3

10 ≤ 14 cm T1 T2

> 14 cm T1 T1

Choisir le tableau correspondant

(type et épaisseur de l’isolation thermique)

Choisir le tableau correspondant (épaisseur de l’isolant sur l’élément existant et type de nouvelle isolation thermique)

CONSTRUCTION EN BOIS (OSSATURE, ÉLÉMENTS OU CONSTRUCTION MASSIVE), CONSTRUCTION EN MÉTAL

CONSTRUCTION NEUVE ASSAINISSEMENT

Épaisseur de l’élément sans isolation

thermique

Isolation thermique homogène

Isolation thermique non­homogène

Épaisseur de l’isolant existant sur l’élément existant (λ 0 .04)

Isolation thermique homogène supplémentaire

Isolation thermique non­homogène supplémentaire

Construction en bois T7 T8 0 cm T7 T8

Construction en métal T7 T8 0 ≤ 1 cm T6 T7

≤ 4 cm T7 T8 1 ≤ 2 cm T5 T6

4 ≤ 8 cm T6 T7 2 ≤ 4 cm T4 T5

8 ≤ 12 cm T5 T6 4 ≤ 6 cm T3 T4

> 12 cm T4 T5 6 ≤ 10 cm T2 T3

10 ≤ 14 cm T1 T2

> 14 cm T1 T1

Choisir le tableau correspondant Choisir le tableau correspondant (épaisseur de l’isolant sur l’élément Élément neuf

Élément existant

Nouvelle couche d’isolation Couche d’isolation existante

Épaisseur du matériau e =extérieur

i =intérieur

(16)

16

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs ––> 35 cm, isolation thermique homogène– >14cm, avec nvelle isolation therm . non­homogène >14cm, avec nvelle isolation therm . homogène 10≤14cm, avec nvelle isolation therm . homogène

TA B LE A U T 1 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0 .0460 .190 .180 .170 .160 .150 .140 .130 .130 .120 .110 .110 .100 .10 0 .0440 .190 .170 .160 .150 .140 .140 .130 .120 .120 .110 .110 .100 .09 0 .0420 .180 .170 .160 .150 .140 .130 .130 .120 .110 .110 .100 .100 .09 0 .0400 .180 .170 .160 .140 .140 .130 .120 .120 .110 .100 .100 .090 .09 0 .0380 .170 .160 .150 .140 .130 .120 .120 .110 .110 .100 .100 .090 .08 0 .0360 .170 .160 .150 .140 .130 .120 .110 .110 .100 .100 .090 .090 .08 0 .0340 .170 .150 .140 .130 .130 .120 .110 .100 .100 .090 .090 .080 .08 0 .0320 .160 .150 .140 .130 .120 .110 .110 .100 .100 .090 .090 .080 .08 0 .0300 .160 .150 .140 .130 .120 .110 .110 .100 .090 .090 .080 .080 .07 0 .0280 .160 .140 .130 .120 .120 .110 .100 .100 .090 .090 .080 .080 .07 0 .0260 .150 .140 .130 .120 .110 .100 .100 .090 .090 .080 .080 .070 .07 0 .0240 .150 .140 .130 .120 .110 .100 .100 .090 .090 .080 .080 .070 .07 0 .0220 .140 .130 .120 .110 .100 .100 .090 .080 .080 .080 .070 .070 .06 0 .0200 .140 .120 .120 .110 .100 .090 .090 .080 .080 .070 .070 .060 .06 Paroi contre terre Paroi contre locaux non chauffés Paroi contre locaux non chauffés Paroi contre l’extérieur Dalle contre terre Dalle contre locaux non chauffés Dalle contre locaux non chauffés Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6 .2) W/(m2K) Justification des ponts thermiques oui oui non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(17)

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs –– > 35 cm, > 35 cm, isolation therm . non­homogène 25 ≤ 35cm, isolation therm . homogène–10≤14cm,avec nvelle isolation therm . non­homogène 6≤10cm, avec nvelle isolation therm . homogène

TA B LE A U T 2 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0 .0460 .220 .200 .190 .170 .160 .150 .150 .140 .130 .120 .120 .110 .10 0 .0440 .210 .200 .180 .170 .160 .150 .140 .130 .130 .120 .110 .110 .10 0 .0420 .210 .190 .180 .170 .160 .150 .140 .130 .120 .120 .110 .100 .10 0 .0400 .200 .190 .170 .160 .150 .140 .130 .130 .120 .110 .110 .100 .09 0 .0380 .200 .180 .170 .160 .150 .140 .130 .120 .110 .110 .100 .100 .09 0 .0360 .190 .180 .160 .150 .140 .130 .120 .120 .110 .100 .100 .090 .09 0 .0340 .190 .170 .160 .150 .140 .130 .120 .110 .110 .100 .100 .090 .08 0 .0320 .190 .170 .160 .140 .130 .120 .120 .110 .100 .100 .090 .090 .08 0 .0300 .180 .170 .150 .140 .130 .120 .110 .110 .100 .100 .090 .080 .08 0 .0280 .180 .160 .150 .140 .130 .120 .110 .100 .100 .090 .090 .080 .08 0 .0260 .170 .160 .140 .130 .120 .110 .110 .100 .090 .090 .080 .080 .07 0 .0240 .170 .150 .140 .130 .120 .110 .100 .100 .090 .090 .080 .070 .07 0 .0220 .160 .140 .130 .120 .110 .100 .100 .090 .090 .080 .080 .070 .06 0 .0200 .150 .140 .130 .110 .110 .100 .090 .080 .080 .080 .070 .070 .06 Paroi contre terre Paroi contre locaux non chauffés Paroi contre locaux non chauffés Paroi contre l’extérieur Dalle contre terre Dalle contre locaux non chauffés Dalle contre locaux non chauffés Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6 .2) W/(m2K) Justification des ponts thermiques oui oui non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(18)

18

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs –– 25 25≤35 cm, isolation therm . non­homogène 18 ≤ 25 cm, isolation therm . homogène– 6 6 6 6≤10cm, avec nvelle isolation therm . non­homogène 4 4≤6cm, avec nvelle isolation therm . homogène

TA B LE A U T 3 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0 .0460 .250 .230 .210 .200 .180 .170 .160 .150 .140 .140 .130 .120 .11 0 .0440 .250 .230 .210 .190 .180 .170 .160 .150 .140 .130 .120 .120 .11 0 .0420 .240 .220 .200 .190 .170 .160 .150 .140 .130 .130 .120 .110 .10 0 .0400 .240 .210 .200 .180 .170 .150 .150 .140 .130 .120 .110 .110 .10 0 .0380 .230 .210 .190 .170 .160 .150 .140 .130 .120 .120 .110 .100 .10 0 .0360 .220 .200 .180 .170 .160 .140 .130 .130 .120 .110 .100 .100 .09 0 .0340 .220 .190 .180 .160 .150 .140 .130 .120 .120 .110 .100 .090 .09 0 .0320 .210 .190 .170 .160 .150 .140 .130 .120 .110 .100 .100 .090 .08 0 .0300 .210 .180 .170 .150 .140 .130 .120 .110 .110 .100 .090 .090 .08 0 .0280 .200 .180 .160 .150 .140 .130 .120 .110 .100 .100 .090 .080 .08 0 .0260 .190 .170 .160 .140 .130 .120 .110 .110 .100 .090 .090 .080 .08 0 .0240 .190 .170 .150 .140 .130 .120 .110 .100 .100 .090 .080 .080 .07 0 .0220 .180 .160 .150 .130 .120 .110 .100 .100 .090 .080 .080 .070 .07 0 .0200 .170 .150 .140 .120 .110 .100 .100 .090 .080 .080 .070 .070 .06 Paroi contre terre Paroi contre locaux non chauffés Paroi contre l’extérieur Paroi contre l’extérieur Dalle contre terre Dalle contre locaux non chauffés Dalle contre l’extérieur Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6 .2) W/(m2K) Justification des ponts thermiques oui oui non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(19)

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs –>30 cm, isolation therm . homogène 18 18≤25 cm, isolation therm . non­homogène ≤18 cm, isolation therm . homogène>12 cm, isolation therm . homogène 4 ≤ 6 cm, avec nvelle isolation therm 4 ≤ 6 cm, avec nvelle isolation therm . non­homogène 2 ≤ 4 cm, avec nvelle isolation therm 2 ≤ 4 cm, avec nvelle isolation therm . homogène

TA B LE A U T 4 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0 .0460 .300 .270 .240 .220 .210 .190 .180 .170 .160 .150 .140 .130 .12 0 .0440 .290 .260 .240 .210 .200 .180 .170 .160 .150 .140 .130 .120 .11 0 .0420 .280 .250 .230 .210 .190 .180 .160 .150 .140 .140 .130 .120 .11 0 .0400 .270 .240 .220 .200 .180 .170 .160 .150 .140 .130 .120 .110 .10 0 .0380 .260 .230 .210 .190 .180 .160 .150 .140 .130 .120 .120 .110 .10 0 .0360 .250 .220 .200 .180 .170 .160 .150 .130 .130 .120 .110 .100 .10 0 .0340 .250 .220 .200 .180 .160 .150 .140 .130 .120 .120 .110 .100 .09 0 .0320 .240 .210 .190 .170 .160 .150 .140 .130 .120 .110 .100 .100 .09 0 .0300 .230 .210 .190 .170 .150 .140 .130 .120 .110 .110 .100 .090 .09 0 .0280 .230 .200 .180 .160 .150 .140 .130 .120 .110 .100 .100 .090 .08 0 .0260 .220 .190 .170 .160 .140 .130 .120 .110 .110 .100 .090 .090 .08 0 .0240 .210 .190 .170 .150 .140 .130 .120 .110 .100 .100 .090 .080 .08 0 .0220 .200 .170 .160 .140 .130 .120 .110 .100 .100 .090 .080 .080 .07 0 .0200 .190 .160 .150 .130 .120 .110 .100 .090 .090 .080 .080 .070 .06 Paroi contre terre Paroi contre locaux non chauffés Paroi contre l’extérieur Paroi contre l’extérieur Dalle contre terre Dalle contre locaux non chauffés Dalle contre l’extérieur Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6 .2) W/(m2K) Justification des ponts thermiques oui oui non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(20)

20

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs – > >30cm, isolation therm. non-homogène 18 18≤30 cm, isolation therm. homogène≤ 18 cm, isolation therm. non-homogène>12cm, isolation therm. non-homogène 8≤12cm, isolation therm. homogène 2≤4cm,avec nvelle isolation therm. non-homogène 1≤2cm, avec nvelle isolation therm. homogène

TA B LE A U T 5 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0.0460.340.300.270.240.230.210.190.180.170.160.150.140.12 0.0440.330.290.260.240.220.200.190.170.160.150.140.130.12 0.0420.320.280.250.230.210.190.180.160.150.140.130.120.11 0.0400.310.270.250.220.200.180.170.160.150.140.130.120.11 0.0380.300.260.240.210.190.180.160.150.140.130.120.110.10 0.0360.280.250.230.200.180.170.160.140.130.130.120.110.10 0.0340.280.240.220.190.180.160.150.140.130.120.110.100.10 0.0320.270.230.210.190.170.160.150.130.130.120.110.100.09 0.0300.260.230.200.180.170.150.140.130.120.110.100.100.09 0.0280.250.220.200.170.160.140.130.120.120.110.100.090.08 0.0260.240.210.190.170.150.140.130.120.110.100.100.090.08 0.0240.230.200.180.160.150.130.120.110.110.100.090.080.08 0.0220.220.190.170.150.140.120.120.110.100.090.090.080.07 0.0200.200.180.160.140.130.120.110.100.090.090.080.070.07 Paroi contre terre Paroi contre terre Paroi contre locaux non chauffés Paroi contre l’extérieur Dalle contre terre Dalle contre terre Dalle contre locaux non chauffés Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6.2) W/(m2K) Justification des ponts thermiques oui non non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(21)

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs > 30 cm, isolation therm. homogène 18 18≤30 cm, isolation therm. non-homogène ≤ 18 cm, isolation therm. homogène– 8≤12cm, isolation therm. non-homogène 8≤12cm, isolation therm. non-homogène 4≤8 cm, isolation therm. homogène 1 1 1 1≤2cm, avec nvelle isolation therm. non-homogène 0 0≤1cm, avec nvelle isolation therm. homogène

TA B LE A U T 6 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0.0460.390.340.300.270.250.220.210.190.180.170.150.140.13 0.0440.370.320.290.260.240.210.200.180.170.160.150.140.12 0.0420.360.310.280.250.230.200.190.170.160.150.140.130.12 0.0400.340.300.270.240.220.200.180.170.160.150.130.120.11 0.0380.330.290.260.230.210.190.170.160.150.140.130.120.11 0.0360.320.270.240.220.200.180.160.150.140.130.120.110.10 0.0340.310.260.240.210.190.170.160.150.140.130.120.110.10 0.0320.300.260.230.200.180.170.150.140.130.120.110.100.09 0.0300.290.250.220.190.180.160.150.140.130.120.110.100.09 0.0280.270.240.210.190.170.150.140.130.120.110.100.100.09 0.0260.260.230.200.180.160.150.140.120.120.110.100.090.08 0.0240.250.220.190.170.160.140.130.120.110.100.100.090.08 0.0220.240.200.180.160.140.130.120.110.100.100.090.080.07 0.0200.220.190.170.150.130.120.110.100.100.090.080.070.07 Paroi contre terre Paroi contre locaux non chauffés Paroi contre locaux non chauffés Paroi contre l’extérieur Dalle contre terre Dalle contre locaux non chauffés Dalle contre locaux non chauffés Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6.2) W/(m2K) Justification des ponts thermiques oui oui non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(22)

22

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs >30 cm, isolation therm . non­homogène ≤ ≤30cm, isolation therm . homogène

≤18 cm, isolation therm . non­homogène –4 ≤ 8 cm, isolation therm . non­homogène ≤ 4 cm, isolation therm ≤ 4 cm, isolation therm . homogène construction en métal ou bois, isolation therm construction en métal ou bois, isolation therm . homogène 0≤1 cm, avec nvelle isolation therm . non­homogène 0 cm, avec nvelle isolation therm 0 cm, avec nvelle isolation therm 0 cm, avec nvelle isolation therm 0 cm, avec nvelle isolation therm . homogène

TA B LE A U T 7 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0 .0460 .440 .370 .330 .290 .260 .240 .220 .200 .190 .170 .160 .150 .13 0 .0440 .420 .360 .320 .280 .250 .230 .210 .190 .180 .170 .150 .140 .13 0 .0420 .400 .340 .300 .270 .240 .220 .200 .180 .170 .160 .150 .130 .12 0 .0400 .380 .330 .290 .250 .230 .210 .190 .180 .160 .150 .140 .130 .12 0 .0380 .370 .310 .280 .240 .220 .200 .180 .170 .160 .140 .130 .120 .11 0 .0360 .350 .300 .260 .230 .210 .190 .170 .160 .150 .140 .130 .120 .10 0 .0340 .340 .290 .250 .220 .200 .180 .170 .150 .140 .130 .120 .110 .10 0 .0320 .320 .280 .240 .210 .190 .170 .160 .150 .140 .130 .120 .110 .10 0 .0300 .310 .270 .240 .210 .190 .170 .150 .140 .130 .120 .110 .100 .09 0 .0280 .300 .250 .230 .200 .180 .160 .150 .130 .130 .120 .110 .100 .09 0 .0260 .290 .240 .220 .190 .170 .150 .140 .130 .120 .110 .100 .090 .09 0 .0240 .270 .230 .210 .180 .160 .150 .130 .120 .110 .110 .100 .090 .08 0 .0220 .250 .220 .190 .170 .150 .140 .120 .110 .110 .100 .090 .080 .08 0 .0200 .240 .200 .180 .150 .140 .120 .110 .100 .100 .090 .080 .080 .07 Paroi contre terre Paroi contre locaux non chauffés Paroi contre locaux non chauffés Paroi contre l’extérieur Dalle contre terre Dalle contre locaux non chauffés Dalle contre locaux non chauffés Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6 .2) W/(m2K) Justification des ponts thermiques oui oui non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(23)

Béton, brique ciment Brique silico-calcaireBrique terre cuiteBéton cellulaireConstruction en bois Construction en métalAssainissements tous les types de murs ≤ 30 cm, isolation therm . non­homogène –– ≤ 4 cm, isolation therm ≤ 4 cm, isolation therm . non­homogène construction en métal ou bois, isolation therm . non­homogène 0 cm, avec nvelle isolation therm . non­homogène

TA B LE A U T 8 Va le ur s U W/ (m

2

K )

ÉLÉMENT DE CONSTRUCTION: ÉP. ISOLANT (M)d = 0.10 d = 0.12 d = 0.14 d = 0.16 d = 0.18 d = 0.20d = 0.22d = 0.24d = 0.26 d = 0.28 d = 0.30 d = 0.32 d = 0.34

Con duc tivi té th erm λ ique

0 .0460 .460 .390 .350 .300 .270 .250 .230 .210 .190 .180 .160 .150 .14 0 .0440 .440 .380 .330 .290 .260 .240 .220 .200 .180 .170 .160 .140 .13 0 .0420 .420 .360 .320 .280 .250 .220 .210 .190 .180 .160 .150 .140 .12 0 .0400 .410 .340 .300 .260 .240 .210 .200 .180 .170 .160 .140 .130 .12 0 .0380 .390 .330 .290 .250 .230 .200 .190 .170 .160 .150 .140 .120 .11 0 .0360 .370 .310 .270 .240 .220 .190 .180 .160 .150 .140 .130 .120 .11 0 .0340 .350 .300 .260 .230 .210 .190 .170 .160 .150 .130 .120 .110 .10 0 .0320 .340 .290 .250 .220 .200 .180 .160 .150 .140 .130 .120 .110 .10 0 .0300 .330 .280 .240 .210 .190 .170 .160 .140 .130 .120 .110 .100 .09 0 .0280 .310 .260 .230 .200 .180 .160 .150 .140 .130 .120 .110 .100 .09 0 .0260 .300 .250 .220 .190 .170 .160 .140 .130 .120 .110 .100 .100 .09 0 .0240 .290 .240 .210 .180 .170 .150 .140 .130 .120 .110 .100 .090 .08 0 .0220 .260 .220 .200 .170 .150 .140 .130 .120 .110 .100 .090 .080 .08 0 .0200 .240 .210 .180 .160 .140 .130 .120 .110 .100 .090 .080 .080 .07 Paroi contre terre Paroi contre locaux non chauffés Paroi contre locaux non chauffés Paroi contre l’extérieur Dalle contre terre Dalle contre locaux non chauffés Dalle contre locaux non chauffés Dalle contre l’extérieurProduit isolant 1: λ : W/mK Plafond ou toit contre terrePlafond/toit contre locaux non chauffés Plafond/toit contre l’extérieurProduit isolant 2: λ : W/mK Pour un élément de construction homogène: péjoration de la valeur U pour éléments de fixation de façade ventilée (catalogue de ponts thermiques, OFEN, 2002, chapitre 6 .2) W/(m2K) Justification des ponts thermiques oui non Valeur U limite (législation cantonale ou SIA 380/1) W/(m2K) Valeur U de l’élément de construction: W/(m2K)

(24)

SuisseEnergie, Office fédéral de l’énergie OFEN

Mühlestrasse 4, CH­3063 Ittigen . Adresse postale : CH­3003 Berne Infoline 0848 444 444, www .suisseenergie .ch/conseil

energieschweiz@bfe .admin .ch, www .suisseenergie .ch Distribution : www .publicationsfederales .admin .ch

Numéro d’article 805 .150 .F 06 .2

016300860380695

www .aee .ch (D­F) AEE Agence des énergies renouvelables et de l’efficacité énergétique www .catalogueconstruction .ch Base gratuite du catalogue d’éléments de construction

www .cecb .ch Certificat énergétique cantonal des bâtiments

www .ecospeed .ch Votre bilan énergétique personnel

www .edifices­suisse .ch Enveloppe des édifices en Suisse

www .endk .ch Conférence des directeurs cantonaux de l’énergie

www .etiquetteenergie .ch Étiquette Énergie pour appareils électroménagers, l’éclairage et les voitures www .energie­environnement .ch (D­F) Site des cantons pour des infos sur l’utilisation rationnelle

de l’énergie et l’environnement

www .energybox .ch Jugez votre consommation d’électricité

www .garantie­de­performance .ch Garantie de performance pour les installations techniques domestiques

www .minergie .ch Le label énergétique pour les bâtiments

www .suisseenergie .ch Office fédéral de l’énergie OFEN www .suisseenergie .ch/checkchauffage Check­bâtiment­chauffage

www .topten .ch Les meilleurs appareils ménagers et de bureau

JE VEUX EN SAVOIR PLUS

IMPRESSUM

AUTEURS

Kurt Marti, Ingenieurbüro für Energie und Umwelt, CH­3054 Schüpfen Markus Di Paolantonio, Holliger Consult GmbH, Dorfstrasse 4, CH­3272 Epsach TRADUCTION

ACTA Conseils Sàrl

CRÉDIT PHOTOGRAPHIQUE

© miket / MHjerpe / Wilm Ihlenfeld / Brebca / Ingo Bartussek / auremar / Dmitriy Kalinin / gilles lougassi / tuja66 / nfrPictures / Kaarsten – Fotolia .com

Referenzen

ÄHNLICHE DOKUMENTE

TV5MONDE et Arlette Alziary, consultante CIEP/OIF Entre les murs : L’autoportrait de Carl 1/12.. ENTRE LES MURS : L’autoportrait

Mesures permettant de supprimer ou de réduire les dégâts, classées selon les principes de réfection utilisés pour la pro- tection contre la corrosion : R (repassivation), W

Associés au bois de façon distincte dans la construction, la brique est utilisée pour les murs de façade des deux premiers étages et le béton pour les murs porteurs en sous-sol, les

[r]

Toutefois, im- médiatement après la récolte, c'est-à- dire après le passage de la machine (trois roues ), l' engrais vert n'était prati- quement plus visible. Le ray-grass

S’il existait une relation évidente entre le fléchissement sous une charge relative- ment faible d’une part et la portance de l’élément caillebotis en béton d’autre part,

Ce qui est le plus remarquable, c'est la teneur énergétique beaucoup plus élevée du lait de brebis par rapport à ceux de vache et de chèvre.. Cela est surtout dû à sa forte

De 1990 à 2005, les données météorologiques et les épidémies de la maladie ont été caractérisées et analysées et ont démontré l’im- portance du mildiou en Suisse: douze