This board is designed for use with IBM®- compatible personal computers. It can be used only to connect your computer to an EPSON color image scanner.

Installation Guide

1. Unpack the interface board

c

Caution:Do not touch the parts on the board or the board connector.

2. Change Jumper J2 to IRQ7

Change the setting of jumper J2 on the interface board to IRQ7. This is the setting for compatibility with most PCs.

3. Install the board in the PC

Install the board in a free 16 bit option slot.

See overleaf if you need detailed instructions.

w

Warning:Never remove the cover of the computer while it is plugged into a power source.

Turn the computer off and unplug it from the AC (power) outlet.

4. Connect the scanner

See the User’s Guide supplied with the scanner.

5. Install the scanner software

See the scanner driver software disks or CDs and instructions supplied with the Epson scanner system (except for some scanner only systems).

Jumper Settings

The interface board contains 3 jumpers labelled J1, J2 and J3.

To change a jumper setting, lift the jumper of the pins and reinstall it over the pins to make the setting that you want.

J1

LPT2: Use this setting for most PCs.

?

LPT1: Because the majority of PCs already have a built in parallel interface port for a printer using LPT1, you should not need to set this jumper to LPT1.

J2

IRQ7:Use this setting for most PCs. Set this jumper to IRQ7 before installing the interface board in the PC.

?

IRQ5:If other options in the PC are already using IRQ7, set this jumper to IRQ5.

Note: Some sound boards use IRQ5.

J3

B: This jumper must always be set to B.

Interface Cable

Connect the interface board to the scanner using a shielded parallel interface cable that has a DB25 (D-sub 25 pin) male connector on one end and a Centronics®-type 36-pin connector on the other. Epson scanner systems are supplied with a suitable cable (except for scanner only systems).

Bi-directional Parallel Interface Board B80818 @ @

Bi-directional Parallel

Interface Board B80818@

EPSON

®

4005242-EUL02 C01-01

(2)

Use these instructions when referred to in step 3 of the installation guide overleaf.

These are general instructions only. You may need to see the computer’s manual for the correct option board installation procedure.

Note:You will need appropriate screwdrivers.

1. Turn the computer off and unplug it from the AC (power) outlet.

w

Warning:Never remove the cover of the computer while it is plugged into a power source.

2. Disconnect the keyboard, monitor and all the cables and peripherals from the computer, and then move it to a place that will allow sufficient room for installation.

Note:You may need to unscrew some cables with a screwdriver.

3. Remove the cover retaining screws and keep them in a safe place while you work on the computer.

4. Remove the cover.

5. Choose a 16-bit option slot in which to install the board, and remove the screw and slot cover.

6. Insert the card gently into the slot in the correct direction.

c

Cautions:Set the jumpers on the interface board correctly before inserting it into the PC.

See the Installation Guide and Jumper Settings sections overleaf.

Do not touch the parts on the board or the board connector.

If the board does not seem to fit, do not try to force it. Check the alignment of the connectors and then reinsert the board. Be sure that it is firmly seated in the slot.

7. Secure the board with the screw you removed from the slot cover.

8. Replace the top cover of the computer and secure it with the retaining screws.

9. Reconnect the keyboard, monitor, and peripherals to the computer.

10. Turn the computer on and check to see that it operates correctly.

General instructions for installing the interface board in a PC

Referenzen

ÄHNLICHE DOKUMENTE

(3 ), the apparent activation volumes of these samples increase moderately up to about 60 b 3 with testing temperature. Sig- nificantly larger values of almost 400 b 3 are measured

The prototype model developed at the BFH-CSEM Energy Storage Research Centre in Biel consists of eleven lithium-ion battery cells and has a storage capacity of 6.5 kWh... the

This study examined the hypothesis that participants will be more motivated in a free spelling paradigm than in a copy spelling paradigm, and that their accuracy would be

Published by Graz University of Technology Publishing House Article ID 101-3.. In Experiment 1, no differences were observed in motivation as measured by the OLMQ, or in fatigue

Connect the display interface ribbon cable (contains a 2 6—pin female connector on one end and a 25—pin male connector on the other end) between ND600 Terminal and the DMB

After shortly classifying the various kinds of attacks we accomplish malicious code attacks on real World Wide Web transaction systems.. In doing so we find that it is really easy

Candidates with transcription factor or growth factor activity were identified within the tran- scripts that were enriched in the enthesis compared to tendon.. MDFI MyoD

2 Haptic assistance systems in driving 9 3 Vibrotactile displays in the take-over process 11 4 Design of a vibrotactile seat 13 5 Comparing visual, auditory, and vibrotactile