• Keine Ergebnisse gefunden

Erratum to The influence of zero value subtraction on the performance of a new laser fluorescence device for approximal caries detection

N/A
N/A
Protected

Academic year: 2022

Aktie "Erratum to The influence of zero value subtraction on the performance of a new laser fluorescence device for approximal caries detection"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

source: https://doi.org/10.7892/boris.117757 | downloaded: 31.1.2022

ERRATUM

The influence of zero value subtraction on the performance of a new laser fluorescence device for approximal caries detection

Jonas A. Rodrigues

&

Isabel Hug

&

Adrian Lussi

Published online: 7 August 2008

#Springer-Verlag London Ltd 2008

Erratum to: Lasers Med Sci

DOI 10.1007/s10103-008/-0549-z

The first author’s citation was rendered wrongly. The correct citation is J. A. Rodrigues.

Lasers Med Sci (2009) 24:463 DOI 10.1007/s10103-008-0602-y

The online version of the original article can be found at http://dx.doi.

org/10.1007/s10103-008/-0549-z J. A. Rodrigues (*)

:

I. Hug

:

A. Lussi

Department of Preventive Restorative and Pediatric Dentistry, School of Dental Medicine, University of Bern,

Freiburgstrasse 7,

CH 3010 Bern, Switzerland e-mail: jorodrigues@hotmail.com

Referenzen

ÄHNLICHE DOKUMENTE

Our investigations of the infl uence of IA are based on the direct comparison of the reference with the TLS-distance. 1: Measurement setup a) for close range, b) for longer

Specifically, we investigate the change in MD&A and risk factor disclosures conditional on BlackRock ownership and observe similar changes in disclosure similarity for

[45] measured the laser-induced optical breakdown spectra in laser generated carbon plasma, using an Nd:YAG laser at its fundamental wavelength with high laser intensities

socialization factors [21], evolutionary theories [23] and use of different strategies. In the following we discuss some of these theories. Different levels of

Excitation spectra were acquired by fixing the emission wavelength (usually at the fluorescence emission maximum) and recording emission intensities while stepping through a

General findings were that (except for the magnesium deficient senescent maize leaves), i) both fluorescence ratios blue/red F440/F690 and blue/far-red F440/F740 strongly decreased

As indicated for all different spot size cases the deviation between the total removed mass and the removed mass by evaporation and phase explosion becomes smaller as the peak

Chlorella vulgaris, Chlorophyll Fluorescence Quenching, Green Algae, Molecular Oxygen Molecular oxygen can act as a collisional quencher of the singlet excited state of chloro-