• Keine Ergebnisse gefunden

Temperatur [°C]11/3 Accident2/8 Installment coolers

N/A
N/A
Protected

Academic year: 2022

Aktie "Temperatur [°C]11/3 Accident2/8 Installment coolers"

Copied!
20
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)
(2)

Aspects of Modeling a Spent Fuel Pool

M. Loeffler, M. Braun AREVA GmbH

EMUG-Meeting, KTH Stockholm, Sweden, May 2 - 3, 2013

(3)

Content

1. Hydraulic diameter of a fuel assembly

2. Evaporation of a spent fuel pool

3. Transition between different CVs inside the SFP

(4)

1.) Hydraulic diameter of a fuel assembly

Convection driven by stack-effect inside fuel assembly (FA)

Water flow: Reynolds number ~1000 more laminar flow Air flow: Reynolds number ~1-10 only laminar flow

Flow limited by wall friction inside fuel assembly

MELCOR

FLnnn03 FRICFO FRICRO is unimportant FLnnnSk SAREA SLEN SHYD dominates

dz z T g

z z

T g

p

top

bottom

z

z bottom

top

stack

=

∆ ρ ( ( 0 )) ( ) ρ ( ( ))

A m d

p L

FA FA

FA

friction ⋅ &

⋅ ⋅

= ⋅

2

2 64

ρ µ

(5)

1.) Hydraulic diameter of a fuel assembly

MELCOR 1.8.6 notation:

FLnnn03 FRICFO FRICRO

FLnnnSk SAREA SLEN SHYD SRGH SLAM

S S S

S S

S S j

j j

f

j v v

D L v f

v K

P , , , , 2 , , , ,

2 1

ϕ ϕ ϕ ϕ

ϕ ϕ ϕ

ϕ = ρ + ∑ ρ

Re 0 .

= 16 f

Single-Phase Friction Factor (SLAM = 16.0 for tubes)

Laminar flow

coefficient, control function possible:

According our

experience for FAs in SFP not

necessary

Conventional definition of hydraulic diameter (for tube like geometries)

perimeter wetted

D S = 4 ⋅ area

RCLAD PITCH

D S = 2 ⋅ − 2 ⋅

(6)

1.) Hydraulic diameter of a fuel assembly

CFD-Analysis to determine hydraulic diameter (SLAM = 16.0)

Cross section of a complete BWR fuel assembly Rod bundle

Grid spacer

SHYD 38 % of Bundle-SHYD Fuel guard

SHYD Spacer-SHYD

Spacer with part of fuel rods (water channel and canister faded-out)

RCLAD PITCH

perimeter wetted

area > > ⋅ − ⋅

⋅ 2 2

4 SHYD

(7)

1.) Hydraulic diameter of a fuel assembly

Air-coolability of FA after dryout of the SFP

(8)

Content

1. Hydraulic diameter of a fuel assembly

2. Evaporation of a spent fuel pool

3. Transition between different CVs inside the SFP

(9)

2.) Evaporation of a spent fuel pool

SFP temperature of Fukushima Unit 4

20 30 40 50 60 70 80 90 100

T e m p e ra tu r C ]

Measurement Fit

1 1 /3 A c c id e n t

active cooling Evaporation cooling

2 /8 I n s ta ll m e n t c o o le rs

85-90 °C

(10)

2.) Evaporation of a spent fuel pool

Why does Fuel Pool not boil?

Low total decay power (1.58 MW @ 6/1/2011) Large water surface (11 m x 12 m)

Evaporation from sub-cooled water surface sufficient to cool pool

SFP 1F4, TEPCO 6/29/2011

Absence of

boiling

(11)

2.) Evaporation of a spent fuel pool

Problem – Weak experimental basis

Small scale experiments Boelter, Gordon, Griffin

Free Evaporation into Air of Water from a Free Horizontal Quiet Surface, Ind. Eng. Chem. 38 (1946) 596–600 Low temperature observations Z. Li, P. Heiselberg,

CFD Simulations for Water

Evaporation and Airflow Movement

in Swimming Baths, April 2005,

ISSN 1395-7953 R0503)

(12)

2.) Evaporation of a spent fuel pool

Evaporation of water is driven by diffusion (fast) Wet hot gas layer forms above water pool

Convection transports vapor away from water-gas-interface (slow)

Li et al.

Water / Pool

(13)

2.) Evaporation of a spent fuel pool

MELCOR Model of the SFP must….

… Allow the formation of wet surface layer

... Allow a convective heat transport into service floor

… Must not overestimate the convection flow

Service Floor

CVH - pool

FL-section area 0.5 m x SFP-diameter

FL-section area of 0.5 x

SFP area

(14)

2.) Evaporation of a spent fuel pool

MELCOR Model of the SFP must….

… Allow the formation of wet surface layer

... Allow a convective heat transport into service floor

… Must not overestimate the convection flow

Service Floor

CVH - left pool CVH - right pool FL with 0.5 m

height for gas

FL with height equals SFP depth - 0.5 m

for pool

(15)

2.) Evaporation of a spent fuel pool

Resulting evaporation rates in comparison to literature

(16)

Content

1. Hydraulic diameter of a fuel assembly

2. Evaporation of a spent fuel pool

3. Transition between different CVs inside the SFP

(17)

3.) Transition between different CVs inside the SFP

Problems when SFP is axially separated in different CVH

No evaporation when LIQLEV equals to a CVH boundary Only known fix: Do not axially split SFP

Convection No Convection Convection

LIQLEV

CV002 CV002 CV002

Service Floor Service Floor Service Floor

(18)

Conclusions

Hydraulic diameter of a fuel assembly

For small Reynolds numbers hydraulic diameter is very important for accurate pressure losses

Determination of hydraulic diameter is not straight forward

Whole range of Reynolds numbers can be satisfactory modeled with appropriate combination of Loss Coefficients and Hydraulic Diameters

Evaporation of a spent fuel pool

The convection from a layer above the in the spent fuel pool to the service floor limits the evaporation

0.5 m layer thickness seams to be reasonable

Transition between different CVs inside the SFP

Horizontal separation of a spent fuel pool is challenging if the level drops

We recommend no horizontal sub-division

(19)

End of presentation: Aspects of Modeling a Spent Fuel Pool

M. Loeffler, M. Braun AREVA GmbH

EMUG-Meeting, KTH Stockholm, Sweden, May 2 - 3, 2013

THANK YOU

THANK YOU

THANK YOU

THANK YOU

(20)

Any reproduction, alteration or transmission of this document or its content to any third party or its publication, in whole or in part, are specifically prohibited, unless AREVA has provided its prior written consent.

This document and any information it contains shall not be used for any other purpose than the one for which they were provided.

Legal action may be taken against any infringer and/or any person

breaching the aforementioned obligations.

Referenzen

ÄHNLICHE DOKUMENTE

Values for j e acquired along this route from all simulations were plotted over T IP in Fig. It determines not only the heat flux ˙ q as a result of the established

The evaporation of LaCl 3 , LaBr 3 and LaI 3 was investigated in closed tubes under argon atmosphere and correlated with data in

The results show that the mixing contributions of river discharge and evaporation are almost equal, although the freshwater transport due to evaporation is about one order

on assemblies of one-patch particles, there is no report about cluster assembly through emulsion droplet evaporation of colloidal particles with such anisotropic

From the measured uorescence proles extracted from the LIF images (Sec. 8.2.2 ), concentration depth proles [I − ](z) were determined to estimate the boundary layer thickness and

Factors affecting the oxygen isotopic composition of the Black Sea.. Murray (eds.): Black

Sta- bility effects are included only by a coarse approach using bulk transfer coefficients for evaporation of 0.0012 for stable, 0.0013 for neutral to slightly

• Particles starting at v < v 0 (not too close to i − ): Finally, something remarkable happens: after a reflection in region I they enter region III by crossing the ingoing