1. In this study, shading devices like external overhangs, fins (vertical louvres) and interior blinds which were not considered, while they can affect building energy performance and could be studied in future researches.

2. In first case study of Tehran, total energy consumption graphs, less SHGC is better for smaller windows but more SHGC is better for large windows. This reversal in parameter’s influence on energy performance could be studied in future researches.

3. In some cases, which graph lines grow substantially in each single direction from 10% to 90%, in all-direction graph their sharp increasing gets less in larger sizes of fenestration (they bend down). It means where there is more than one side windows, especially four sides, increasing influence is less than increasing fenestration’s size, comparing to single side window. This could be examined more in future.

4. In some cases, there is a repeating critical point in their graphs, in the point of about 30% of fenestration percentage. In this point, a change starts, and the graph line direction get a sudden notable change in slope and even direction. It could be a sharp increase after slow, a deep decrease after slight, begin to rise or fall after constant trade, or even converting or reversing overall. This point of 30% w/w is a challenging topic for future development in fenestration researches.

98 - C h a p t e r 7

References:

1. Building Energy Codes 101, an Introduction, (2010), US Department of Energy,

<https://www.energycodes.gov/sites/default/files/becu/BECU_Codes_101_Intro.pdf>.

2. Building Energy Codes Program, (2016), US Department of Energy,

<https://www.energy.gov/eere/buildings/building-energy-codes-program>.

3. Chow, T.-t., C. Li, et al. (2010), 'Innovative solar windows for cooling-demand climate', Solar Energy Materials and Solar Cells, vol. 94, no. 2, pp. 212-220.

4. Climate of Tehran, (2013), Tehran yearly weather, < https://weather-and-climate.com/>.

5. Code 19: Energy Conservation in Buildings, Ministry of Roads & Urban Development Iran, (2014), pp. 21-43.

6. Cuce, E. and P. M. Cuce, (2016), 'Vacuum glazing for highly insulating windows: Recent developments and future prospects', Renewable and Sustainable Energy Reviews, vol.

54, pp. 1345-1357.

7. DesignBuilder Software Ltd, (2017), Simulation key features,

<https://www.designbuilder.co.uk/>.

8. DesignBuilder Software Ltd, (2017), Simulation Hourly Weather Data,

http://www.designbuilder.co.uk/helpv2/Content/Hourly_Weather_Data.htm 9. Elkins, Dorothy; Elkins, T. H.; Hofmeister, B, (2005), Berlin: The Spatial Structure of a

Divided City, Routledge.

10. Energy Plus, U.S. Department of Energy, (2018), Weather Data,

<https://energyplus.net/weather>

11. EnergyPlus, U.S. Department of Energy, (2018), EnergyPlus Software,

<https://energyplus.net/>

12. Energy performance rating, 2014, National Fenestration Rating Council,

<https://www.nfrc.org/energy-performance-label/>

13. EnEV Energieeinsparverordnung, (2016), EnEV online,

<http://www.enev-online.com/enev_praxishilfen/vergleich_enev_2016_enev_2014_neubau_wohnbau_1 5.04.06.htm>.

14. Fayaz, R. and B. M. Kari, (2009), 'Comparison of energy conservation building codes of Iran, Turkey, Germany, China, ISO 9164 and EN 832', Applied Energy, vol 86, no. 10, pp.

1949-1955.

15. Gao, T., T. Ihara, et al., (2016), 'Perspective of aerogel glazings in energy efficient buildings', Building and Environment, vol. 95, pp. 405-413.

16. Garnier, C., T. Muneer, et al., (2015), 'Super insulated aerogel windows: Impact on daylighting and thermal performance', Building and Environment, vol. 94, Part 1, pp.

231-238.

17. Gasparella, A., G. Pernigotto, et al., (2011), 'Analysis and modelling of window and glazing systems energy performance for a well insulated residential building', Energy and Buildings, vol. 43, no. 4, pp. 1030-1037.

18. Ghisi, E. and J. A. Tinker, (2005), 'An Ideal Window Area concept for energy efficient integration of daylight and artificial light in buildings', Building and Environment, vol.

40, no. 1, pp. 51-61.

19. Goschenhofer, Petra, 2018, 'Energetische Grundlagen zum Hausbau, Energieeffiziente Wohngebäude', (2018), p 11.

20. Gustavsen, A., S. Grynning, et al., (2011), 'Key elements of and material performance targets for highly insulating window frames', Energy and Buildings, vol. 43, no. 10, pp.

2583-2594.

99 - C h a p t e r 7

21. Hassouneh, K., A. Alshboul, et al., (2010), 'Influence of windows on the energy balance of apartment buildings in Amman', Energy Conversion and Management, vol. 51, no. 8, pp. 1583-1591.

22. Hee, W. J., M. A. Alghoul, et al., (2015), 'The role of window glazing on daylighting and energy saving in buildings', Renewable and Sustainable Energy Reviews, vol. 42, pp.

323-343.

23. Husin, S. N. F. S. and Z. Y. H. Harith, (2012), 'The Performance of Daylight through Various Type of Fenestration in Residential Building', Procedia - Social and Behavioral Sciences, vol. 36, pp. 196-203.

24. Ihm, P., L. Park, et al., (2012), 'Impact of window selection on the energy performance of residential buildings in South Korea', Energy Policy, vol. 44, pp. 1-9.

25. Inanici, M. N. and F. N. Demirbilek, (2000), 'Thermal performance optimization of building aspect ratio and south window size in five cities having different climatic characteristics of Turkey', Building and Environment, vol. 35, no.1, pp. 41-52.

26. Iqbal, I. and M. S. Al-Homoud, (2007), 'Parametric analysis of alternative energy conservation measures in an office building in hot and humid climate, Building and Environment, vol. 42, no. 5, pp. 2166-2177.

27. Jaber, S. and S. Ajib, (2011), 'Optimum, technical and energy efficiency design of residential building in Mediterranean region', Energy and Buildings, vol. 43, no. 8, pp.

1829-1834.

28. Jaber, S. and S. Ajib, (2011), 'Thermal and economic windows design for different climate zones', Energy and Buildings, vol. 43, no. 11, pp. 3208-3215.

29. Jelle, B. P., A. Hynd, et al., (2012), 'Fenestration of today and tomorrow: A state-of-the-art review and future research opportunities', Solar Energy Materials and Solar Cells, vol. 96, pp. 1-28.

30. Ko, D.-H., (2009), 'Fenestration guideline for energy and daylight efficiency: Evaluation and prediction of performance in office buildings', Ph.D. thesis, 3370860, Illinois Institute of Technology.

31. Laouadi, A., M. R. Atif, et al., (2002), 'Towards developing skylight design tools for thermal and energy performance of atriums in cold climates', Building and

Environment, vol. 37, no. 12, pp. 1289-1316.

32. Leskovar, V. Ž. and M. Premrov, (2012), 'Influence of glazing size on energy efficiency of timber-frame buildings', Construction and Building Materials, vol 30, pp. 92-99.

33. Li, S. Y., G. A. Niklasson, et al., (2012), 'Thermochromic fenestration with VO2-based materials: Three challenges and how they can be met', Thin Solid Films, vol. 520, no.

10, pp. 3823-3828.

34. Nasrollahi, F., (2009), 'Climate and Energy Responsive Housing in Continental Climates', PhD thesis, Technische Universität Berlin, <https://depositonce.tu-berlin.de/bitstream/11303/2603/1/Dokument_15.pdf>.

35. Ochoa, C. E., M. B. C. Aries, et al., (2012), 'Considerations on design optimization criteria for windows providing low energy consumption and high visual comfort', Applied Energy, vol. 95, pp. 238-245.

36. Persson, M.-L., A. Roos, et al., (2006), 'Influence of window size on the energy balance of low energy houses', Energy and Buildings, vol. 38, no. 3, pp. 181-188.

37. K. Rueckert, R. Schaefer, E. Shahriari (2011). Young Cities Project, Developing Energy-Efficient Urban Fabric in the Tehran-Karaj Region. Tehran, Berlin, Technical University of Berlin.

38. Rose, C., (2015), 'German Energy Saving Ordinance',

<https://passregsos.passiv.de/wiki/German_Energy_Saving_Ordinance_(EnEV_2009)>

100 - C h a p t e r 7

39. Shen, C. and X. Li, (2016), 'Solar heat gain reduction of double glazing window with cooling pipes embedded in venetian blinds by utilizing natural cooling, 'Energy and Buildings', vol. 112, pp. 173-183.

40. Standard Construction Details of Iran, Management and planning organization of Iran, (2010), pp. 34-97.

41. Trząski, A. and J. Rucińska, (2015), 'Energy labeling of windows – Possibilities and limitations, Solar Energy, vol. 120, pp. 158-174.

42. Tsikaloudaki, K., K. Laskos, et al., (2015), 'The energy performance of windows in Mediterranean regions, Energy and Buildings, vol 92, pp. 180-187.

43. Zhang, C., J. Wang, et al., (2016), 'Modeling and thermal performance evaluation of a switchable triple glazing exhaust air window', Applied Thermal Engineering, vol. 92, pp.

8-17.

44. Selecting Windows for Energy Efficiency, (2018), U.S. Department of Energy, <

https://nascsp.org/wp-content/uploads/2018/02/us-doe_selecting-windows-for-energy-efficiency.pdf>

45. Windows And Glazing, (2016), National Institute of Building Sciences,

<https://www.wbdg.org/resources/windows-and-glazing>

46. World Weather Information Service, (2008), Berlin Climate figures,

<https://worldweather.wmo.int/>