(1)

Feature Benefit

Autoloading for all reel sizes Reads all half-inch tape sizes IBM and ANSI compatible tape formats Meets data interchange standards

All-metal construction Rugged, rigid tape path

Brushless DC motors Exceptional reliability

Low profile - 5.25 inches high Conserves rack space

Self-calibrating - no electrical adjustments Easy installation

Extensive diagnostics, self-test capabilities Reduces service calls and downtime

Qualstar brings the power and reliability of 9-track tape technology to personal computers, worksta- tions, and midrange systems, providing easy interchange of ANSI or IBM mainframe data. The 3400 Series provides streaming tape performance in a low-profile, 5.25” high package. It will read and write mainframe information in ASCII or EBCDIC formats using labeled or unlabeled tapes with fixed or variable length records on DOS, NetWare, UNIX, Windows, OS/2, NT, VMS, or MAC O/S. Supported platforms include IBM PC, Macintosh, RS/6000, AS/400, Sun, DEC, HP 9000, Data General, SGI, Unisys and others.

The 3400 Series offers the industry’s broadest range of models and features to meet any require- ment. A comprehensive set of diagnostic tools is built into each drive, including automatic calibration self test maintenance reminders, and performance monitoring functions. The digital display gives clear concise reporting of all drive functions and diagnostics. Its advanced features, compact size and rugged all-metal construction make Qualstar’s 3400 Series the tape drive of choice for critical applications worldwide.

T h e Ta p e E x p e r t s

3400 Series

9-Track Tape Drives

®

Seismic

Proven

(2)

Feature/Model PE Quad* GCR 2-Speed GCR

Pertec Interface 3404 3412 3414 3418

SCSI-2 Single Ended 3404S 3412S 3414S 3418S

SCSI-2 Differential 3404SD 3412SD 3414SD 3418SD

Density 1600/3200 Quad 1600/6250 Quad

IPS/KBS @ 800 NRZI N/A 62/100 N/A 62/100

IPS/KBS @ 1600 PE 125/200 125/200 125/200 125/200

IPS/KBS @ 3200 DPE 62/200 62/200 N/A 62/200

IPS/KBS @ 6250 GCR N/A 125/781 62/390 62/390, 125/781

Rewind (max.) 400 IPS 400 IPS 400 IPS 400 IPS

*Quad Density is 6250/3200/1600/800 BPI. 800 BPI is read only.

Available from:

Founded in 1983, Qualstar has delivered over 25,000 reliable, cost-effective tape systems.

Our tape products are sold worldwide through a network of knowledgeable dealers and integrators who share our commitment to quality.

T h e Ta p e E x p e r t s

®

QUALSTAR CORPORATION 6709 Independence Avenue Canoga Park, CA 91303 Fax: (818) 592-0116 Tel: (818) 592-0061 (800) 468-0680 E-mail: sales@qualstar.com Web: www.qualstar.com

Qualstar Corporation does not warrant the MTBF to be representative of any particular unit installed for customer use. Failure rates are derived from a large database of test samples. The individual failure rate will vary from unit to unit.

All information and specifications are based on our knowledge of the products at the time this data sheet was printed. We believe this information to be correct, however, Qualstar reserves the right to change specifications without notice.

Qualstar and the Qualstar logo are registered trademarks of Qualstar Corporation.

Trademarks are the property of their respective owners.

Copyright © 1997 Qualstar Corporation.

All rights reserved. DS 234 7/97

*

1.0 MB Cache Buffer, 4 MB/sec Burst

Supports Synchronous Data Transfer

User Configurable

Optional Internal Termination

Remote Density Selection SCSI-2 Interface

Rack Mount

Host Adapter

Cables

Software

Extended Warranty Options

Width (in./cm): 19.00/48.26

Height (in./cm): 5.25/13.34

Depth (in./cm): 25.20/64.01

Weight (lb./kg): 58/26

Voltage: 100, 120, 220, 240 VAC

Frequency: 48 - 62 Hz

Watts: 200

MTBF: 24,000 Hours*

Warranty: 1 Year Advance Replacement Specifications

Referenzen

ÄHNLICHE DOKUMENTE

Place the main program in the reader, depress the tape feed switch to clear the end-of-tape flag, and type the command string.. If the loader is not satisfied

This means that an exception record is recognized when the character in the first exception- character location in the input data record matches the exception character

For TAPE files. INPUT or OUTPUT must be specified since these parameters are decisive for correct compilation. An error here ruins the whole DTF. These two

The tape unit remains in backward status, unless reset by 'set read status' or 'set write status.' Since tape can only be written forward, 'backward' sets 'read status' in the

The sense operation causes the transfer of the sense data from the selected tape unit and from the tape control unit to main storage. The data is placed in

Sense Bit 1 (Intervention Required): Indicates that the 2671 became not-ready before the normal completion of a read operation (for example, overstep on a tape stop because of

installation requirements associated with the tape transport when installed in the pooler configuration'. In the pooler configuration, the tape transport is

The tape unit is comprised of seven major functional areas: the operator panel, the tape unit control logic, the data handling electronics, the capstan servo