CBI-1010 .

VAXBI SCSI Host Adapter User's Manual

~IUI~CMD

s: E TECHNOLOGr~~~~~

~/NC.

(2)

CBI-1010

VAXBI SCSI Host Adapter User's Manual

CMD Technology, Inc.

1 Vanderbilt Irvine, CA 92718 (714) 454-0800

MAN-OOl01a-OOO Rev. 1.3 June 1993

(3)

Copyright

Disclaimer

FCC Notice

Warranty

This manual is copyrighted and all rights are reserved. No portion of this document may be cop- ied, photocopied, reproduced, translated, or reduced to any electronic medium or machine read- able form without prior written consent from CMD Technology, Inc. (CMD).

CMD, CMD Technology, and CBI-1010 are all trademarks of CMD Technology, Inc. All other product and company names are trademarks and registered trademarks of other manufacturers.

Copyright © CMD Technology, Inc. September 1991. All rights reserved.

CMD reserves the right to make changes to this manual and the equipment described herein with- out notice. CMD has made all reasonable efforts to insure that the information in this manual is accurate and complete. However, CMD shall not be liable for any technical or editorial errors or omissions made herein or for incidental, special, or consequential damage of whatsoever nature resulting from the furnishing of this manual, or operation and performance of equipment in con- nection with this manual.

Class A Computing Device:

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communica- tions. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

BASIC WARRANTY -In the absence of any optional warranty or continuing provisions by for- mal agreement, CMD warrants its products in accordance with the schedules listed below. Pur- chaser hereafter mentioned refers at all times to the customer who purchased CMD product(s).

HOST ADAPTER WARRANTY - CMD warrants Host Adapter products of its manufacture to be free from defect in material and workmanship for a period of one year from the date of shipment.

During this period, if the customer experiences difficulties with a CMD Host Adapter and is un- able to resolve the problem via phone with CMD Technical Support, a Return Material Authoriza- tion (RMA) will be issued. Following receipt of an RMA, the Purchaser is responsible for return- ing the product to CMD, freight prepaid. CMD, upon verification of warranty, will repair or re- place at its option the Host Adapter in question, and will then return the product to the Pur- chaser, freight prepaid.

CABLE WARRANTY - All CMD provided cables are warranted for ninety (90) days from the time of shipment. Questionable cables should be returned to CMD, freight prepaid, where they will be repaired or replaced by CMD at its option and returned to the Purchaser, freight prepaid.

GENERAL TERMS - The above warranties shall not apply to expendable components such as fuses, bulbs, and the like, nor to connectors, adapters, and other items not a part of the basic prod- uct. CMD shall have no obligation to make repairs or to cause replacement required through nor- mal wear and tear or necessitated in whole or in part by catastrophe, fault or negligence of the user, improper or unauthorized use of the product, or use of the product in such a manner for which it was not designed, or by causes external to the product, such as, but not limited to, power failure or air conditioning. CMD's sole obligation hereunder shall be to repair or replace any defective product, and, unless stated, pay return transportation costs within the United States of America for such replacement. Purchaser.shall provide labor for removal of the defective prod- uct, shipping charges for return to CMD and installation of its replacement. On-site services are not a part of this warranty. Above warranties are subject to change without notice.

RETURNED MATERIAL - Warranty claims must be received by CMD within the applicable war- ranty period. A replaced product, or part thereof, shall become the property of CMD and shall be returned to CMD at Purchaser's expense. All returned material must be accompanied by a Re- turn Materials Authorization (RMA) number assigned by CMD. For RMA numbers call CMD at (714) 454-0800.

THE EXPRESSED WARRANTIES SET FORTH IN THIS AGREEMENT ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,

(4)

Return and

AND ALL SUCH OTHER WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY CMD. THESE STANDARD EXPRESS WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR LIABILITIES ON THE PART OF CMD FOR DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNEC- TION WITH THE USE OR PERFORMANCE OF THE PRODUCT.

Repair Policy WARRANTY PERIOD

The following warranty period is from the date of shipment:

CMD Host Adapter one year

Cable 90 days

Drive manufacturer's warranty

RETURN FOR CREDIT

The allowable period of return for credit from the date of shipment is as follows

CMD Host Adapter less than 30 days

Cable less than 30 days

Drive not applicable

RETURN FOR REPAIR CMD Host Adapter

In-Warranty (Less than 1 year)

• CMD offers a 15 working day turnaround repair seroice at the cost of parts only. Defective boards will be repaired and returned to the customer within 15 working days from the date of return to CMD.

• CMD also offers two in-warranty 24 hour expediting services:

24 Hour Turnaround Loaner Service:

Under this policy, CMD will ship a loaner in 24 hours during regular working days to the customer for a charge of $100.00 per loaner. Upon receiving the loaner, customer must re- turn the defective board to CMD within seven (7) days for repair. CMD will repair the de- fective board and return the board to the customer. Customer must then return the loaner in seven (7) days after the receipt of the repaired board. Approval for loaner service is based on credit verification.

24 Hour Turnaround Swap Service:

In the case that the defective board is within the first six (6) months of the warranty, CMD, at its own option, offers a 24 hour turnaround swap service. CMD will ship the same model of the board to customer within 24 hours during working days in exchange for the defective board. CMD will swap with a new board if board is not functional upon arrival.

For all other cases, swap will occur with either a new or refurbished board for a charge of

$200.00. CMD does not offer swap services for boards that are purchased more than six months from the date of shipment. Customer is responsible for returning the defective board to CMD within seven (7) days after receipt of the swapped board.

• The remaining warranty period shall apply to the repaired or swapped board.

Out-of-Warranty (more than 1 year)

• CMD offers a 15 working day turnaround repair seroice at a rate of $300.00 plus parts and freight for all out-of-warranty host adapter boards. Defective boards will be repaired and returned to customer within 15 working days starting with date of return to CMD.

• CMD also offers an Out-of-Warranty 24 Hour Turnaround Loaner Service:

Under this policy, CMD will ship the same model loaner in the 24 hour time frame of work- ing days to customer for an additional charge of $100.00 plus freight per loaner. The loaner is for use by the customer during the period that the defective board is being repaired. Cus- tomer is responsible for returning the defective board to CMD within seven days after the receipt of loaner and returning the loaner in seven (7) days once the defective board is re- paired and received. The approval of the loaner service is at CMD's option and based upon customer credit verification.

• CMD will extend warranty for a period of six (6) months on any out of- warranty repaired board.

Cable

In-Warranty (90 days) - free swap.

Out-of-Warranty (90 days) - not applicable.

(5)

Drive

In-Warranty (per manufacturer) - manufacturer charge only.

Out-of-Warranty (per manufacturer) - manufacturer charge plus $100 CMD handling.

RETURN FOR UPGRADE/ UPDATE CMD Host Adapter

In-Warranty (less than 1 year)

• CMD offers a 15 working day turnaround different function upgrade service for boards that can be upgraded to a higher function; and a free 15 working day turnaround ECD Field Upgrade for all its boards. CMD will upgrade the hardware of its board to a higher function for a charge of the difference of list prices of the original and upgraded functions. CMD will also update its board to its latest firmware release at no charge to the customer. Boards will be upgraded/updated and returned to the customer within 15 working days from the date of return to CMD.

• CMD also offers 24 hour turnaround loaner service as stated in "RETURN FOR REPAIR."

• The remaining warranty period shall apply to the updated board. For upgraded boards, CMD will extend warranty for a period of six months.

Out-of-Warranty (More than 1 year)

• CMD offers a 15 working day turnaround different function upgrade service for boards that can be upgraded to a higher function at a charge of the difference of list prices of two func- tions. CMD also offers a free 15 working day turnaround ECD Field Upgrade for all its boards.

Boards will be upgraded/updated and returned to customer within 15 working days from the date of return to CMD.

• CMD also offers 24 hours turnaround Loaner Service as stated in "RETURN FOR REPAIR."

• There will be no warranty extension for same function firmware update. For different func- tion Hardware upgrade, CMD will extend warranty for a period of six (6) months.

Drive-same as in RETURN FOR REPAIR.

SHIPPING CHARGES

The following shipping charges apply to all REPAIR, SWAP, LOANER, and UPGRADE UNITS.

In-Warranty

• Domestic - freight from CMD to customer is to be paid by CMD; freight from customer to CMD is to be paid by customer.

• International- all fees are to be paid by customer (including custom duty and broker fees).

Out-of Warranty

• Domestic - all fees are to be paid by customer.

• International- all fees are to be paid by customer (including custom duty and broker fees).

GENERAL CONDITIONS

All goods returned to CMD including returns for credit, swap returns, loaner returns, and evalu- ation returns shall remain in good condition. Any damage or alteration done by the customer will result in a rejection or additional charge to the customer.

Custom~r must consult CMD Technical Support for authorization of CMD not functional upon arrival boards and swap requests. CMD Sales personnel must be consulted for authorization of returned goods for credit and/ or evaluation.

(6)

Preface

Revision 1.3 of the CBI-IOIO manual contains the following changes from the previous version:

• Instructions for switching between the CBI-IOIO/M and CBI-IOIO/MB have been added to Chapter 3 .

• An error in the ULTRIX Configuration section has been corrected. The error was in steps 3 and 4 of the CBI-IOIO/TM instructions.

Preface vii

(7)

viii Preface

(8)

Table of Contents

1

Introduction 1-1

How to Use this Manual 1-1

Conventions 1-2

2

Features and Specifications 2-1

CBI-I0I0 Features 2-1

Special Features 2-3

Multi-Hosting 2-3

Tape Monitor Utility 2-4

Sync/ Async Mode 2-4

CBI-I0I0 Specifications 2-5

Cabling 2-6

Termination 2-6

3

Installation 3-1

Hard ware Configuration 3-1

Disk and Tape Emulation Selection for the CBI-I0I0/TM 3-2 Switching Between CBI-I0I0/M and CBI-I0I0/MB 3-3

System Node ID 3-4

Differential Mode 3-6

Single-Ended Mode 3-8

Installing the CBI-I0I0 3-9

SCSI Cabling 3-9

SCSI Terminator Power 3-10

SCSI ID for Host Adapter (Initiator) 3-10

CBI-I0I0 Installation Procedures 3-10

Installing SCSI Devices 3-14

Table of Contents ix

(9)

Cable Specifications 3-14

SCSI ID for Target Devices 3-14

SCSI Device Installation Procedures 3-15

4 Setup

4-1

On-Board Utility 4-1

Accessing the Utility 4-1

Changing LUN Offset 4-2

Formatting the Drive 4-3

Qualifying the Drive 4-3

Manually Replacing Bad Sectors 4-4

Additional Utilities 4-4

Displaying SCSI Device and Setting Up Configuration 4-5

Sending SCSI Commands To The Device 4-11

Testing SCSI Device 4-12

Formatting RCT Block 4-13

Completing Utility Functions 4-13

Unit Numbering 4-14

Multi-Hosting Configuration 4-16

VMS Configuration 4-17

ULTRIX Configuration 4-18

CBI-I0I0/T 4-18

CBI-I0I0/M 4-19

CBI-I0I0/MB 4-20

CBI-I0I0/TM 4-21

5 SCSI Basics

5-1

SCSI Glossary 5-1

SCSI Commands 5-2

SCSI Status 5-3

SCSI Messages 5-4

SCSI Single-Ended Signals 5-4

SCSI Differential Signals 5-6

A Supported Devices and Operating Systems

A-1

SCSI Devices A-I

Magnetic disk drives supported A-I

Erasable Optical disk drives supported A-2

Erasable Optical disk cartridge manufacturers A-2 x Table of Contents

(10)

CD ROM disk drives supported A-2

WORM drives supported A-2

Tape drives supported A-2

Jukeboxes supported A-3

Operating Systems A-3

B Troubleshooting

B-1

VMS Analyze/Error Utility B-1

Cables B-3

LED Indicators B-3

CMD Technical Support B-4

C Miscellaneous

C-1

Jumper Settings C-1

Index

Quick Reference Guide

Table of Contents xi

(11)

xii Table of Contents

(12)

List of Figures

2 Features and Specifications

Figure 2-1: Front LED Assignment 2-2

3 Installation

Figure 3-1: Components of the CBI-I0I0 3-2

Figure 3-2: Jumper WI Pin Positions 3-3

Figure 3-3: Differential Card (CBI-I012) Installation 3-7

Figure 3-4: CBI-I012 Components 3-7

Figure 3-5: Single-Ended Card (CBI-I0ll) Installation 3-8

Figure 3-6: CBI-I0ll Components 3-9

Figure 3-7: Back Panel Cabling (Differential) 3-11 Figure 3-8: Back Panel Cabling (Single Ended) 3-12 Figure 3-9: Connectors on the system backplane 3-13

Figure 3-10: SCSI cabling 3-15

4 Setup

Figure 4-1: Utility Main Menu 4-2

Figure 4-2: Utility Sub-menu 4-4

Figure 4-3: Current configuration, default 4-6

Figure 4-4: Configuration change 4-7

Figure 4-5: Synchronous transfer rate change 4-10

Figure 4-6: SCSI host adapter ID change 4-10

Figure 4-7: Disk and Tape Configuration Change 4-11

List of Figures xiii

(13)

5 SCSI Basics

Figure 5-1: Single-Ended SCSI device connector Figure 5-2: Differential SCSI device connector

C Miscellaneous

Figure C-1: CBI-1010 jumper locations Figure C-2: CBI-1010 Silk Screen Rev. C

xiv List of Figures

5-4 5-6

C-3 C-4

(14)

List of Tables

2

Features and Specifications 2-1

Table 2-1: CBI-I0I0 Models 2-2

Table 2-2: LED Indicators 2-3

Table 2-3: Special Feature Support List 2-3

Table 2-4: Controller Specifications 2-5

Table 2-5: Cable Specifications 2-6

3

Installation 3-1

Table 3-1: Default Settings 3-1

Table 3-2: WI Jumper S~ttings 3-3

Table 3-3: CBI-I010/M and CBI-I0I0/MB Settings 3-4 Table 3-4: Map of System Node ID for VAX 6000 3-5

Table 3-5: Connectors and Cables 3-9

4

Setup 4-1

Table 4-1: Default for Unit Numbers 4-14

5

SCSI Basics 5-1

Table 5-1: SCSI Commands (MSCP) 5-2

Table 5-2: SCSI Commands (TMSCP) 5-3

Table 5-3: SCSI Status 5-3

Table 5-4: SCSI Messages 5-4

Table 5-5: SCSI Single-Ended Connector Pin Assignments 5-5 Table 5-6: SCSI Differential Connector Pin Assignments 5-7

List of Tables xv

(15)

A Supported Devices and Operating Systems

Table A-I: Operating Systems Supported by CBI-IOIO

C Miscellaneous

Table C-I: Jumper Settings for the CBI-IOIO·

Table C-2: WI Jumper Settings

xvi List of Tables

A-1 A-3 C-1

C-I C-2

(16)

1

Introduction

This User's Guide explains the basics of your CBI-lOlOTM. It includes information on setting up and configuring the system and the CBI-lOlO for use.

How to Use this Manual

This guide has five chapters and three appendices. Each chapter explains a different aspect of preparing your CBI-lOlO for use. You may refer to the appendices for further configuration and troubleshooting information. The following descriptions summarize each section.

Chapter 1: Introduction explains the purpose of this guide and details the conventions used.

Chapter 2: Features and Specifications describes the CBI-lOlO and details its features and specifications.

Chapter 3: Installation describes hardware configuration and installation procedures for the CBI-lOlO.

Chapter 4: Setup describes the On-Board Utility, set up of special features and software configuration.

Chapter 5: SCSI Library lists a glossary on SCSI terms and gives SCSI status and command codes for the CBI-lOlO.

Appendix A: Supported Devices and Host Computers lists the SCSI devices and Host computers compatible with the CBI-lOlO.

Introduction 1-1

(17)

CBI-1010

Appendix B: Troubleshooting gives some troubleshooting guidelines for the

CBI-IOIO under VMS®.

Appendix C: Jumper Settings list the jumper setting selections available on the CBI-IOIO.

Conventions

The following conventions are used in the CBI-IOIO User's Guide.

Keycaps-Characters in square brackets represent keys on your keyboard. For example, "Press [ENTER]" means press the [ENTER] key. When two or more keys are joined by a plus sign (+), press those keys at the same time.

Commands-Italics text represents a command that can be used on a system, eg., show dev duo

Entering Text or Commands on Screen-Text or commands that must be entered on screen will be in italics and bold as show dev du; be sure to enter the text or command and press [ENTER].

1-2 Introduction

(18)

2

Features and Specifications

This section briefly describes the CBI-I0I0 V AXBI SCSI Host Adapter and details its specifications.

CBI-1010 Features

The CBI-I0I0 is an intelligent high performance VAXBI SCSI host adapter that is fully compatible with the DEC Mass Storage Control Protocol (MSCP) and Tape Mass Storage Control Protocol (TMSCP). Each CBI-I0I0 is fully licensed by Digital and is built around DEC's own BIIC interface chip.

The CBI-I0I0 can be used with the 5800, 6000, 8000, and 9000 series V AXBI systems. It supports VMS, UL TRIX, and selected UNIX operating systems which use DU!TU drivers.

The CBI-I0I0 supports either a single-ended or differential SCSI channel. A single-ended SCSI channel can be used for connecting up to 9.9 feet of cable (when the transfer rate is 10 MBytes/second) while a differential SCSI channel can be used to connect up to 80 feet of cable.

The CBI-I0I0 features Octaword DMA master transfers, virtual data buffer, command queuing, dynamic defect management, standard SCSI bus

arbitration, disconnect and reconnect capabilities, and multiple host

capability. Up to seven SCSI devices (either single-ended or differential) can be connected to the CBI-I0I0 SCSI port with SCSI bus data transfer rate up to 10-MB/sec in synchronous (sync) mode and 7-MB/sec in asynchronous (async) mode.

Features and Specifications 2-1

(19)

CBI-1010

The CBl-1010 supports a variety of sync/ Async SCSI devices including magnetic disk, tape, and optical disk drives. Table 2-1 lists the devices

supported by the different CBl-1010 models.

Tab\e 2-1

CB\-1 01

Models

supports disk drives only supports tape drives only

supports disk and tape drives simultallE oUSly supports disk drives only

CBI-l0l0/M CBI-l0l0/T

CBI-l0l0I™

CBI-l0l0

1MB

The CBI-1010 has an On-Board Utility for yOU to format and configure the SCSI drives, scan bad blocks and replace them automaticallY, and test SCSI

disk and tape drives.

The CBI-101 0haS

an on-board non-volatile

RAM

(NoVRAM-) to store the drive Logical Unit Number Offset and other important information to handle

configuration of devices.

The CBI-1010 features six LEos--three green, one red, and twO yellOW. These LEDs are visible from the front or top of the chassis when the system is

running and are labeled as shown in Figure 2-1.

YELLOW 0998

fIgure 2-1: front LEO Ass\gnrn ent

2-2 Features and specificatiOns

(20)

CBI-1010

Table 2-2 describes the conditions of CBI-IOIO when LED's are lit.

Table 2-2 LED Indicators

LED Color

. DS1-Right red DS1-Left green

DS2-Left green DS2-Right green D998/ yellow D999

Special Features

Indication

Error condition occurred.

Power-up OK and activity indicator. Upon power up, this LED lights when the CQD-220 succeeds in the self-

diagnostic testing. During normal operation, this LED will blink to show controller activity.

SCSI controller chip Single-ended mode enabled when lit.

Differential mode enabled with not lit.

Terminator power pin is supplied with power. Refer to Figure 3-1.

Self-test passed.

The CBI-IOIO supports special features that pertain to the different CBI-IOIO models as listed Table 2-3.

Table 2-3 Special Feature Support List

Model Multi-Hosting TMU

CBI-1010/TM Yes Yes

CBI-1010/T Yes Yes

CBI-1010/M Yes No

CBI-1010 1MB Yes No

Multi-Hosting

CBI-IOIO gives you the ability to completely share an array of disks and tapes between multiple VAX systems running VAX cluster software. CMD's

multi-host solution can support disk, tape, and optical devices including juke- boxes. Multi-hosting instructions are given in Chapter 4, under

II Additional Utilities." Refer to Appendix A for supported disk and tape devices. Refer to Chapter 4 for configuration instructions.

Features and Specifications 2-3

(21)

CBI-1010

Tape Monitor Utility

The Tape Monitor UtilityTM (TMU) is an application software developed by CMD Teclmology and work exclusively with CMD SCSI host adapters as an optional feature for VAX/VMS systems.

This Tape Monitor UtilityTM runs under VMS and displays the tape drive ven- dor identification, drive firmware revision, the remaining tape capacity, per- centage of rewrites during writes or percentage of ECC retrys during reads, and current tape operations such as read, write, write file mark, space, re- wind, etc. You can install multiple CBI-IOIOs and tape drives in one site and observe all tape activity from any VAX terminal locally or across the network without any additional add-in hardware. You also can open a file to log all the information during unattended backup.

To install the Tape Monitor Utility, use On-Board Utility (Chapter 4,

subsection 1/ Additional Utilities") to enable TMU since the factory setting for TMU OFF. Then follow the instructions given in the accompanying CMD Tape Monitor Utility User's Manual part number MAN-OOOTMU-OOl.

SynclAsync Mode

The CBI-IOIO comes standard in synchronous mode. Most SCSI devices support synchronous mode. However, you can change the CBI-IOIO to asynchronous mode using the On-Board Utility in Chapter 4.

In Sync mode, CBI-IOIO will automatically negotiate with each SCSI device connected to find out whether the Sync mode is supported by the device.

In Async mode, CBI-IOIO will communicate with the SCSI device

asynchronously even if the SCSI device supports Sync mode. Most of the Sync SCSI devices also support Async mode.

2-4 Features and Specifications

(22)

CBI-1010

CBI-1 01 0 Specifications

Table 2-4 on the following page lists the Controller Specifications for the CBI-IOIO.

Table 2-4 Controller Specifications Emulation

Bus Interface Adapter Size Interrupt Vector Transfer Mode Command Queuing Data Buffer Capacity Defect Management:

Software Supported Multiple-Hosting Formatting

Optional Software LED Indicators

Peripheral Interface SCSI Transfer Rate SCSI Bus Parity Devices Supported System Performance SCSI Driver/Receiver SCSI Cable Length

Operating Temperature Relative Humidity Power Requirement

MSCP (DU driver) / TMSCP (TU driver) VAXBI

Single V AXBI slot Software programmable Octaword DMA master

32 Commands with optimized seek Virtual data buffer

Dynamic defect management

VMS, ULTRIX and selected UNIX versions

Support multiple-hosting for disks, optical drives and tapes.

On board format and bad block replacement (ISO standard for optical erasable disk format)

Tape monitor utility (TMU)

Self test, error conditions, single-ended SCSI enable, single- ended terminator power, differential SCSI enable,

differential terminator power

Small Computer System Interface (SCSI) 10.0-MB/sec in Synchronous mode 7.0-MB/sec in Asynchronous mode Odd parity

Up to 7 SCSI devices

Support disconnect/reconnect capability and multiple host configuration

Single-ended or differential

Single-ended, up to 9.9 ft (3 meters) recommended at 10 MBytes / second transfer rate

Differential, up to 80 ft (25 meters) 5° C to 50° C

10% to 900/0 , Non-condensing

+5V DC 6.0A, +12V DC 14mA, -12V DC 6mA

Features and Specifications 2-5

(23)

CBI-1010

Cabling

The CBI-1010 will operate in single-ended or differential mode; however, CMD Technology strongly recommends the use of differential mode when the data transfer rate exceeds five megabytes per second. If you have no choice but to use single-ended mode at a high transfer rate, the SCSI-3 proposal rec- ommends that the total internal and external cable length should be no longer than three (3) meters or 9.9 feet when the transfer rate is 10 MBytes/second.

Furthermore, the single-ended cable should meet or exceed the following specifications.

Table 2-5 Cable Specifications

Characteristic Impedance Signal Attenuation Pair-to-pair Propagation Delay Delta

DC Resistance Termination

No less than 90 ohms and no greater than 140 ohms

.095 dB maximum per meter at 5 MHz .15 nanoseconds maximum per meter

.23 ohms maximum per meter at 20 degrees C

The single-ended daughter card adapter for the CBI-1010 employs active ter- mination. Some SCSI devices still use passive termination, which is inade- quate at high transfer rates. If your system is running in single-ended mode at transfer rates in excess of five megabytes per second and the CBI-1010 is at one end of the SCSI bus, you must use active termination or some other type of high-performance termination at the other end of the bus.

2-6 Features and Specifications

(24)

3

Installation

This chapter details hardware configuration and installation for the CBI-1010.

The CBI-1010 must be configured first, installed in the system second, and SCSI devices installed last. This chapter is organized in the order the CBI-1010 must be installed; after completing hardware installation, refer to "Setup" in Chapter 4. Features not selectable here can be selected through the On-Board Utility in Chapter 4.

Hardware Configuration

This section details setting up various features for the CBI-1010 before install- ing it inside a system. Be sure to follow the instructions listed in each subsec- tion for proper configuration. Table 3-1 illustrates the default settings for each CBI-1010 model.

Table 3-1 Default Settings

Model Wl(1-3) Wl(2-4) W5(1-2) U9

CBI-IOIO/TM OUT OUT OUT PAL PIK08

CBI-IOIO/T OUT OUT OUT PAL PIK28

CBI-IOIO/M OUT OUT OUT PALPIK29

CBI-IOIO/MB OUT OUT IN PAL PIK58A

Note that (F) means factory setting.

Figure 3-1 illustrates the components on the CBI-1010.

Installation 3-1

(25)

CBI-tOtO

CPU

--~~ DID~fmml .. ' 3

'---~ 1 ( 1"---_.(, _ _ _ "II~-~

~_-_~

__ (::::::::::3 (:::::::3 (:::::::3(::::::::::1

- (:::::::3 -

1

~

1 4

~

I

J

....---.. ~::=::::{ IDI:::::::::::.:~ :::::::::::::~:::::::~ ~:::::::~

'---_--' (:::::::3 .::::::::::::3 C:::::::::::I:::::::3 (:::::::3

1:::::::::::3 (:::::::3~~1~:::~:::~::~::~::3~~~~~~~~~

1:::::::::::3 '---- ... _-.,... ... (:::::::3

~c::J D" II IIII II C:::::::3

~

(:::::::3

(:::::::3

D

~ < <

U9

VUlt CHIP

c::J c::J

c:::::>

--1.:::m!ll!!lIIIl111mDJ ~---,<r=~1

, D

(::::::::3 (:::::::3 (:::::::3 (:::::::J

(:::::::3 (:::::::3 C:::::J C::::::::::3 C:::::3

C3

q~W8::J JE

(:: :::::< '---'

Figure 3·1: Components of the CBI·1 01 0

Disk and Tape Emulation Selection for the CBI-1 01 O/TM

The CBI-IOIO/TM is a multiple function controller. When you configure the CBI-IOIO/TM as a single function controller (configured through RS-232 Util- ity as 0 disk or 0 tape) the unused function must be disabled. You can disable one of the functions shown below, see Table 3-2 for different configurations.

• To disable tape function, install a shunt on pins I and 3 of jumper WI.

See Figure 3-2 for location of WI and pin positions.

• To disable disk function, install a shunt on pins 2 and 4 of jumper WI.

See Figure 3-2 for location of WI and pin positions.

3-2 Installation

(26)

CBI-1010

Table 3-2 W1 Jumper Settings Pins 1 & 3

OUT IN OUT

Pins 2 & 4 OUT OUT

IN

Description

CBI-IOIO/TM with PAL PIK08 in location U9 (F)

CBI-IOIO/TM configured for disk only with PAL PIK08 in location U9

CBI-IOIO/TM configured for tape only with PAL PIK08 in location U9

Note that (F) means factory setting.

0

1: : : : :

::S[@ C::::::::J 1::::::::::: 3

:::3- [:::::: ::JI:::: ::: ::J 1::::::::::: 3

::3 I: : : : : : : : : : : 51: : : : : : : : : J I: : : : : : : : : J

Figure 3·2: Jumper W1 Pin Positions

Switching Between CBI-1010/M and CBI-1010/MB

Both the CBI-lOlO/M and CBI-lOlO/MB support disk drives only, but the CBI- 1010/M offers KLESI emulation, while the CBI-lOlO /MB offers KDB50 emula- tion, which is necessary for bootability on VAX 6000 systems. Switching be- tween the CBI-lOlO/M and CBI-IOIO/MB models is a simple matter of chang- ing the PAL at location U9 and either removing or installing the jumper at WS. All CBI-IOIO/M adapters come with PAL PIK29 installed at U9 and PAL PIK58A as an accessory. Likewise, all CBI-IOIO/MB adapters come with PAL PIK58A installed at U9 and PAL PIK29 as an accessory.

Be sure to turn off power to the adapter before you switch the PAL at U9. Use a screwdriver to pry the PAL loose and then remove it with your fingers. In-

Installation 3-3

(27)

CBI-1010

sert the alternative PAL and press down until it is fully seated. Make sure that the alignment of the notch at one end of the PAL is identical to the sur- rounding chips. This will assure a proper pin-one match. Before restoring power, change the jumper at W5 to the appropriate setting for the model you desire. Table 3-3 shows the EPROM and jumper settings for each model.

Table 3-3 CBI-1 01 OIM and CBI-1 01 O/MB Settings Model

CBI-IOIO/M CBI-IOIO/MB System Node 10

Emulation KLESI KDB50

W5 OUT IN

U9

PAL PIK29 installed PAL PIK58A installed

Care must be taken when installing a CBI-I0I0 to avoid having the operating system change the physical device names of the currently installed devices.

During auto configure, each device found is given a unique device name. The device names are expressed as:

ddcu where

dd

=

type of device (Le. MU,DU,PT,PU) c

=

Controller designator (A,B,C ... ) u

=

Unit number

The device name is determined by the physical address of the controllers port registers OP /SA). Since these addresses are fixed within the CBI-I0I0, there are no concerns with configuring the device type. Refer to Chapter 4, Table 4-1 for unit numbers.

The controller designator is derived by the operating system as it scans I/O space. The first MSCP disk controller found is given the letter' A', the second MSCP disk controller 'B' and so on. This will generate devices DUAx/PUAx, DUBx/PUBx, incrementing the controller letter until all disk controllers are found. The same is true for each TMSCP tape controller, yielding devices MUAx/PTAx, MUBx/PTBx and so on.

The scan will start at node 0 and will work its way up to the last node ID within the system. On native BI systems (Le. 8200/8250/8350), the node ID of the BI is the system node ID. In these systems, the system ID's range from

o

to 15.

3-4 Installation

(28)

CBI-1010

On systems where the BI is the system I/O bus (i.e. 58xx, 85xx, 8700, 8800 and aIl6000's), the system node ID does not match the BI node ID. For example, a VAX 6000 machine has 240 system node ID's. The XMI bus has 15 nodes each logically capable of containing a bus adapter with 16 node ID of its own.

Physically this arrangement is not permissible, however, this is how VMS looks at the system.

Table 3-4 shows a map of system node ID's for a VAX 6000 type machine.

Table 3-4 Map of System Node 10 for VAX 6000

XMI node System nodes

1 0-15

2 16 - 31

3 32 - 47

4 48 - 63

5 64 - 79

6 80 - 95

7 96 - 111

8 112 - 127

9 128 - 143

10 144 - 159

11 160 - 175

12 176 - 191

13 192 - 207

14 208 - 223

15 224 - 239

It is desirable to install the CBI-I0I0 at a system node ID that will not change the physical device names of the currently installed devices. This is

accomplished by installing the CBI-l0l0 at a higher system node ID than any other currently installed device of the same type.

The CBI-I0I0/T is device type PT /MU and should be installed at a higher system node ID than other TMSCP tape controllers. The CBI-I010 /M and CBI- 1010/MB is a device type PU/DU and should be installed at a higher system node ID than other MSCP disk controllers. The CBI-I0I0/TM is a device type of PU /DU and PT /MU and should be installed at a higher system node ID than other MSCP disk and TMSCP tape controllers.

Installation 3-5

(29)

CBI-1010

If you do not adhere to these guidelines, currently installed devices that have a higher system node ID than the CBI-lOlO will have their controller designa- tor changed (incremented by the number of CBI-lOlO's installed).

As an example, if the current system has a KDB-50 disk controller installed at XMI node IS, BI node 4, (system node ID 228) and a CBI-lOlO/M,

CBI-lOlO/TM or CBI-lOlO/MB installed at XMI node 14, BI node 4, (system node ID 212), the controller designator for the KDB-50 will be incremented from' A'to 'B' and the CBI-lOlO will have the controller designator of 'A'.

Differential Mode

The CBI-lOlO supports either single-ended or differential SCSI modes. The CBI-lOlO SCSI port is factory configured to your specifications. If for any rea- son you need to convert the CBI-lOlO from single-ended SCSI mode to differ- ential, follow these instructions.

NOTE Use only the components supplied by CMD.

1 Remove the single-ended SCSI daughter card (CBI-lOll) from the lower left comer of the CBI-lOlO board.

2 Install the differential SCSI daughter card (CBI-1012) at the same loca- tion of the CBI-lOlO board. Make sure to align Jl of the daughter card with Jl of the CBI-lOlO board. See figure 3-3.

3-6 Installation

(30)

CBI-tOtO

J1 J2

Figure 3-3: Differential Card (CBI-1012) Installation

Figure 3-4 illustrates the components of the CBI-I012 differential daughter card. The terminator resistors are located at U22 and U23.

I

RN1

II

RN2

I

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Jl

~ Q

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ~~

8~~ ~ [§J ~ ~ @]cm

~

@J CID

~

[ill @J T.r

~Cill@]

~@] ~ 00 ~ ~ 00 00

I~I CTID~(~)Sff~ [(;l)Ta(~) ~

u~ ~ ~ 00 Lfu ~

:J

OOOOOOOOO:S

OOOOOOOOO~ @J ~~

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ~

@(gQ)

00000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 ~ I" I

O~~ 0 0 0 0 0 0 0 J2 000 0 000 OU

0

30 . C21 .

Figure 3-4: CBI-1 012 Components

Installation 3-7

(31)

CBI-1010

Single-Ended Mode

The CBI-I0I0 is factory configured to user specifications. However, if you need to convert the CBI-I0I0 from differential to single-ended, follow these instructions.

1 Remove the differential SCSI daughter card (CBI-I012) from the lower left comer of the CBI-I0I0 board.

2 Install the single-ended SCSI daughter card (CBI-I0ll) at the same loca- tion of the CBI-I0I0 board. Make sure to align Jl of the daughter card with Jl of the CBI-I0I0 board. See figure 3-5.

J1 J2

Figure 3-5: Single-Ended Card (CBI-1 011) Installation

Figure 3-6 illustrates the components of the CBI-I0ll single-ended daughter card. The terminator resistors are located at RNI and RN2.

3-8 Installation

(32)

Jl 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0000000000000000000000000

RNl RN2

~---~

( C2 )

J2 0000000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Figure 3-6: CBI-1011 Components

Installing the CBI-1 01 0

CBI-1010

Installing the CBI-IOIO involves installing the board, cables, terminating the SCSI bus, identifying and testing SCSI devices with the On-Board Utility. This section explains these topics prior to listing installation procedures; carefully read the explanations first.

SCSI Cabling

The V AXBI systems provide two 30-pin connectors in the backplane for every one of the VAXBI Zero Insertion Force (ZIF) connectors JC, JD, and JE. The 30-pin connector on the component side of the CBI-IOIO is defined as

connector CONI. The 30-pin connector on the solder side of the CBI-IOIO is defined as connector CON2 (see Figure 3-4 for details). Table 3-5 lists the connectors and cables for the CBI-IOIO.

Table 3-5 Connectors and Cables Connector

JE

Connector - CONl Single-Ended/Differential signals

Connector - CON2

On-Board RS-232 Utility & Single- Ended/Differential signals

The CBI-IOIO comes with one three-foot SCSI I/O cable (including RS-232 utility interface) and system back panel adapter kit. The I/O cable is a 60-con- ductor cable. One end has two 30-pin connectors and the other end has 50-pin SCSI connector and a IO-pin connector.

Installation 3-9

(33)

CBI-1010

NOTE CMD strongly recommends the use of differential mode in systems employing transfer rates in excess of five megabytes per second. If you have no alternative but to use single-ended mode, the SCSI -3 proposal recom- mends that the total length of the SCSI cable be no longer than three meters (about 9.9 feet) at 10 megabytes per second. See page 2-6 for more details.

SCSI Terminator Power

Typically the initiator (SCSI host adapter) supplies terminator power, +5-volts, to the SCSI bus. Because the CBI-lOlO is considered an initiator to the SCSI devices, the terminator power option of the CBI-lOlO needs to be enabled.

The CBI-lOlO supplies terminator power to the TERMPWR pins of single- ended/ differential SCSI connector (JE) through a polyswitch and jumper block, WB. (Check Tables 5-5 and 5-6 for pin assignments.)

SCSI 10 for Host Adapter (Initiator)

Each device on the SCSI bus requires a unique SCSI Identification address (0 to 7). SCSI ID 7 has the highest priority on the bus and SCSI ID

a

has the lowest priority.

The CBI-lOlO plays the role of initiator and is factory configured to SCSI ID 7.

To alter the Host Adapter SCSI ID, change NOVRAM settings through the On-Board RS-232 Utility given in Chapter 4.

CBI-1 010 Installation Procedures

1 Make sure the system is powered OFF. Make sure the CBI-IOIO is configured as given in the section, "Hardware Configuration."

WARNING Make sure you are wearing anti-static wrist straps.

2 Choose a correct slot for installing the CBI-lOlO by reading the section

"System Node ID."

3 Install the CBI-lOlO in the correct slot with the ZIF connectors set into the system's backplane; push the ZIF handle down to clamp the CBI-IOlO into place.

3-10 Installation

(34)

CBI-tOtO

48 Differential Configuration: Install the back panel into the back of the system with the ribbon cable inside the system. If necessary, move the external connector to the "SCSI Differential" slot on the back panel by unscrewing the connector from the "SCSI Single Ended" slot and the plate from the "SCSI Differential" slot. Swap the plate and the connector and screw them both back into place. (See Figure 3-7.)

JE CON1

JE CON2

Ribbon Cable SCSI Differential Slot

Figure 3-7: Back Panel Cabling (Differential)

4b Single Ended Configuration: Install the back panel into the back of the system with the ribbon cable inside the system. If necessary, move the external connector to the "SCSI Single Ended" slot on the back panel by unscrewing the connector from the "SCSI Differential" slot and the plate from the "SCSI Single Ended" slot. Swap the plate and the connector and screw them both back into place. (See Figure 3-8.)

Installation 3-11

(35)

CBI-1D10

JE CON1

JE CON2

Ribbon Cable

Figure 3·8: Back Panel Cabling (Single Ended)

5 Locate the 60-pin ribbon cable and connect cable labeled JE CONI to JE CONI of the backplane. (See Figure 3-9 for connectors on the system backplane.)

WARNING Pin 1 of the cable must match CONi pin 1 of the backplane.

3-12 Installation

(36)

Component side of CBI-lOl 0

Blue Node ID plug----l

CONl pin

• •

• •

• •

• • CONl pin

• •

• •

• •

• •

• •

• •

• •

• •

Solder side of CBI- 1 01 0

• •

JA Connector JB Connector

JC Connector

e-+---+--CON2 pin

JD Connector

e-+---+--CON2 pin

' - - _ - - - 1 . - _ - - '

CONl pin • • • •

• •

• • •

• • •

• • • •

• •

• • •

• • • •

• • • • JE Connector

• •

• • • •

• •

• • • •

• • ~__+_-CON2 pin

L..-...J.. _ _ -'----_-1-...J

Figure 3·9: Connectors on the system backplane

6 Connect JE CON2 of the ribbon cable to JE CON2 of the backplane.

CBI-tOtO

7 Connect the IO-pin RS-232 cable to the back panel at JI (see Figure 3- 7 for differential configurations and Figure 3-8 for single ended con- figurations.)

Installation 3-13

(37)

CBI-1010

Installing SCSI Devices

This section details installing devices from the connectors of the back panel adapter kit to the SCSI devices~ Read carefully the subsections, "Cable

Specifications" and "SCSI ID for Target Devices" before installing the devices.

Cable Specifications

Single-ended and differential cable specifications vary; see the appropriate paragraph below for cable specifications before attempting to install devices.

See page 2-6 for a discussion of cabling issues in systems running at high transfer rates.

Single-ended:

• When the CBI-IOIO and the SCSI devices are installed in the same cabinet that meets EMI/RFI shielding requirements, a 25-conductor twisted pair ca- ble must be used for connecting the CBI-IOIO (JE) and the SCSI devices.

• When the CBI-IOIO and the SCSI devices are installed in separate cabinets, a shielded twisted pair cable must be used to meet FCC requirements.

• A minimum conductor size of 2S-AWG must be used to minimize noise effects and ensure proper distribution of optional terminator power.

• The maximum cable length is 3.0 meters or 9.9 feet in single-ended mode at 10 megabytes per second.

Differential:

• When the CBI-IOIO and the SCSI devices are installed in the same cabinet that meets EMI/RFI shielding requirements, a 25-conductor twisted pair ca- ble must be used for connecting the CBI-IOIO (JE) and the SCSI devices.

• When the CBI-IOIO and the SCSI devices are installed in separated cabi- nets, a shielded twisted pair cable must be used to connect the SCSI de- vices from the back panel adapter kit meeting FCC requirements. Other- wise, crosstalk between adjacent signals causing spurious pulses on differ- ential signals will occurs even at slow data transfer rates and short cable distances. Each pair should be connected to the same signal, one wire to the positive signal, and the other wire to the negative.

• Cables should consist of conductors of 26-AWG or 2S-AWG.

• The maximum cable length is 25 meters or SO feet in differential mode.

SCSI 10 for Target Devices

Each SCSI device (initiator or target) on the SCSI bus requires a unique SCSI ID number. Since the CBI-IOIO has been set to SCSI ID 7 (initiator), target

3-14 Installation

(38)

CBI-1010

devices must be set from SCSI ID 0 to 6. Normally, the assignment of SCSI Target ID starts with SCSI ID 0 on single function boards.

The factory setting of the CBI-I0I0/TM is four disk devices (SCSI ID=O to 3) and three tape devices (SCSI ID=4 to 6). If you have more than four disks drives or three tapes drives you must use the On-Board Utility to change the configuration; if you do not, you do not need to change the configuration.

SCSI Device Installation Procedures

To install SCSI devices follow the procedures below:

1 Connect SCSI cables as listed below for the specified mode:

For single-ended mode: Connect a SCSI cable from the back panel at the la- bel "Single-Ended" to the SCSI devices (see "Cable Specifications"). The total of the internal and external cable lengths must not exceed 9.9 feet at 10 MBytes/ second. See Figure 3-10.

For differential mode: Connect a SCSI cable from the back panel at the la- bel "Singled-Ended" to the SCSI devices (see "Cable Specifications").

The total of the internal·and external cable lengths must not exceed 80 feet. See Figure 3-10.

SCSI Bus Cable

SCSIID=7 T

CBI-1010 in Host Computer Figure 3·10: SCSI cabling

SCSI Device

SCSI Device

SCSIID=2 T

SCSI Device

T indicates SCSI bus termination.

2 Terminate the physical ends of the SCSI bus by terminating the last SCSI device with on-board termination (see manufacturer's documentation) or by using an external terminator. Be sure devices in the middle of the SCSI bus are not terminated (see Figure 3-10).

Installation 3-15

(39)

CBI-1010

The CBI-IOIO is factory configured with on-board termination.

3 Set the devices SCSI ID numbers to the specifications set forth in "SCSI ID for Target Devices" (see manufacturer's documentation for setting devices SCSI ID).

NOTE For multi-hosting refer to section, "Multi-Hosting Configuration."

3-16 Installation

(40)

4

Setup

This chapter will assist you in setting up the CBI-IOIO and your system for use.

On-Board Utility

The CBI-IOIO SCSI host adapter comes with the general purpose RS-232 util- ity for all DEC VAXBI systems. The On-Board utility can test the VAXBI slot, SCSI cable, and SCSI devices connected to the CBI-IOIO. Be sure to complete utility functions, explained at the end of this chapter.

Accessing the Utility

To access the RS-232 utility, follow the instructions below.

1 Connect a terminal to the CBI-1010's RS-232 port (DB-25 connector or DEC compatible RJ-11/Modified Module 423 Jack connector of the back panel adapter kit).

2 Set the terminal baud rate to 9600 (8-bit data, I-stop bit, no parity).

Setup 4-1

(41)

CBI-1010

4-2 Setup

3 Halt the system's CPU, reset the system, and hit carriage return on the terminal. The main menu will display as shown in Figure 4-1 on the following page.

SCSI HOST ADAPTER UTILITY (REV. YYYXZZ)

x

= EXIT

[DISK]

1 = LOGICAL UNIT NUMBER OFFSET 2 = FORMAT DRIVE

3 = QUALI FY DRIVE

4 = MANUALLY REPLACE BAD BLOCKS 5 = ADDITONAL UTILITIES

SELECT OPTION ?

Figure 4-1: Utility Main Menu

[TAPE]

6 = LOGICAL UNIT NUMBER OFFSET 7 = ADDITIONAL UTILITIES

Once the main utility menu shows up, you can key in the number to select the desired option. Press [CTRL] + C at any time to return to the main menu.

4 Refer the the next subsections for configurations. When completed, unplug the terminal, reset the system, and boot. DO NOT use the On- Board Utility while the system is running.

Changing LUN Offset

When a system has a HSC or in a VAX cluster it will be necessary to

change the LUN (Logical Unit Number) offset. Each MSCP drive requires a different Unit Number so that the unit numbers are not duplicated. If there are no other MSCP controllers in the system, the L UN offset can be

o.

If there exists another MSCP controller with four drives (0 to 3), then the LUN offset should be four or above. In the case that LUN offset is equal to 10, SCSI ID 0 will be DUBIO and SCSI ID 1 will be DUB1l. The drives will show up as such DUAO, DUAl, DUA2, DUA3, DUBIO, DUB11 (see section, "SCSI ID for Target Drives" in Chapter 3 for explanation).

1 Select option 1 from the main menu for disk drives; 6 for tape drives.

2 Enter the new value for LUN offset at the statement: PRESENT LUN OFFSET = 0, ENTER NEW VALUE:

(42)

CBI-1010

3 At the statement: SAVE NEW CONFIGURATION (Y or N)? enter Y.

4 The monitor will display COMPLETE when finished executing.

Formatting the Drive

This section details formatting a drive. The CBI-IOIO issues Format Unit Command to the selected SCSI disk drive and requests it to map out the defects on the Manufacture Defect List (MDL). Remember formatting a drive will rewrite all the sectors of that drive.

CMD recommends that you format all new drives. To format a drive, follow the steps below:

1 Select option 2 from the main menu.

2 Enter the device number from 0 to 6 in the statement: ENTER DEVICE NUMBER 0 TO 6 :

3 At the statement: *** WILL DESTROY DATA ON DEVICE X, ARE YOU SURE? en- ter Y if you want to continue.

4 The monitor displays WAIT while the drive is executing the format process.

5 The monitor will display COMPLETE when finished executing.

Qualifying the Drive

After formatting the device, CMD recommends you qualify devices by running this procedure at lease once without errors detected. The qualify program writes different patterns to the drive and then verifies the data. If there are any bad sectors, the sectors will automatically be replaced and the statement XX XXXXXXXX BAD BLOCK REPLACED will appear. Follow the

instructions below for qualifying a drive.

1 Select option 3 from the main menu.

2 Enter the device number at the statement: QUALIFY DEVICE NUMBER

<0 TO 6>:

3 At the statement: *** WILL DESTROY DATA ON THIS DEVICE, ARE YOU SURE?

enter Y if you want to continue.

Setup 4-3

(43)

CBI-1010

4-4 Setup

4 The monitor will display QUALIFY STARTED <SEQUENTIAL WRITE AND READ>! <HIT <BREAK> TO ABORT>.

5 The monitor will display TESTING LOOP COUNT AND BLOCK NUMBER:

6 Press [BREAK] to exit back to the main menu after you are satisfied with the qualifying process.

Manually Replacing Bad Sectors

This option allows you to replace bad sectors manually. The controller

supports dynamic defect management which replaces defective sectors on-line so there is no need to manually replace bad sectors. However, if you wish to replace bad sectors manually follow these instructions; remember that any data in the sector will be lost:

1 Select option 4 from the main menu.

2 Enter the device number at the statement: DEVICE NUMBER? DEV <0 TO 6>:

3 Enter the logical block number in HEX at the statement: ENTER THE BAD BLOCK NUMBER <HEX>:

4 The monitor will display -BAD BLOCK REPLACED-when finished executing.

Additional Utilities

To access additional utilities for disk drives, select option 5 from the main menu. To access additional utilities for tape drives, select option 7 from the main menu. The additional utilities menu will display as shown in Figure 4-2.

ADDITIONAL UTILITIES (REV. YVYxZ2.) SN

=

1278X

D = DISPLAY SCSI DEVICE AND SET UP CONFIGURATION S = SEND SCSI COMMAND TO THE DEVICE

T = TEST SCSI DEVICE R = FORMAT RCT BLOCK SELECT OPTION?

Figure 4-2: Utility Sub-menu

(44)

CBI·1010

Displaying SCSI Device and Setting Up Configuration

Selection 'D' can be used to change the controller default configurations such as those listed below:

• reset to default

• number of disk and tape devices supported

• SCSI ID of the CBI-IOIO

• SCSI reset enable / disable

• SCSI disconnect enable/ disable

• sync/async mode selection

• tape buffer mode enable/ disable

• prevent medium removal enable/disable

• disk write with verify enable/disable

• Tape Monitor Utility (TMU) enable/disable

• Tape Fast Search enable/disable

• SCSI transfer rate selection

• remote density mode enable/disable

• default tape enable/disable

• reconfigure device

• autoboot start from floppy enable/disable

• write protect from controller jumper setting

• truncate disk size for volume shadowing

• eject removable disk cartridge after dismount

This utility can also scan/display the SCSI devices attached to the CBI-IOIO.

The CBI-IOIO/TM will be shown as an example in the following display.

Setup 4-5

Referenzen

ÄHNLICHE DOKUMENTE

By dividing the SCSI bus into independent single-ended and LVD segments, the AIC-3860 supports legacy devices without limiting performance or LVD segment cable length.. (see

Switch S3 on the right edge of the differential adapter (under the 68-pin J2 connector) should be toggled toward the J2 connector to perform differential analysis. On the

Enter y to confirm your selection for the swap device. + Successful edit of root and swap specification in Isys/sunX/conf/RIMFIRE. [The next step is mandatory for driver

The adapter then extracts the SCSI command from the parameter block and sends it over the SCSI bus, where the SCSI compatible disk controller in the drive

If a SCSI bus reset occurs after a Target Mode Disable command has been sent to the RF3880 (at the time the Host is waiting for the TME field of the Target Selection Data Structure

• Your peripheral works with the HP SCSI driver, but you want information about the HP SCSI I/O Subsystem. • You might be a hardware engineer designing a new

Thus the next command can be issued to a device as soon as the SCSI bus is available and a device is ready for it Because commands are queued, the VI SCSI 4210 Host Adapter

(The logical block address must also be specified for reads and writes following a seek.) Upon initiation of the seek, controller ready and drive ready status bits