• Keine Ergebnisse gefunden

Core, section, and sample designation of the Ocean Drilling Program (ODP)

N/A
N/A
Protected

Academic year: 2022

Aktie "Core, section, and sample designation of the Ocean Drilling Program (ODP)"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

ODP identifies cores, sections and samples by a sequence of numerals:

Core: leg number + site number + hole letter + core number + core-type letter.

Example: Core 101-626A-2R

Section: leg number + site number + hole letter + core number + core-type letter + section number.

Example: Section 101-626A-2R-1

Core catcher: leg number + site number + hole letter + core number + core-type letter + core-catcher abbreviation.

Example: Sample 101-626A-2R-CC

Sample: leg number + site number + hole letter + core number + core-type letter + section number + interval from top of section in cm.

Example: Sample 101-626A-2R-1, 50-52 cm

In tables sample designation occur without identifier and unit.

Example:

113-693A-4R-3,23-25

This standard ODP sample designation should accompany each record or data file !

Core-type letters used: R = rotary core barrel (RCB); X = extended core barrel (XCB);

H = hydraulic piston corer (HPC), also advanced piston corer (APC);

B = drill-bit recovery; C = center-bit recovery; I = in-situ water sample;

S = sidewall sample; W = wash-core recovery; V = vibrapercussive corer (VPC)

M = miscellaneous material

Core, section, and sample designation of the Ocean Drilling Program (ODP)

Reference: ODP (1992) Instructions for contributors

Referenzen

ÄHNLICHE DOKUMENTE

Temperature- corrected predictions and temperature-corrected experimental re- sults for the variation of V p with depth for carbonate sediments of Site 709 are shown in Figure 3 (V p

On the other hand, burrowed sands and silty muds were deposited during cold times (heavy 5 18 0.. Depths and ages of stage boundaries as well as sedimentation rates of Hole

127-126 CTDO Processor: "ctdoxy sensor malfunctioning, +0.25 ml/l compared to one bottle/okay compared to other bottles; bottles okay vs upcast, ctdoxy rises not seen in

DS despiked salinity, changed temperature and/or conductivity - see .ctd file codes EB used nearby bottles and/or casts to estimate bottle oxygen value for ctdoxy fit NA no

Potential temperature, salinity, and sigma theta versus pressure for the upper 1500 db and potential temperature versus salinity for all cast data are plotted from the 2 decibar

I think CTD data from Syoyo-1994 were useful to depict the water mass structure only down to the intermediate depths because Dr, Yoritaka told me that they could not carried out

Its procedure is explained in the section of salinity measurements (Sec.2.1), and the results are included in Table 2.1.4. Our silicate and nitrate concentrations are ca. 2% lower

The data were first-differenced, lag corrected, pressure sorted and centered into 2 decibar bins for final data quality control and analysis, including fitting to water sample