• Keine Ergebnisse gefunden

Time-resolved x-ray emission from laser-produced plasmas with timing fiducial

N/A
N/A
Protected

Academic year: 2022

Aktie "Time-resolved x-ray emission from laser-produced plasmas with timing fiducial"

Copied!
4
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

source: https://doi.org/10.7892/boris.115465 | downloaded: 1.2.2022

Laser and Particle Beams (1986), vol. 4, parts 3 * 4 , pp. 495-498 495 Printed in Northern Ireland

Time-resolved x-ray emission from laser-produced plasmas with timing fiducial

ByW. LAMPART AND J. E. BALMER

Institute of Applied Physics, University of Berne, Sidlerstrasse 15, CH3012 Berne, Switzerland (Received 3 February 1986)

High-temperature plasmas were produced by focusing 1-05 jum, lOOpsec laser pulses onto Al layer targets at a mean irradiation of 3-1013 Watt/cm2. By means of simultaneous measurements of the thermal x-ray emission and the frequency- quadrupled laser pulse we observe a 20 ± 15 psec delay of the x-ray peak relative to the peak of the incident laser pulse. In addition, modulations on the trailing edge of the driving pulse appear strongly enhanced in the x-ray signature.

Measurements of the temporal evolution of the x-ray emission with a precise temporal reference to the driving pulse are of fundamental significance for laser fusion and x-ray laser research. The x-ray spectral signatures provide information about the nature of the laser light absorption and the transport of energy between different regions of the ablating plasma. To obtain such data optical and x-ray signals have to be recorded at the same time. Simultaneous measurements of the hard x-ray emission (/iv>30keV) and the incident 1-06 jum laser pulse using the SI cathode of an optical streak camera have been reported recently (Lerche & Phillips 1981). Corresponding measurements of the soft x-radiation, however, require different photocathodes for the two spectral regions. In one experiment the x-ray emission and the 0-35 jum laser light specularly reflected from the plasma were recorded with a hybrid photocathode (Marjoribanks et al. 1982). The reliability of the timing fiducial derived from the temporally varying reflective properties of an expanding laser-driven plasma may, however, be questioned. In another experiment the x-ray emission and the 1-05 fim laser pulse were recorded with separate streak cameras driven by a common ramp generator (Balmer et al. 1985).

In this letter we report an alternative approach. The soft x-ray emission from plasmas produced by 1-05 /xm laser light and a frequency-quadrupled fraction of the laser pulse were simultaneously recorded with a single streak camera equipped with a specially designed hybrid cathode. The UV fiducial was introduced onto the photo- cathode along a separate path and thus represents a reliable reference for relating the x-ray signature to the peak of the driving pulse.

The experimental layout is shown in figure 1. The measurements were performed with 100 psec, 1-05 jum laser pulses, focused normally onto a 3000 A layer of Al coated on a thick perspex slab target. The mean irradiation on target was about 3-1013Watt/

cm2 for an incident laser energy of typically 0-2 J. The x-ray streak camera was of a re-entrant design with the plane of the photocathode about 10 cm from the plasma.

The home-made cathode consisted of a 220 A layer of Au sputtered onto a 1 mm thick quartz substrate and a 1200 A layer of Csl evaporated onto a 14-5 jum thick Be foil. A 14-5 /im Be foil between the plasma and the cathode served to block scattered UV radiation from reaching the UV section of the cathode. In this configuration, either section was opaque to radiation of the other section. The x-ray emission recorded by

0263-0346/86/0404-0495S05.00

available at https:/www.cambridge.org/core/terms. https://doi.org/10.1017/S0263034600002160

Downloaded from https:/www.cambridge.org/core. University of Basel Library, on 30 May 2017 at 17:49:58, subject to the Cambridge Core terms of use,

(2)

496

A

./CrystalsDoubling

W. Lamport and J. E. Balmer

Quartz Lens

Target

Au/SiO

I-Streak Tube f / 3 L e n s

-—j—Csl/Be -*/•—Be-Foil

Streak Camera Q« Target

FIGURE 1. Experimental set-up.

-100 +100

Time (ps)

FIGURE 2. X-ray streak camera image of a temporally modulated laser pulse and microdensito- meter traces.

available at https:/www.cambridge.org/core/terms. https://doi.org/10.1017/S0263034600002160

Downloaded from https:/www.cambridge.org/core. University of Basel Library, on 30 May 2017 at 17:49:58, subject to the Cambridge Core terms of use,

(3)

Time-resolved X-ray emission from laser-produced plasmas 497 the streak camera was thus composed of Al line emission and continuum radiation with an energy cut-off of about 1-4 keV.

The relative timing of the two signals was calibrated by running the fourth harmonic of the 105 ^mNd: Glass laser along both beam paths onto a Au-on-Quartz cathode.

The quadrupling crystal was inserted in front of the beamsplitter, the focusing lens and the IR turning mirrors were removed and replaced by a quartz lens and Al mirrors, respectively. A UV turning mirror was installed at the exact position of the target.

These changes in optical path length were taken into account for the absolute UV calibration. We found that the plasma x-ray history could be measured to within 15psec relative to the peak of the driving pulse. The largest individual error was

±10psec and resulted from the UV calibration, although the two beam paths were adjusted to minimize errors due to nonlinearities of the sweep speed and distortion of the intensifier. The measured sweep rate on the phosphor of the intensifier (Mullard 50/40) was 52 psec/mm with a linearity of better than 10%.

The streak data was recorded on calibrated Kodak Royal-X Pan film and analyzed

-100 +100

Time (ps)

FIGURE 3. X-ray streak camera image and microdensitometer traces.

available at https:/www.cambridge.org/core/terms. https://doi.org/10.1017/S0263034600002160

Downloaded from https:/www.cambridge.org/core. University of Basel Library, on 30 May 2017 at 17:49:58, subject to the Cambridge Core terms of use,

(4)

498 W. Lamport and J. E. Balmer

on a microdensitometer. The temporal evolution of the thermal x-ray emission, together with the UV fiducial signal is shown in figure 2. The zero on the time scale corresponds to the peak of the incident laser pulse. It can be seen that the x-ray emission peaks approximately 20 ± 15 psec after the peak of the UV pulse and exhibits a low-intensity tail below about 2% of the x-ray peak intensity. This loss of temporal resolution in the low-intensity regime has been observed by other workers and was attributed to late-time emission (straggling) of slow electrons from Csl (Stradling el al.

1980).

An additional result obtained from these measurements is shown in figure 3. A slight misalignment of the mode-locked oscillator cavity occasionally produced modulated or even multiple pulses. The 4<w fiducial in the lower part of figure 3 shows such a situation where the main pulse is followed by a weaker post-pulse after about 170 psec.

As can be seen in the upper part of the figure this post-pulse, although much weaker, gives rise to a strongly enhanced emission in the soft x-ray spectral region. This is most likely due to the higher absorption efficiency experienced by the second peak as a result of the increasing scale length of the expanding plasma. The enormous impact of a temporal modulation of the laser pulse on the history of the x-ray emission suggests that great care has to be taken when relating the 'peak' of an observed x-ray signal to the 'peak' of the irradiating pulse. Therefore in discussing x-ray emission from laser-produced plasmas precise information on the temporal profile of the driving laser pulse becomes indispensable.

In conclusion, we have demonstrated the feasibility of synchronously recording the soft x-ray emission and a UV timing fiducial with a hybrid photocathode. We used this experimental arrangement to demonstrate that the thermal x-radiation from an Al plasma peaks 20 ± 15 psec after the peak of the incident 100 ps laser pulse.

REFERENCES

BALMER, J. E., LAMPART, W., ROSCHGER, E., HARES, J. D. & KILKENNY, J. D. 1985 Rev. Sci.

Instrum. 56, 860.

LERCHE, R. A. & PHILLIPS, G. E. 1981 Lawrence Livermore National Laboratory, Report No UCRL-86405-81.

MARJORIBANKS, R. S., RICHARDSON, M. C , DELETTREZ, J., LETZRING, S., SEKA W. &

VILLENEUVE, D. M. 1982 Opt. Commun. 44, 113.

STRADLING, G. L., MEDECKI, H., KAUFFMAN, R. L., ATTWOOD, D. T. & HENKE, B. L. 1980

Appl. Phys. Lett. 37, 782.

available at https:/www.cambridge.org/core/terms. https://doi.org/10.1017/S0263034600002160

Downloaded from https:/www.cambridge.org/core. University of Basel Library, on 30 May 2017 at 17:49:58, subject to the Cambridge Core terms of use,

Referenzen

ÄHNLICHE DOKUMENTE

Ever since the discovery of x rays in 1895 one was searching for ways to build an x-ray microscope similar to the ones available for visible light. The benefits of such an

Depending on the energy of ionized carriers, several secondary processes such as impact ionization, tun- nel ionization, free carrier diffusion, free carrier scattering on atoms

For our measurements, the LCLS was working with an electron bunch charge of 150 pC and beam energy of 4.8 GeV. The peak current after BC2 was about ~1 kA. The expected FEL pulse

Combining this mechanism with the process of Thomson scattering in which electrons transfer part of their energy to incident laser photons, results in a compact, high energy

To obtain a basis for the identification of the observed lines of highly ionized gallium, the transition energies in the range between 100 eV and 300 eV for different

It is shown that using optimized parameters of the undulator x-ray source, thereby controlling the number of the off-axis photons and minimizing the number of photons in the

A different bunch energy has an impact on the electron waist and divergence relation for constant emittance, but also on the Thomson radiation cone, as well as the chromatic focusing

By simultaneously probing the amplitude of the AFM Bragg peak and the shift of the structural Bragg peak after excitation, we are able to directly relate structural and