• Keine Ergebnisse gefunden

I STC837 REQUESTED DEVICE(S) NOT AVAILABLE

Im Dokument For Online Subsystem (Seite 119-123)

There were no devices selected. The devices that were requested for testing by the operator or by control card input did not match any of the configured devices.

I

STC838 TEST ttt NOT SELECTED - reason

Test ttt was not selected for execution. This message is issued for all tests which are contained in the test range specified but which will not be executed. Reasons for not being selected are:

1. MUST BE REQUESTED - The test is only executed if spe-cifically requested. It will not be executed if a

test range is specified.

2. NO WRITE SPACE - No space is allocated for write testing.

3. NOT STAND-ALONE - The test can only be executed with STCPOST executing under the STCPOST Stand-Alone

Executive (SAE) on a real CPU.

STC8S0 UNSUPPORTED OlT MACRO CAll AT aa .. aa, R1=bb .. bb

The OlT Transient Manager was called from address aa .. aa but the type of call is either unknown, invalid or unsup-ported. The contents of register 1 at the time of the call was bb .. bb. This message indicates the presence of an

internal error in a diagnostic test and should be reported to STC FE Software Support.

STC851 OlT CAll AT aa .. aa, R1=bb .. bb, ID=cc

The OlT Transient Manager was called from address aa .. aa.

The contents of register 1 at the time of the call was bb .. bb. The 10 of the OlT making the call is cc. This mes-sage is only printed if the TMTRACE parameter was speci-fied.

STC852 OlT lOADED AT aa .. aa

An OlT has been loaded starting at address aa .. aa. This message is only printed if the TMTRACE parameter was

spec-ified.

STCPOST Messages STC853

STC853 TECS BEFORE I/O

--A dump of the TECS prior to the start of the I/O operation follows. This message is only printed if the TMTRACE

parameter was specified.

STC854 TECB AFTER I/O

--A dump of the TECS after the I/O operation is completed follows. This message is only printed if the TMTRACE parameter was specified.

STC855 aa .. aa RTN bb BYPASSED -- MANUAL INTV REQUIRED

Routine bb of test aa .. aa requires manual intervention but the MI parameter or option was not specified. The routine will be bypassed.

I

STC860 tttttttt

rr - mmm ... mrnm

Diagnostic test tttttttt routine rr has issued message mmm ... mmm. This message mayor may not be a reply mes-sage. If it is a reply message, the diagnostic test will not continue until a reply is made at the operator's con-sole.

STC861 OPERATOR REPLY -

rrr ... rrr

The operator has replied to a reply message (see message STC860). rrr ... rrr is the reply text.

STC900 CUTRACE -- DEVICE ADDRESS a, VOL SER v

The CUTRACE function will be executed on the device at address a with volume serial number v mounted.

STC901 PARAMETER ERROR (xx .. xx)

The parameter xx .. xx is either coded incorrectly or is invalid for the CUT RACE function.

STC902 TEST DEVICE DO FAILED TO OPEN

An open for the test device failed. Verify that the test device DO card for the current setting of the OPTION

func-tion DDNAME parameter is coded correctly.

STC903 TEST DEVICE IS NOT A DEVICE WHICH ATTACHES TO A 8000, 4000 OR 8880 CONTROL UNIT

The test device DD card defines a device which is not a 2305, 3330-1, 3330-11 or 3350 type device. Verify that the test device DD card for the current setting of the OPTION function DDNAME parameter is coded correctly.

STC904 CU TYPE 4000 REQUIRES 2305-2 TEST DEVICE TYPE

The test device DD card defines a device which is 2305-2 type device but the CUTYPE parameter does not specify a 4000 CU. Verify that the test device DD card for the cur-rent setting of the OPTION function DD~AME parameter is coded correctly.

STC905 CUTYPE PARAMETER IS REQUIRED

The CUTYPE parameter was not specified on the function control card. This parameter is required for the CUT RACE

function.

STC921 LESS THAN 1024 BYTES TRANSFERRED

A 'Read Diagnostic Status l' CCW has returned less than 1024 bytes of data. A valid control unit trace contains either 1024 or 2816 bytes of data.

STC922 MORE THAN 1024 BUT LESS THAN 2816 BYTES TRANSFERRED

A 'Read Diagnostic Status l' CCW has returned an invalid number of data bytes. A valid control unit trace contains either 1024 or 2816 bytes.

ST.C923 CONTROL UNIT TRACE DUMP WAS NOT SUCCESSFUL

An error occurred attempting to read the control unit trace data. The function terminates.

STC931 I/O ERROR ...

This is an STCPOST standard error message. An error occurred attempting to read the control unit trace data

from an ISC or an 8000-2.

xX .. xx

STCPOST Messages STC940

STC940 8880 CONTROL UNITS ARE NOT SUPPORTED

The CUTYPE parameter specified 8880 but these control units are not yet supported.

STC950 I/O ERROR 0 0 0

This is an STCPOST standard error message. An error occurred attempting to read the diagnostic loader from a 4000 CU.

STC951 I/O ERROR 0 0 0

This is an STCPOST standard error message. An error occurred attempting to read the control unit trace data

from a 4000 CU.

STC952 DIAGNOSTIC WRITE/READ STATUS 1 FAILED

An attempt to read a diagnostic routine from the floppy disk failed. The routine is used to read the sectors

con-taining trace data. The function terminates.

STC953 CONTROL UNIT TRACE DUMP WAS NOT SUCCESSFUL

An attempt to read a portion of the trace buffer failed.

The function terminates.

STC954 TRACE INLINE NOT RUN OR INLINE ERROR

The trace data read from the 4000 CU indicates that the control unit trace was either not active, was stopped or

the inline which activates the trace had an error.

STC955 TRACE PARMS NOT ENTERED - NO TRACE DATA STORED

The trace was activated, but the engineer who started the trace did not specify whether to do a pre- or a

post-trigger. The function terminates. The engineer should restart the trace function and repeat the testing which was to trigger the storage of trace data.

STC956 PRE-TRIGGER ENABLED, TRACE DATA NOT STORED

The trace function was enabled for a pre-trigger which never occurred. The function terminates. The engineer should consider a different trigger condition.

Im Dokument For Online Subsystem (Seite 119-123)