Improving patient safety by doing less rather than more:

many peripheral intravenous catheters are unnecessary

Diana

Egerton-Warburton

1,2

Simon Craig

1,2

Rhonda Stuart

2,3

Claire Dendle

2,3

1 Emergency Department, Monash Medical Centre, Monash Health, Melbourne, Victoria, Australia

2 Department of Medicine, Southern Clinical School, Monash University,

Melbourne, Victoria, Australia 3 Monash Infectious Diseases, Monash Health, Melbourne, Victoria, Australia

Letter

Reply to: Improving patient safety during insertion of peripheral venous catheters:

an observational intervention study. GMS Hyg Infect Control. 2013; 8(2):Doc18

We would like to congratulate Kampf and colleagues on their study, which demonstrates the effectiveness of a multimodal intervention to improve safety for the insertion of peripheral intravenous catheters (PIVC) [1].

The issue of nosocomial infection is a small but real risk associated with the insertion of PIVC [2]. While we support and agree with the approach of the authors, we feel they may have missed an important initial step – ensuring that the PIVC is needed in the first place.

We performed a study in our institution that demonstrated that 50% of PIVC inserted in adult patients in our emer- gency department were unused [3]. Of those subsequently admitted to hospital, a similar proportion still had an un- used PIVC at 72 hours. While some of these unused PIVC may have still been appropriate, it is likely to be a small minority. We described this situation as “pain without gain”.

The safest, least painful and least costly peripheral ven- ous catheter is one that was never inserted in the first place.

We would encourage vigilance by health professionals for all aspects of PIVC. This should include monitoring of usage rates and ensuring that they are only inserted if there is a reasonable likelihood of being used.

Notes

Competing interests

The authors declare that they have no competing in- terests.

Reply

Please read the reply to this letter: [4].

References

1. Kampf G, Reise G, James C, Gittelbauer K, Gosch J, Alpers B.

Improving patient safety during insertion of peripheral venous catheters: an observational intervention study. GMS Hyg Infect Control. 2013;8(2):Doc18. DOI: 10.3205/dgkh000218 2. Stuart RL, Cameron DR, Scott C, Kotsanas D, Grayson ML,

Korman TM, Gillespie EE, Johnson PD. Peripheral intravenous catheter-associated Staphylococcus aureus bacteraemia: more than 5 years of prospective data from two tertiary health services.

Med J Aust. 2013 Jun;198(10):551-3. DOI:

10.5694/mja12.11699

1/2 GMS Hygiene and Infection Control 2014, Vol. 9(1), ISSN 2196-5226

Letter to the Editor

OPEN ACCESS

(2)

3. Limm EI, Fang X, Dendle C, Stuart RL, Egerton Warburton D. Half of all peripheral intravenous lines in an Australian tertiary emergency department are unused: pain with no gain? Ann Emerg Med. 2013 Nov;62(5):521-5. DOI:

10.1016/j.annemergmed.2013.02.022

4. Kampf G, Reise G, James C, Gittelbauer K, Gosch J, Alpers B. We agree: the less insertions, the better. GMS Hyg Infect Control.

2014;9(1):Doc02. DOI: 10.3205/dgkh000222

Corresponding author:

Dr. Simon Craig

Emergency Department, Monash Medical Centre, 246 Clayton Rd, Clayton, Victoria, Australia, 3168

Simon.craig@monashhealth.org

Please cite as

Egerton-Warburton D, Craig S, Stuart R, Dendle C. Improving patient safety by doing less rather than more: many peripheral intravenous catheters are unnecessary. GMS Hyg Infect Control. 2014;9(1):Doc03.

DOI: 10.3205/dgkh000223, URN: urn:nbn:de:0183-dgkh0002235

This article is freely available from

http://www.egms.de/en/journals/dgkh/2014-9/dgkh000223.shtml Published:2014-03-07

Copyright

©2014 Egerton-Warburton et al. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.en). You are free: to Share — to copy, distribute and transmit the work, provided the original author and source are credited.

2/2 GMS Hygiene and Infection Control 2014, Vol. 9(1), ISSN 2196-5226

Egerton-Warburton et al.: Improving patient safety by doing less rather than ...

Referenzen

ÄHNLICHE DOKUMENTE

[Water remaining in the root zone of soils can be brought back up to the surface through evapotranspiration, the water goes into the atmosphere from evaporation and transpiration,

The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment,

Irrespective whether nanofi ltration or reverse osmosis membranes were used, the same feed spacer channel pressure drop increase and biomass concentrations were observed (Figure

Aside from conventional unit operations and processes present at wastewater treatment facilities that often allow residual pharmaceuticals to pass through,

Table 9.1 Compilation of ozone rate constants and singlet oxygen yields in percentage of ozone consumption (Muñoz et al., 2001) of some organic sulfur-containing compounds..

Her teaching and research focuses on computational methods, aspects of flood modeling and vulnerability related to floods, lake and reservoir modeling, river systems and water

Therefore, before costing an improved drinking-water supply technology, the quality of the water at the source must be assessed and, if necessary, appropriate water treatment must

This proposal addresses these critical issues by focusing on methods for concentrating pathogens from large volumes of water and extracting high quality nucleic acids so that the