C O R R E S P O N D E N C E

A fractured nasopharyngeal swab in the duodenum of a toddler:

an unusual complication of preoperative COVID-19 testing

Murat Tu¨mer, MD .Burak Ardıc¸lı, MD

Received: 16 March 2021 / Revised: 25 March 2021 / Accepted: 31 March 2021 / Published online: 20 April 2021 Canadian Anesthesiologists’ Society 2021

To the Editor,

The first COVID-19 case in Turkey was reported in March 2020 and approximately 35 million diagnostic tests have been performed since then.1All patients scheduled for elective surgery are recommended to undergo COVID-19 testing before their procedures.2We report on a case of an inadvertent fracture of a nasopharyngeal swab (NPS) in a toddler as an unusual complication of preoperative COVID-19 testing. The legal guardians of the patient provided written consent for this report.

A 22-month-old female patient was scheduled for neuroblastoma excision. According to our hospital policy, a COVID-19 swab test was performed preoperatively.

During the test, the NPS (Bio-Speedy COVID-19 RT- qPCR Detection Kit; Bioeksen, Istanbul, Turkey) fractured because the patient moved suddenly, resulting in the lodgement of approximately 5 cm of the swab stick in the nasopharynx. The piece could not be visualized with plain sight or onx-ray, and there was no clinical deterioration related to aspiration into the upper airways, for which there was no evidence on chestx-ray(Figure1, panel A). Since the patient exhibited no signs of intestinal obstruction and her surgical intervention was scheduled to be performed

within a few days, an exploratory upper gastrointestinal tract endoscopy was planned for the same session. An esophagogastroduodenoscopy procedure was performed after anesthetic induction followed by endotracheal intubation with an uncuffed tube (internal diameter, 4.5 mm). The NPS fragment was identified in the duodenum and gently retrieved with alligator endoscopic forceps (Figure, panel B; eVideo in the Electronic Supplementary Material). There was no mucosal injury. The scheduled surgical procedure was performed subsequently; after approximately six hours of surgery, the patient was extubated and transferred to the intensive care unit.

As NPS tests, which have been used for the diagnosis of viral infections for a long time, have become widely used in the COVID-19 pandemic, some complications related to their use have been reported, including accidental fracture in adults.3,4 We are unaware of reports of serious complications, and NPSs are still considered to be safe.

Our institution uses the same COVID-19 RT-qPCR Detection Kit in both pediatric and adult patients. Since pediatric patients may not cooperate and often move during the test as did our patient, healthcare providers should be experienced and trained to hold infants and children securely during these sample collection procedures. Alternative COVID-19 diagnostic test modalities such as saliva and nasopharyngeal aspirates may be considered5; however, saliva or saline swish and gargle samples are not suitable for patients under five years of age because of cooperation difficulties. Nasopharyngeal aspirates are also not recommended because of increased risk of COVID-19 transmission.

Supplementary Information The online version contains supplementary material available athttps://doi.org/10.1007/s12630- 021-01995-3.

M. Tu¨mer, MD (&)

Department of Anesthesiology and Reanimation, Faculty of Medicine, Hacettepe University, Ankara, Turkey

e-mail: m.tumer@hacettepe.edu.tr B. Ardıc¸lı, MD

Department of Pediatric Surgery, Faculty of Medicine, Hacettepe University, Ankara, Turkey

123

Can J Anesth/J Can Anesth (2021) 68:1450–1451 https://doi.org/10.1007/s12630-021-01995-3

(2)

Disclosures None.

Funding statement None.

Editorial responsibility This submission was handled by Dr.

Stephan K.W. Schwarz, Editor-in-Chief, Canadian Journal of Anesthesia/Journal canadien d’anesthe´sie.

References

1.Turkish Government Ministry of Health. Genel Koronaviru¨s Tablosu. Available from URL: https://covid19.saglik.gov.tr/TR- 66935/genel-koronavirus-tablosu.html(accessed April 2021).

2. American Society of Anesthesiologists.ASA and APSF statement on Perioperative Testing for the COVID-19 Virus. Available from URL: https://www.asahq.org/about-asa/newsroom/news-releases/

2020/12/asa-and-apsf-statement-on-perioperative-testing-for-the- covid-19-virus(accessed April 2021).

3. Medas R,Coelho R,Macedo G. An unusual collateral damage of COVID-19 pandemic. Gastrointest Endosc 2020; 92: 1261-2.

4. De Luca L, Maltoni S. Is naso-pharyngeal swab always safe for SARS-CoV-2 testing? An unusual, accidental foreign body swallowing. Clin J Gastroenterol 2021; 14: 44-7.

5. Czumbel LM,Kiss S,Farkas N, et al. Saliva as a candidate for COVID-19 diagnostic testing: a meta-analysis. Front Med (Lausanne) 2020; DOI:https://doi.org/10.3389/fmed.2020.00465.

Publisher’s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

FIGURE 1 Panel A) No fractured nasopharyngeal swab (NPS) was visible in daily preoperativex-raysof the patient taken after the test. Panel B) Fractured NPS piece identified in the duodenum via esophagogastroduodenoscopy (left) and following uneventful retrieval (right)

123

A fractured nasopharyngeal swab in the duodenum… 1451

Referenzen

ÄHNLICHE DOKUMENTE

A report based on the High Level Retreat of the African Union Panel of the Wise on Strengthening Relations with Similar Regional Mechanisms, held in

A smoothed particle hydrodynamics model for droplet and film flow on smooth and rough fracture surfaces, Advances in Water Resources 59: 1–14..

The preoperative urine osmolality and the urine specific weight values confirmed that patients with high urine creatinine had more intense renal water conservation before surgery

The objective of the present work is to study the effects of the carbonated smart water (CSMWI) injection on the naturally fractured carbonate reservoirs regarding the oil

The novelty of this study can be summarized as: (1) a new stress-induced aperture modeling that allows aperture (therefore fracture permeability) to vary along (curved) fractures, (2)

Posttraumatic diaphyseal malunion of the radius and the ulna can cause limited forearm range of motion (ROM) in pronation-supination, a painful distal radioulnar joint (DRUJ),

Please check the official homepage of the country of entry, which test (rapid antigen test or PCR) is valid and for how long test is valid..  Some countries accept a printout of

CUSTOM PAPER PAPER NO.1 - 10 You can select a number (between 1 to 10) to register the settings (such as Paper Type, Platen Gap, Thickness Pattern, Paper Feed Adjust, Drying