B.7.2. Data Transfer Errors
10.3. Parameter Usts
10.3.2.3. Implemented Operating Definitions
c
('
10.3.2.3. Implemented Operating Definitions
BYTE BIT 7 6 5 4 3 2 1
o
00 Qualifier
I
Peripheral Device Type01 Page Code
=
81h02 RESERVED 03 Page Length
=
02h04 R
05 Simp
Qualffier
Peripheral Device Type
Page Code
Page Length
Current Operating DefinHion
Simp
Default Operating DefinHlon
Current Operating Definition
=
03hDefauh Operating Definition = 03h
Table: Implemented Operating Definitions Page
This field will nonnally be set to zero. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to 3.
This field is nonnally set to 1. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to lFh.
This field will be set to the value of the Page Code field in the Command Descriptor Block.
This field will specify the length in bytes of the parameters that follow the Page Length field.
This field will be set to 03h to indicate that the Drive implements the SCSI-2 X3.131-199X Operating Definition.
This bit will be set to zero.
This field will be set to 03h to indicate that the Drive implements the SCSI-2 X3.131-199X Operating Definition.
70-9 SCSl-2 Functional Specifications
BYTE
10.3.2.4. ASCII Implemented Operating Definition
BIT 7 6 5 4 3 2 1
o
Qualifier
I
Peripheral Devk:e TypePage Code
=
82h RESERVED Page Length=
13hASCII Operating Definition "S"
Table: ASCII Implemented Operating Definition Page
This field will normally be set to zero. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to 3.
10-10 SCSI-2 Functional Specifications
(:
Page Code
Page Length
ASCII Operating Definition
This field will be set to the value of the Page Code field in the Command Descriptor Block.
This field will specify the length in bytes of the parameters that follow the Page Length field.
This field will hold the string "SCSI-2 xa.l3l-l99X" terminated with a zero (OOh) character.
10-11 SCSl-2 Functional Specifications
BYTE
10.3.2.5. Hardware Revision Levels
BIT 7 6 5 4 3 2 1
o
Qualifier
I
Peripheral Device Type Page Code = COhRESERVED Page Length = ODh
Capstan Motor Assembly Revision Level Step Motor Assembly Revision Level Sensor Assembly Revision Level Mainboard Assembly Revision Level
Basic Mechanics Assembly Revision Level Head Assembly Revision Level
End Of String = OOh
Table: Hardware Revision Levels Page
This field will normally be set to zero. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to 3.
Peripheral Device Type
This field is normally set to 1. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to IFh.
Page Code
Page Length
Revision Levels
This field will be set to the value of the Page Code field in the Command Descriptor Block.
This field will specify the length in bytes of the parameters that follow the Page Length field.
These are all two ASCII characters representing the revision level of different parts of the Drive's hardware. The string is terminated with a zero (OOh) character.
10-12 SCSl-2 Functional Specifications
)
~.
l/
BYTE 00 01 02 03 04 05 06 07 08 09 10
Qualifier
10.3.2.6. ROM
Software
Code Revision LevelBIT 7 6 5 4 3 2 1
o
Qualifier
I
Peripheral Device Type Page Code .. C1hRESERVED Page Length .. 07h
ROM Software Code Revision Level
End Of String .. OOh
Table: ROM Software Code Revision Level
This field will normally be set to zero. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to 3.
Peripheral Device Type
This field is normally set to 1. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to IFh.
Page Code
Page Length
ROM Software Code Revision Level
This field will be set to the value of the Page Code field in the Command Descriptor Block.
This field will specify the length in bytes of the parameters that follow the Page Length field.
This is 6 ASCII characters representing the software revision and option levels. The string is terminated with a zero (OOh) character.
10-13 SCSI-2 Functional SpeCifICations
BYTE
00 01 02 03 04 05 06 07 08 09 10 11 12
Qualifier
Tandberg Data Inquiry
10.3.2.7. Drive Manufacturing Date
BIT 7 6 5 4 3 2 1
o
Qualifier
I
Peripheral Device TypePage Code
=
C2hRESERVED Page Length
=
09hDrive Manufacturing Date
End Of String
=
OOhTable: Drive Manufacturing Date Page
This field will normally be set to zero. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to 3.
Peripheral Device Type
This field is normally set to 1. When an Unsupported LUN condition exists (LUN field in the Command Descriptor Block or IDENTIFY message is not set to zero), this field will, however, be set to IFh.
Page Code
Page Length
Drive Manufacturing Date
This field will be set to the value of the Page Code field in the Command Descriptor Block.
This field will specify the length in bytes of the parameters that follow the Page Length field.
This is 8 ASCII characters representing the manufacturing date on the format 'MM.DD.YY'. The string is terminated with a zero (OOh)
character. '
10-14 SCSl-2 Functional Specifications
(
10.3.2.8. ROM Software Creation Date
BIT 7 6 5 4 3 2 1
o
Qualifier
I
Peripheral Device TypePage Code = C3h RESERVED Page Length = 09h
ROM Software Creation Date
End Of String = OOh
Table: ROM Software Creation Date Page
, message is not set to zero), this field will, however, be set to 1Fh.
Page Code
Page Length
ROM Software Creation Date
This field will be set to the value of the Page Code field in the Command Descriptor Block.
This field will specify the length in bytes of the parameters that follow the Page Length field.
This is 8 ASCII characters representing the software creation date on the format 'MM.DD.YY'. The string is, terminated with a zero (OOh) character.
10-15 SCSI-2 FuncHonal Specifications
BYTE 00 01 02 03 04 05 06 07 08 09