SCEA

SCSI Cluster ~xpansion Adapter

User's Manual

CMD Technology, Inc.

1 Vanderbilt Irvine, CA 92718 (714) 454-0800

MAN-002000-000 Rev. 1.4 December 1992

(2)
(3)

Copyright

Disclaimer

FCC Notice

Warranty

This manual is copyrighted and all rights are reserved. No portion of this document may be cop- ied, photocopied, reproduced, translated, or reduced to any electronic medium or machine read- able form without prior written consent from CMD Technology, Inc. (CMD).

CMD, CMD Technology, CSB-2000 and SCEA are all trademarks of CMD Technology, Inc. All other product and company names are trademarks and registered trademarks of other manufac- turers.

Copyright © CMD Technology, Inc. September 1991. All rights reserved.

CMD reserves the right to make changes to this manual and the equipment described herein with- out notice. CMD has made all reasonable efforts to insure that the information in this manual is accurate and complete. However, CMD shall not be liable for any technical or editorial errors or omissions made herein or for incidental, special, or consequential damage of whatsoever nature resulting from the furnishing of this manual, or operation and performance of equipment in con- nection with this manual.

Class A Computing Device:

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communica- tions. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

BASIC WARRANTY -In the absence of any optional warranty or continuing provisions by for- mal agreement, CMD warrants its products in accordance with the schedules listed below. Pur- chaser hereafter mentioned refers at all times to the customer who purchased CMD produd(s).

HOST ADAPTER WARRANTY - CMD warrants Host Adapter products of its manufacture to be free from defect in material and workmanship for a period of one year from the date of shipment.

During this period, if the customer experiences difficulties with a CMD Host Adapter and is un- able to resolve the problem via phone with CMD Technical Support, a Return Material Authoriza- tion (RMA) will be issued. Following receipt of an RMA, the Purchaser is responsible for return- ing the product to CMD, freight prepaid. CMD, upon verification of warranty, will repair or re- place at its option the Host Adapter in question, and will then return the product to the Pur- chaser, freight prepaid.

CABLE WARRANTY - All CMD provided cables are warranted for ninety (90) days from the time of shipment. Questionable cables should be returned to CMD, freight prepaid, where they will be repaired or replaced by CMD at its option and returned to the Purchaser, freight prepaid.

GENERAL TERMS - The above warranties shall not apply to expendable components such as fuses, bulbs, and the like, nor to connectors, adapters, and other items not a part of the basic prod- uct. CMD shall have no obligation to make repairs or to cause replacement required through nor- mal wear and tear or necessitated in whole or in part by catastrophe, fault or negligence of the user, improper or unauthorized use of the product, or use of the product in such a manner for which it was not designed, or by causes external to the product, such as, but not limited to, power failure or air conditioning. CMD's sole obligation hereunder shall be to repair or replace any defective product, and, unless stated, pay return transportation costs within the United States of America for such replacement. Purchaser shall provide labor for removal of the defective prod- uct, shipping charges for return to CMD and installation of its replacement. On-site services are not a part of this warranty. Above warranties are subject to change without notice.

RETURNED MATERIAL - Warranty claims must be received by CMD within the applicable war- ranty period. A replaced product, or part thereof, shall become the property of CMD and shall be returned to CMD at Purchaser's expense. All returned material must be accompanied by a Re- turn Materials Authorization (RMA) number assigned by CMD. For RMA numberS call CMD at (714) 454-0800.

THE EXPRESSED WARRANTIES SET FORTH IN THIS AGREEMENT ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION,

(4)

Return and

SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNEC- TION WITH THE USE OR PERFORMANCE OF THE PRODUCT.

Repair Policy WARRANTY PERIOD

The following warranty period is from the date of shipment:

CMD Host Adapter one year

Cable 90 days

Drive manufacturer's warranty

RETURN FOR CREDIT

The allowable period of return for credit from the date of shipment is as follows

CMD Host Adapter less than 30 days

Cable less than 30 days

Drive not applicable

RETURN FOR REPAIR CMD Host Adapter

In-Warranty (Less than 1 year)

• CMD offers a 15 working day turnaround repair service at the cost of parts only. Defective boards will be repaired and returned to the customer within 15 working days from the date of return to CMD.

• CMD also offers two in-warranty 24 hour expediting services:

24 Hour Turnaround Loaner Service:

Under this policy, CMD will ship a loaner in 24 hours during regular working days to the customer for a charge of $100.00 per loaner. Upon receiving the loaner, customer must re- turn the defective board to CMD within seven (7) days for repair. CMD will repair the de- fective board and return the board to the customer. Customer must then return the loaner in seven (7) days after the receipt of the repaired board. Approval for loaner service is based on credit verification.

24 Hour Turnaround Swap Service:

In the case that the defective board is within the first six (6) months of the warranty, CMD, at its own option, offers a 24 hour turnaround swap service. CMD will ship the same model of the board to customer within 24 hours during working days in exchange for the defective board. CMD will swap with a new board if board is not functional upon arrival.

For all other cases, swap will occur with either a new or refurbished board for a charge of

$200.00. CMD does not offer swap services for boards that are purchased more than six months from the date of shipment. Customer is responsible for returning the defective board to CMD within seven (7) days after receipt of the swapped board.

• The remaining warranty period shall apply to the repaired or swapped board.

Out-of-Warranty (more than 1 year)

• CMD offers a 15 working day turnaround repair service at a rate of $300.00 plus parts and freight for all out-of-warranty host adapter boards. Defective boards will be repaired and returned to customer within 15 working days starting with date of return to CMD.

• CMD also offers an Out-oj-Warranty 24 Hour Turnaround Loaner Service:

Under this policy, CMD will ship the same model loaner in the 24 hour time frame of work- ing days to customer for an additional charge of $100.00 plus freight per loaner. The loaner is for use by the customer during the period that the defective board is being repaired. Cus- tomer is responsible for returning the defective board to CMD within seven days after the receipt of loaner and returning the loaner in seven (7) days once the defective board is re- paired and received. The approval of the loaner service is at CMD's option and based upon customer credit verification.

• CMD will extend warranty for a period of six (6) months on any out of- warranty repaired board.

Cable

In-Warranty (90 days) - free swap.

Out-of-Warranty (90 days) - not applicable.

(5)

Drive

In-Warranty (per manufacturer) - manufacturer charge only.

Out-of-Warranty (per manufacturer) - manufacturer charge plus $100 CMD handling.

RETURN FOR UPGRADE/ UPDATE CMD Host Adapter

In-Warranty (less than 1 year)

• CMD offers a 15 working day turnaround different function upgrade service for boards that can be upgraded to a higher function; and a free 15 working day turnaround ECO Field Upgrade for all its boards. CMD will upgrade the hardware of its board to a higher function for a charge of the difference of list prices of the original and upgraded functions. CMD will also update its board to its latest firmware release at no charge to the customer. Boards will be upgraded/updated and returned to the customer within 15 working days from the date of return to CMD.

• CMD also offers 24 hour turnaround loaner service as stated in "RETURN FOR REP AIR./1

• The remaining warranty period shall apply to the updated board. For upgraded boards, CMD will extend warranty for a period of six months.

Out-of-Warranty (More than 1 year)

• CMD offers a 15 working day turnaround different function upgrade service for boards that can be upgraded to a higher function at a charge of the difference of list prices of two functions.

CMD also offers a free 15 working day turnaround ECO Field Upgrade for all its boards.

Boards will be upgraded/updated and returned to customer within 15 working days from the date of return to CMD.

• CMD also offers 24 hours turnaround Loaner Service as stated in "RETURN FOR REP AIR."

• There will be no warranty extension for same function firmware update. For different func- tion Hardware upgrade, CMD will extend warranty for a period of six (6) months.

Drive--same as in RETURN FOR REP AIR.

SHIPPING CHARGES

The following shipping charges apply to all REP AIR, SWAP, LOANER, and UPGRADE UNITS.

In-Warranty

• Domestic - freight from CMD to customer is to be paid by CMD; freight from customer to CMD is to be paid by customer.

• International- all fees are to be paid by customer (including custom duty and broker fees).

Out-of Warranty

• Domestic - all fees are to be paid by customer.

• International- all fees are to be paid by customer (including custom duty and broker fees).

GENERAL CONDITIONS

All goods returned to CMD including returns for credit, swap returns, loaner returns, and evalua- tion returns shall remain in good condition. Any damage or alteration done by the customer will result in a rejection or additional charge to the customer.

Customer must consult CMD Technical Support for authorization of CMD not functional upon arrival boards and swap requests. CMD Sales personnel must be consulted for authorization of returned goods for credit and/ or evaluation.

(6)
(7)

Preface

The SCEA Revision 1.4 is the fourth revision of the SCEA User's Manual. The following changes have been made to the SCEA User's Manual:

• Configuration information for DEC Alpha AXP systems has been added.

• The section on Multi-Hosting Configuration for VMS has been changed.

• An additional illustration in Chapter 4 shows a pin out diagram for the SCEA RS-232 port.

• The discussion of the SCEA On-Board Utility has been updated.

• Table C-3 has been updated to reflect a change in the position of the Wll-2 jumper.

Preface vii

(8)
(9)

Table of Contents

1

Introduction 1-1

How to Use this Manual 1-1

Conventions 1-2

2

Features and Components 2-1

Features 2-1

Removable Media 2-2

Platform Control 2-2

Multi-Hosting for VMS 2-3

SCSI Library Manager 2-3

SCEAModels 2-3

Components 2-4

LED Indicators 2-6

Specifications 2-7

SCSI Bus Cabling 2-7

Host SCSI Port 2-8

Host SCSI Port Termination 2-8

Device SCSI Port 2-8

Device SCSI Port Termination 2-9

3

Installation 3-1

Installing the SCEA into a Storage Box, Shoebox, or System 3-1 Installing the SCEA into a TRIMM SCEAbox Enclosure 3-11

4

Configuration 4-1

VMS, VAXstation Configuration 4-1

SunOS Configuration 4-4

ULTRIX, DEC station Configuration 4-7

AIX, IBM RISC System/6000 Configuration 4-10

Table of Contents ix

(10)

Creating a File System Mounting the File System

Adding a Disk After the SCEA is in the System CMD SCSI Interface Boards

On-Board Utility

Accessing the Utility Through the RS-232 Port

Displaying SCSI Device and Setting Up Configuration Testing SCSI Device

Sending SCSI Commands To The Device Formatting the Drive

Qualifying the Drive

Completing Utility Functions Multi-Hosting Configuration for VMS Appendices

A

Supported Devices and Operating Systems SCSI Devices

Magnetic disk drives

Erasable Optical disk drives

Erasable Optical disk cartridge manufacturers WORM drives

Tape drives

Jukeboxes (SCEA/J only) Operating Systems Supported

VAXstation 3100 Model 30, 38, 76 Sun SPARCstation and SPARCserver DECstation 5100

IBM RISC System/6000 SGI IRIS INDIGO

B

Troubleshooting

VMS Analyze/Error Utility Cables

LED Indicators

CMD Technical Support

4-18 4-21 4-22 4-23 4-24 4-24 4-25 4-27 4-28 4-29 4-29 4-30 4-30

A-1 A-I A-I A-2 A-2 A-2 A-2 A-2 A-3 A-3 A-3 A-3 A-3 A-3 8-1 B-1 B-2 B-2 B-2

(11)

C

Connectors and Jumper Settings Connectors

Jumper Settings

Glossary Index

C-1 C-l C-3

G-1 1-1

Table of Contents xi

(12)
(13)

List of Tables

2

Features and Components

2-1: Removable Media 2-2

2-2: Platform Control 2-2

2-3: SCEA Models 2-3

2-4: LED Indicators 2-6

2-5: Controller Specifications 2-7

3

Installation

3-1: Host SCSI Port ID 01) Jumper Selections 3-3

3-2: Device SCSI Port ID 0"2) Jumper Selections 3-7

4

Configuration

4-1: Mapping for Drives 4-3

4-2: Host SCSI Port (Jl) ID Jumper Selections 4-31 4-3: Device SCSI Port 02) ID Jumper Selections 4-31 Appendix

C

Connectors and Jumper Settings

C-l: Connectors C-l

C-2: Jl and J2 Connector Pin Assignments C-2

C-3: Jumper Settings C-3

C-4: Host SCSI Port 0"1) ID Jumper Selections C-3 C-5: Device SCSI Port 0"2) ID Jumper Selections C-4

C-6: Platform Control C-4

Ust of Tables xiii

(14)
(15)

List of Figures

2

Features and Components

2-1: SCEA SCSI ports 2-1

2-2: SCEA components 2-5

3

Installation

3-1: Shoebox installation example 3-2

3-2: SCSI ID configuration 3-3

3-3: Host SCSI port (Jl) cable connection 3-4

3-4: Shoebox or Storage Box Jl SCSI connection 3-5

3-5: Host SCSI port termination 3-6

3-6: Power connection 3-7

3-7: Device SCSI port (J2) cable connection 3-8

3-8: Cabling example from inside Subsystem 3-9

3-9: Device SCSI port termination 3-10

3-10: Connecting SCSI cables in the SCEAbox 3-12

3-11: Installing the SCEA into the SCEAbox 3-13

3-12: Device and Host ID selectors 3-13

4

Configuration

4-1: SCSI ID and LUN for VAXstation 4-4

4-2: SCSI ID and LUN for SPARCstation 4-6

4-3: SCSI ID and LUN for workstation 4-9

4-4: SCSI ID and LUN for workstation 4-10

4-5: System Management Menu 4-11

4-6: Fixed Disk Menu 4-11

4-7: Command Status Menu 4-12

4-8: Pysical and Logical Storage Menu 4-13

4-9: Logical Volume Manager Menu 4-13

List of Figures xv

(16)

4-12: Add a Volume Group, Menu 2 4-13: Command Status Menu

4-14: Add a Logical Volume, Menu 1 4-15: Add a Logical Volume, Menu 2 4-16: Command Status Menu

4-17: File Systems Menu

4-18: Add/Change/Show /Delete File Systems Menu 4-19: J ournaled File Systems Menu

4-20: Add a Journal File System Menu 4-21: Command Status Menu

4-22: Mount a File System Menu 4-23: Command Status Menu 4-24: SCEA RS-232 Port 4-25: RS-232 Cable Pin Out 4-26: SCEA Utility

4-27: Current configuration, default 4-28: Configuration change

4-29: Reconfigure Device

4-30: Example of Multi-Hosting Appendix

C

Connectors and Jumper Settings

Figure C-1: Nonshielded SCSI device connector Glossary

Index

4-15 4-16 4-16 4-17 4-18 4-18 4-19 4-19 4-20 4-20 4-21 4-22 4-24 4-24 4-25 4-26 4-26 4-27 4-32

C-1 G-1

1-1

(17)

1

Introduction

This User's Guide explains the basics of your SCEA TM. It includes information on setting up and configuring the system for use.

How to Use this Manual

This guide has four chapters, three appendices, a glossary, and an index. Each chapter explains a different aspect of preparing your SCEA for use. You may refer to the appendices for further configuration and troubleshooting

information. The following descriptions summarize each section.

Chapter 1: Introduction explains the purpose of this guide and details the conventions used.

Chapter 2: Features and Components describes the SCEA and details its distinct features and specifications.

Chapter 3: Installation describes installation procedures for the SCEA, SCSI devices, and termination of the SCSI bus.

Chapter 4: Configuration describes configuration of operating system

software for use with the SCEA, the On-Board Utility, and Multi-Hosting with VMS.

Appendix A: Supported Devices and Operating Systems lists the SCSI devices and operating systems compatible with the SCEA.

Appendix B: Troubleshooting gives some troubleshooting guidelines for the SCEA.

Introduction 1-1

(18)

Appendix C: Connectors and Jumper Settings lists all connectors and jumper settings for the SCEA.

Conventions

The following conventions are used in the SCEA User's Guide.

Keycaps-Characters in square brackets represent keys on your keyboard. For example, "Press [ENTER]" means press the [ENTER] key. When two or more keys are joined by a plus sign (+), press those keys at the same time.

Commands-Italics text represents a command that can be used on a system, such as show dev dk on the V AXstation 3100TM.

NOTE Sometimes italics will be used for emphasis where no action is necessary; for example, "do not remove jumper shunt W13."

Entering Text or Commands on Screen-Text or commands that must be entered on screen will be in italics and bold as show dev dk; be sure to enter the text or command and press [ENTER].

(19)

2

Features and Components

This chapter describes the SCEA in detail. SCEA features, components, and specifications are described in each section.

Features

The SCEA is a SCSI to SCSI workstation adapter which allows you to connect hard disk drives, erasable optical drives (without any software patches or special drivers), and tape drives to a workstation such as the VAXstation™

3100, DECstation™ 5000/200, Sun SPARCstation™, IBM RISC System/6000™

series, or Silicon Graphics IRIS INDIGO systems.

For purposes of this manual, the port connecting to the host computer (Jl on the SCEA) is called the Host SCSI Port; the port connecting to the target devices (J2) is called the Device SCSI Port. These target devices may include disk, tape, optical drives, jukeboxes, and tape stackers.

The host computer plays the role of initiator to the SCEA and SCSI devices, and the SCEA plays the role of target to the host computer at Jl. The SCEA, in turn, plays the role of initiator to SCSI devices from J2, the Device SCSI Port.

Host Computer

J1 plays target role

Figure 2-1: SCEA SCSI ports

SCEA

J2 plays initiator role

Target devices

Features and Components 2-1

(20)

Removable Media

When enabled, a removable drive is reported as removable. For the

V AXstation 3100, the VMS dismount drive will eject the media if the drive is removable. Place jumper shunt in W12-6 to enable this feature as shown in Table 2-1.

NOTE Do not use this feature with SCEAIJl or SCEAIJ2 for jukeboxes. When selected, the media will eject from the drive and you will not be able to access it inside the jukebox.

Table 2-1 Removable Media W12-6

W12-6

Note that (F) is factory setting.

Platform Control IN OUT

Removable Media enabled Removable Media disabled (F)

Platform control is available for the SCEA/J1 and SCEA/J2 and tells the SCEA what type of platform is being used. Default is W14 all OUT for DEC VAX. If you are using any other platform than DEC VAX, simply install jumper shunts into W14 location as shown in Table 2-2.

Table 2-2 Platform Control

Platform W14-1 W14-2 W14-3 W14-4 W14-5

(close to

J

5)

DEC VAX (F) OUT OUT OUT OUT OUT

IBM OUT OUT OUT OUT IN

SUN OUT OUT OUT IN OUT

PC OUT OUT IN OUT OUT

DEC ULTRIX OUT IN OUT OUT OUT

SGI IN OUT OUT OUT OUT

UNISYS OUT OUT IN IN OUT

Note that (F) is factory setting.

Multi-Hosting for VMS

CMD's multi-host solution can support disk, tape, and optical devices

including jukeboxes for VMS only. It gives you the ability to completely share an array of disks and tapes between multiple VAX systems running VAX

(21)

cluster software. Multi-hosting configuration instructions are given in Chapter 4. Refer to Appendix A for supported disk and tape devices.

SCSI Library Manager

The SCSI Library Manager (SLM or SLM/Unix) is an optional application software license that works exclusively with the SCEA for VAX/VMS and Unix systems.

SCEA

SCSI Library Manager was designed to work with multiple jukeboxes as well as a single jukebox with from one to five erasable optical or WORM drives installed. With just a few keystrokes, SLM controls all basic operations like inserting, removing, and flipping erasable or WORM cartridges from the drive unit.

In addition to giving you complete control of jukebox functions, SLM also has a build-in callable user interface allowing you to customize SLM to your requirements. This is especially useful for applications to support file

management. Refer to SLM or SLM/Unix Management Guides for installation and operation.

SCEA Models

The SCEA is sold in three basic versions: SCEA/E, SCEA/C and SCEA/J.

Although the basic SCEA is identical for each version, the function of the SCEA board is determined by the firmware installed by CMD during its final test. It is important that YOll understand the functions provided by each SCEA version as listed in this section. SCEA models and CMD model numbers are as listed in Table 2-3.

Table 2-3

SCEAModel SCEA/E SCEA/C SCEA/JI SCEA/J2

SCEA Models

CMDModel#

CSB-2000/E CSB-2000/C CSB-2000/Jl CSB-2000/J2

Devices Supported

Supports 2 drives (LUN 0 and 1)

Supports 7 drives (LUN 0, 1,2, 3, 4, 5, and 6) Supports a jukebox of one drive up to 32 slots (LUN 0, 1,2, 3,4, 5, and 6)

Supports a jukebox of more than one drive and more than 32 slots (LUN 0, 1,2,3,4,5, and 6)

The SCEA/E firmware is designed to provide a transparent hardware interface solution for erasable optical (MO) disks, 4-mm and 8-mm helical

Features and Components 2-3

(22)

scan tape drives, nonsystem-supported SCSI Winchester disk drives and other special SCSI peripheral devices without requiring patches or drivers to the host workstation operating system. SCEA/E does this by causing the SCSI peripheral to emulate a generic Winchester system disk or tape drive. The SCEA board and firmware recognizes the attached peripheral, then selects the .most appropriate device emulation type. SCEA/E supports up to two SCSI

peripherals.

The SCEA/C firmware provides expansion capabilities for your workstation's SCSI port. The SCEA/C provides SCSI LUN (Logical Unit Number) support for up to seven SCSI devices for each SCSI ID used. One SCEA/ C is required for each SCSI ID to be expanded. Multiple SCEA/Cs can be used to support up to a total of 49 SCSI devices per SCSI port. The SCEA/C also provides multi-hosting and peripheral sharing capabilities for DEC VMS-based V AXstations. The SCEA/ C also provides a "SCSI Pass-Through" mode for those applications where driverless operation is not desired or required; both

"pass-through" and SCEA/E hardware driver supported devices can be used on the same SCEA/C board (no additional SCEA board is required).

The SCEA/J firmware combines the capabilities of the SCEA/E and SCEA/C to provide a seamless integration solution for interfacing optical disk

jukeboxes, 4-mm and 8-mm tape cartridge handling systems, and most SCSI-based robotic devices when used in conjunction with CMD's SCSI Library Manager (SLM) software package.

Two versions of the SCEA/J firmware are available to support low-end (SCEA/Jl) and high-end (SCEA/J2) jukeboxes. SCEA/Jl supports one drive and 32 media slots or less and CMD's SLM Jl or SLM/lJnix Jl software license. SCEA/J2 supports up to six drives and 128 slots and CMD's SLM J2 or SLM/Unix J2 software license. The SCEA/Jl version will not accept commands from an SLM/Unix J2 software license, and vice versa. For more detail, refer to the SLM/Unix Management Guide.

Components

This section details the SCEA components. Figure 2-2 illustrates the SCEA.

(23)

~

~~

i

rvn

-

.... ~

~ :~

!

- -

li!l~ wt:! ,:.

ID ....

-:c -M

~

CD

~

It

RNe

CI3

o

+~

GNDI

o

CB

RNII CIS

o

&\ ceo

o

!

NI3 veB ...

UI RNS RN6 R3

U9 UIO

CI6 ORN7 UI7

UO

!£ill

U30

U29

1116 1117 R9

:H:

U37

C27 c;rl7

~IO~

~ n

~ !JI

®D

RNIB

Figure 2·2: seE A components

SCEA

-

14

~

1J]~

§..cJ'

CIB CI9

el7 0 0 ~!§~

o +Ouel

027 RNI2

R7 Iii w ~

Ii i m

U31 U32

o

ij

U39

Features and Components 2-5

(24)

LED Indicators

LED indicators light up when the SCEA is installed and powered ON. The green lights indicate normal functions of the SCEA; the red light indicates a possible problem.

LED DSI is located next to JI; LEDs DS2 and DS3 are next to J2; and LEDs DS4 and DSS are next to JS. Table 2-4 lists the LED indicators for the SCEA.

Table 2-4 LED Indicators

DSI Green LED. This LED is ON if Jl connector TERMPWR is active on the SCSI bus. This includes TERMPWR supplied by the SCEA or other device(s) on the SCSI bus.

DS2· Green LED. This LED is ON if J2 connector TERMPWR is active on the SCSI bus. This includes TERMPWR supplied by the SCEA or other device(s) on the SCSI bus.

DS3 Green LED. This LED is ON if J2 is selected for single-ended mode. This should normally be ON.

DS4 Green LED. This LED blinks during SCSI activity.

DS5 Red LED. This LED is ON if an error condition occurs.

(25)

SCEA

Specifications

Table 2-5 lists the controller specifications for the SCEA.

Table 2-5 Controller Specifications

Bus Interface

Software Supported

Multiple-Hosting Formatting

Optional Software LED Indicators Peripheral Interface SCSI Transfer Rate:

SCSI Bus Parity System Performance SCSI Driver /Receiver SCSI Cable Length Operating Temperature Relative Humidity Power Requirement

SCSI Bus Cabling

SCSI

DEC VMS, DEC ULTRIX, IBM AIX, SunOS, SCO Unix, SGI IRIX, MS-DOS 3.3 and above on 286/386 PC and Novell Netware on 386 PC.

Support multi-hosting for disks, optical drives, and tapes for VMS only.

On board format (ISO standard for optical erasable disk format)

SCSI Library Manager (SLM and SLM/Unix) Self test, error conditions

Small Computer System Interface (SCSI-2) up to 5.0 MB/sec in Synchronous Mode up to 3.0 MB / sec in Asynchronous mode Odd parity

Support disconnect/ reconnect capability and multi-host configuration

Single-ended

Single-ended, up to 20-feet (6-meters) 50 C to 500 C

100/0 to 90% , Noncondensing 5V DC, 2.3 A (max)

The SCEA contains two 50-pin SCSI ports. One of the ports is connected to the host computer, the other to the target devices. When the SCEA and the SCSI devices are installed in the same cabinet which meets EMI/RFI shielding requirements, a 25-signal twisted-pair cable must be used for connecting the SCEA (J2) and the SCSI devices. When the SCEA and the SCSI devices are installed in separate cabinets, a shielded SCSI cable should be used to meet FCC requirements.

A minimum conductor size of 28 AWG shall be used to minimize noise effects and ensure proper distribution of optional terminator power. The maximum cable length is 6.0 meters or 20 feet in single-ended mode.

Features and Components 2-7

(26)

Host SCSI Port

The Host SCSI Port, J1, on the SCEA is a 50-pin single-ended SCSI connector which connects to the SCSI port of the host computer (workstation). To the host computer, the SCEA looks very much like an ordinary target device.

Each device (initiator or target) on the SCSI bus requires a unique SCSI Identification address (specifically SCSI ID 0-7). SCSI ID 7 has the highest priority on the bus and SCSI ID 0 has the lowest priority. The SCEA is factory configured to SCSI ID 0 at J1. You can change this ID by selecting a SCSI ID for the SCEA that is not currently being used on the system (to check SCSI ID number perform show dev dk, for example, on V AXstation 3100). See

Chapter 3 for SCSI ID selections from on-board jumpers.

For example, if the target device is to be seen as SCSI ID 2 by the host, set the SCEA to SCSI ID 2 (by configuring the SCEA described in Chapter 3) and the target device to SCSI ID

o.

The SCEA and target device will be seen by the host as one device, SCSI ID 2 or DKA200 on the V AXstation 3100 (using show dev dk).

Host SCSI Port Termination

Terminator resistors, RN1, RN3, and RN4, are removable 220/330-ohm terminator resistor packs for the J1 Host SCSI Port. SCSI bus specifications require the cable to be terminated at both physical ends. Termination is usually required at J1 on the SCEA except in the V AXstation 3100 and DECstation™

5100. See Chapter 3 for proper installation instructions.

The SCEA can supply power to the TERMPWR (pin 26) of the SCSI connector J1 through a diode, a fuse (F1), and a jumper (WI). Since the SCEA plays the target role, it should not have to supply TERMPWR, therefore, WI should be out. However, if the host computer does not supply termination power, place jumper shunt on WI (see Chapter 3 for installation instructions).

Device SCSI Port

The Device SCSI Port, J2, on the SCEA is a 50-pin single-ended SCSI connector which connects to the target devices. The SCEA is factory configured to SCSI ID 7 at J2. See Chapter 3 for Device SCSI Port ID settings from on-board jumpers.

Since the SCEA is factory configured to SCSI ID 7 (at J2), the SCSI ID of the target devices connected to the SCEA should be set from SCSI ID 0 to 6 starting at SCSI ID O. For the V AXstation 3100, only one drive is initially

(27)

SCEA

supported, and the drive SCSI ID must be 0; others may be manually set using the Sysgen Connect Statement. For the Sun SP ARCstations and SPARCservers, the SCSI ID should start at O. Up to 7 drives are supported.

Device SCSI Port Termination

Terminator resistors, RN17, RN18, and RN19, are removable 220/330-ohm terminator resistor packs for the J2, Device SCSI Port. The SCSI bus

specifications requires the cable to be terminated at both physical ends of the SCSI bus. It is recommended that these resistors remain in place if this connector is at one physical end of the cable.

The SCEA supplies terminator power to the TERMPWR pin (pin 26) of SCSI connector (2) through a fuse (F2), a diode, and jumper block W19. To install terminator power, install W19. W19 should remain installed since the J2 SCSI port acts like an initiator to the target devices on the bus.

Any SCSI terminator (on-drive or external) needs to be powered by at least one SCSI device, otherwise the SCSI signals will be pulled down. Typically, an initiator (SCSI host adapter) provides the power to the on-board

terminator, the external SCSI terminator, or the on-drive terminator when the drive is powered OFF.

Anytime an external SCSI terminator (instead of an on-drive SCSI terminator) is used, the SCSI terminator power option of the SCEA has to be enabled at jumper shunt W19.

Features and Components 2-9

(28)
(29)

3

Installation

Installation of the SCEA may vary with each application. The SCEA may be installed inside the chassis of the SCSI device if space constraints allow, inside a storage box like the DEC BA42 Storage Expansion Box, inside a jukebox like the IDE 9000 or inside a dedicated peripheral enclosure. This section details installing the SCEA and its respective SCSI devices.

Installing the SCEA into a Storage Box, Shoebox, or System

To install the SCEA follow these instructions carefully.

1 Turn the host computer completely OFF and unplug the power cord from the wall.

2 Carefully unpack the SCEA and place on a non-metallic surface.

WARNING Be sure to wear anti-static wrist straps or equivalent to protect the SCEA from electro-static damage.

Installation 3-1

(30)

3 Carefully install the SCEA into an assigned slot inside a storage box, shoebox, or system, see Figure 3-1 for an example.

WARNING 0 Make sure the SCEA or any of its components are NOT directly connected to or touching metal surfaces; attach plastic washers on BOTH sides of the mounting screws.

Make sure there is proper ventilation in the storage unit.

Mounting Screws

i i

I

I I I

Plastic Washers ~ I

I I

Plastic Washers :

~

I

stand

OffS~

I

~

I I

~

Vl i :+

I I

I I

I I

0 :

I I

I I

I I

I I

I I

I I

~====v.::

I I

Top of Drive or Controller

I I

I I

:+

I I I

Figure 3-1: Shoebox installation example

Top & side of shoebox not shown for clarity

(31)

SCEA

4 Set Host SCSI Port ID (Jl) to 0 by making sure jumper(s) are removed from W12 pins. If another device on the SCSI bus has SCSI ID 0, set the

Jl

SCSI ID to 1,2,3, or another number up to 7 by placing jumpers over the pins as listed in Table 3-1 (see Chapter 2, section "Host SCSI Port"

for explanation of SCSI ID).

Table 3-1 Host SCSI Port 10 (J1) Jumper Selections

Host SCSI Port ID W12-1 W12-2 W12-3

SCSI ID = 7 (DO NOT USE- IN IN IN

reserved for Host Computer)

SCSI ID = 6 IN IN OUT

SCSI ID = 5 IN OUT IN

SCSI ID = 4 IN OUT OUT

SCSI ID = 3 OUT IN IN

SCSI ID = 2 OUT IN OUT

SCSI ID = 1 OUT OUT IN

SCSI ID = 0 (factory) OUT OUT OUT

Figure 3-2 illustrates an example of SCSI configuration for a system.

SCSI Bus Cable 10 =7 *

10 =7 *

10=0

Workstation 10=1

10=2 10=3 10=4 10=5 10=6 * Figure 3-2: SCSI 10 configuration

10 =7 *

10=0 10=1 10=2 10=3 10=4 10=5 10=6 *

Other SCSI device

10=2 *

* indicates SCSI bus termination.

Installation 3-3

(32)

5 Connect one end of the SCSI cable from the SCSI connector of the host computer to the SCEA at JI, Host SCSI port; see Figure 3-3.

WARNING To prevent damage to the SCEA, pin 1 of the SCSI cable and pin 1 of the SCEA must align.

SCEA

Figure 3-3: Host SCSI port (J1) cable connection

Jl

Pin 1

- - - R e d stripe designates pin. 1

If the SCEA is inside a storage box or shoebox, the cable connection will be similar to that shown in Figure 3-4.

(33)

SCEA

SCSI IN

J2

Jl

SCSI OUT

SCEA

Internal Cable

Red stripe designates pin

Shoebox (rear, transparent view)

To other SCSI devices or terminator

50 Pin Centronics Connector (Male or equivalent)

To Workstation

Figure 3-4: Shoebox or Storage Box J 1 SCSI connection

Installation 3-5

(34)

6 Terminate each physical end of the SCSI bus connected to JI. If SCEA is not at one end of the SCSI bus, remove terminators at JI. For V AXstation 3100 and DECstation 5100 systems, always remove terminators at J1.

Follow the instructions below (see Figure 3-5):

To remove terminators at /1:

Remove the three (3) terminators in locations RN1, RN3 and RN4 from the SCEA located near JI. Removejumper shunt in WI to disable TERMPWR at JI.

To install terminators at /1:

Put three (3) terminators in locations RN1, RN3 and RN4 near J1

(numbers must face J1). Put jumper shunt in WI to supply TERMPWR (check first to be sure the host computer is not supplying terminator power).

SCSI device

r----.!!--1Ij Device

SCEA port J2

Tenninators removed

W1 n~

removed ~~ Host SCSI

port J1

pin 1

. - - - 1 - -Red strip designating pin 1 To Host Computer Internal daisy chain ribbon cable Figure 3-5: Host SCSI port termination

7 Connect the appropriate 4-pin power cable to the power connector, J300.

Be sure pin 1 from the cable is aligned with pin 1 on the SCEA as shown in Figure 3-6. For connector information, see Appendix D.

(35)

SCEA

J2

Power connector from

system or device--~ _ _ .,...y

Yellow cable - - - I designates pin 1

Figure 3-6: Power connection

8 Make sure jumpers are on W13-1, W13-2, and W13-3 to identify the Device SCSI port 02) as ID 7. If another device on the SCSI bus has SCSI ID 7, set the J2 SCSI ID to 6, 5, 4, or another number down to 0 by placing jumpers over the pins as listed in Table 3-2 (see Chapter 2, section "Device SCSI Port" for complete explanation of SCSI ID; see Figure 3-1 also for details).

Table 3-2 Device SCSI Port 10 (J2) Jumper Selections

Device SCSI Port ID W13-1 W13-2 W13-3

SCSI ID = 7 (factory) IN IN IN

SCSI ID = 6 IN IN OUT

SCSI ID = 5 IN OUT IN

SCSI ID = 4 IN OUT OUT

SCSI ID = 3 OUT IN IN

SCSI ID = 2 OUT IN OUT

SCSI ID = 1 OUT OUT IN

SCSI ID = 0 OUT OUT OUT

Installation 3-7

(36)

9 Connect one end of a SCSI cable to the SCEA at J2, Device SCSI port;

pin 1 of the cable and pin 1 of J2 must align to prevent damage to the system (see Figure 3-7).

WARNING To prevent damage to the SCEA, pin 1 of the SCSI cable and pin 1 of the SCEA must align.

Jl SCEA

Pin 1 of non-shielded connector

Internal Cable

1 - - - - -Red stripe designates pin 1

Figure 3-7: Device SCSI port (J2) cable connection

10 Connect the other end of the cable to the SCSI device (align pin l's). Up to seven devices may be installed by correctly cabling to other SCSI devices.

Figure 3-8 shows the SCEAj C inside the subsystem rackmount chassis with devices connected and SCEAjE inside the optical drive.

(37)

SCEA

Subsystem Rackmount Chassis

To Workstation

Figure 3-8: Cabling example from inside Subsystem

Installation 3-9

(38)

11 Terminate each physical end of the SCSI bus connected at J2. DO NOT terminate devices in the middle of the SCSI bus; if the SCEA is in the middle of the SCSI bus; remove terminators at J2.

SCSI devices can be terminated directly on the device (see

manufacturer's documentation) or by using an external terminator as shown in Figures 3-8.

To install terminators at J2:

Put three (3) terminators in locations RN17, RN18, and RNI9 (numbers must face JI); put jumper shunt in WI9 (this allows for +5-volts to be sent to the external terminator at the end of the SCSI bus).

To remove terminators at J2:

Remove the three (3) terminators in locations RN17, RN18, and RN19, next to J2 on the SCEA. W19, TERMPWR, may be removed if another device is supplying terminator power. See Figure 3-9.

SCSI device

W19

installea

SCEA

To other SCSI devices

---

Terminators RN17, RN18,

I

RN19 installed

Host SCSI port J1

J2 is at one physical end of SCSI bus Internal single ended _ - - - I - ribbon cable

Device SCSI port J2

Figure 3-9: Device SCSI port termination

12 If you do not want the SCEA to supply terminator power (TERMPWR), remove jumper shunt at W19.

(39)

SCEA

Installing the SCEA into a TRIMM SCEAbox Enclosure

To mount the SCEA into the SCEAbox, follow these instuctions:

1 Put the SCEAbox on a flat surface.

2 Open the box carefully by following the instructions accompanying the SCEAbox. (Remove the screw in the top center of the back of the box and the two screws on the front bottom of the box. While facing the front of the SCEAbox, slide the top of the box chassis toward you and remove it from rest of the SCEAbox.)

3 Align the SCEA in the SCEAbox with

JI

facing the back of the box (SCSI connectors are at the back of the box). DO NOT mount it to the

standoffs in the SCEAbox at this time.

4 Connect the 4-pin power cable to the power connector, J300. Make sure pin 1 from the cable is aligned with pin 1 on the SCEA (see Figure 3-6 for reference). For connector information, see Appendix D.

Installation 3-11

(40)

5 Connect the' long internal SCSI cable from the SCSI connector in the SCEAbox to the JI, Host SCSI port, on the SCEA. (Route the SCSI bus cable under the SCEA board carefully before plugging into the

connector.) See Figure 3-10.

Internal Cable

Red stripe designates pin 1

50 Pin Centronics Connectors (Female or equivalent)

Figure 3-10: Connecting SCSI cables in the SCEAbox

SCEA

50 Pin Centronics Connector (Male or equivalent)

6 Connect the short internal SCSI cable from the SCSI connector of the SCEAbox to the J2, Device SCSI port, on the SCEA.

(41)

SCEA

7 With the SCEA over the four white mounting standoffs on the bottom of the SCEAbox, push the SCEA down firmly so that the standoffs are secure in the four holes in the edges of the SCEA. This affixes the SCEA's location in the box. See Figure 3-11.

I I I

~

white mounting standoffs

8

I I

I I

A ~~

SCEAbox (rear, transparent view with connectors removed)

Figure 3-11: Installing the SCEA into the SCEAbox

8 Connect the two 3-pin black connectors from the Host SCSI ID selector (closest to power switch) to the Host SCSI Port ID jumper selections W12- 1, WI2-2, and WI2-3. The blue wire should be on W12-1 and be close to U41. The brown wire should be on W12-3 and be close to C30 on the SCEA. See Figure 3-12.

Device SCSI IDselector

Device SCSI connectors

Figure 3-12: Device and Host 10 selectors

Host SCSI IDselector

Host SCSI connectors

Power switch

9 Connect the two 3-pin black connectors from the Device SCSI ID selector to the Device SCSI Port ID jumper selections WI3-1, W13-2, and WI3-3.

The blue wire should be on W13-1 and be close to U44. The brown wire should be on W13-3 and be close to U43 on the SCEA.

Installation 3-13

(42)

11 Set the SCSI ID for both the host and the device using the Device and Host SCSI ID selectors; press the top buttons to decrement the numbers and the bottom buttons to increment the numbers.

a Set the Host SCSI ID selector to O. If another device on the SCSI bus has SCSI ID 0, set it to 1,2, 3, or another number to (see Chapter 2, section "Host SCSI Port" for complete explanation of SCSI ID; see Figure 3-12 also for location of Host SCSI ID selector).

b Set the Device SCSI ID selector to 7. If another device on the SCSI bus has SCSI ID 7, set it to 6, 5,4, or another number down to 0 (see Chapter 2, section "Device SCSI Port" for complete explanation of SCSI ID).

12 Terminate each physical end of the SCSI bus by following these instructions:

a If SCEA is not at one end of the SCSI bus, remove terminators at Jl.

For VAXstation 3100 and DECstation 5100 systems, always remove terminators at Jl (see Figure 3-5).

To remove terminators at Jl:

Remove the three (3) terminators in locations RNl, RN3 and RN4 from the SCEA located near Jl. Remove jumper shunt in WI to disable TERMPWR at Jl.

To install terminators at J1:

Put three (3) terminators in locations RNl, RN3 and RN4 near Jl (numbers must face Jl). Put jumper shunt in WI to supply TERMPWR (make sure the host computer is not supplying terminator power).

b DO NOT terminate devices in the middle of the SCSI bus; if the SCEA is in the middle of the SCSI bus; remove terminators at J2.

SCSI devices can be terminated directly on the device (see

manufacturer's documentation) or by using an external terminator as shown in Figures 3-8.

To install terminators at J2:

Put three (3) terminators in locations RN17, RN18, and RN19 (numbers must face Jl); put jumper shunt in W19 (this allows for +5-volts to be sent to the external terminator at the end of the SCSI bus).

(43)

SCEA

To remove terminators at J2:

Remove the three (3) terminators in locations RN17, RN18, and RN19, next to J2 on the SCEA. W19, TERMPWR, may be removed if another device is supplying terminator power. See Figure 3-10.

C If you do not want the SCEA to supply terminator power (TERMPWR), remove jumper shunt at W19.

13 Close the SCEAbox carefully by sliding the cover of the TRIMM chassis from the front to the back. Make sure the two notches in the cover chassis are on top of the bottom chassis; this secures the box completely.

14 Put the three scews back into the back center and bottom front of the SCEAbox.

15 Plug the female end of the power cord into the back of the SCEAbox;

plug the male end into a wall power outlet, see Figure 3-12.

16 Connect one end of an external SCSI cable to the Host SCSI connector at the back of the SCEAbox; either the top or bottom connector on the right side of the box can be used.

17 Connect the other end of the external SCSI cable to the host computer (align pin 1 of the cable to pin 1 of the connector).

18 Connect one end of an external SCSI cable to the Device SCSI connector at the back of the SCEAbox; this connector is either the top or bottom connector on the left side of the box.

19 Connect the other end of the external SCSI cable to the SCSI device connector (align pin 1 of the cable to pin 1 of the connector). Up to seven devices may be installed by correctly cabling to other SCSI devices as shown in Figures 3-8.

Installation 3-15

(44)
(45)

4

Configuration

This chapter details software configuration for the system to recognize devices located on the SCSI bus, the On-Board Utility to assist you in setting up the SCEA and your system and multi-hosting configuration for VMS. Remember, each device on each SCSI bus must have a unique SCSI ID number.

VMS, VAXstation Configuration

Your VMS system will auto-configure only LUN 0 for each SCSI ID; through the SCEA VMS recognizes the target device with SCSI ID 0 as LUN O. Other devices LUN 1 to LUN 7 connected to the SCEA must be manually configured to the system using the VMS Sysgen Connect Statement.

Follow these instructions to configure your system for more than one LUN:

1 Be sure all cables are securely connected and termination is correct. See Sections "Installing the SCEA" and "Installing SCSI Devices."

2 Power "ON" and boot the system.

Configuration 4-1

(46)

3 At the system prompt, $, enter one of the following statements for viewing the respective devices:

show dev dk show dev mk show dev gk

to view disk drives to view tape drives

to view generic drives like jukeboxes Determine from which SCSI port of the V AXstation the SCEA is connected, either A or B; dka or dkb, mka or mkb, or gka or gkb will dis- play.

4 At the $ prompt, enter:

mc sysgen

5 After you have determined to which SCSI port of the V AXstation the SCEA is connected, at the sysgen> prompt, enter one of the following con- nect statements for each respective device (Table 4-1 lists mapping for the devices):

connect dkA#O?lnoadapter connect mkA#O?lnoadapter connect gkA#O?lnoadapter connect dkB#O?lnoadapter connect mkB#O?lnoadapter connect gkB#O?/noadapter Where:

for disk drive on V AXstation SCSI port A for tape drive on V AXstation SCSI port A for generic drive on V AXstation SCSI port A for disk drive on V AXstation SCSI port B for tape drive on V AXstation SCSI port B for generic drive on V AXstation SCSI port B

# = the SCSI ID for

Jl

of the SCEA

?

=

the SCSI ID of device other than 0 on J2 SCSI bus (see the example on the next page).

DEC Alpha AXP systems use sysman to connect devices. At the $ prompt enter:

mcr sysman

At the sysman> prompt, enter one of the following connect statements for each respective device (Table 4-1 lists mapping for the devices):

(47)

SCEA

io connect dkA #O?:lnoadapterl drive=sys$dkdriver for disk drive on Alpha SCSI port A for tape drive on Alpha SCSI port A io connect mkA#O?:lnoadapterldrive=sys$dkdriver

io connect gkA#O?:lnoadapterl drive = sys$gk driver for generic drive on Alpha SCSI port A io connect dkB#O?:lnoadapterl drive=sys$dkdriver for disk drive on

Alpha SCSI port B io connect mkA#O?:lnoadapterldrive=sys$mkdriver for tape drive on

Alpha SCSI port B io connect dkA#O?:lnoadapterl drive=sys$dkdriver for generic drive on

Alpha SCSI port B Where:

#

=

the SCSI ID for

Jl

of the SCEA

?

=

the SCSI ID of device other than 0 on J2 SCSI bus (see the example on the next page).

Table 4-1

Target Device SCSI ID 0 SCSI ID 1 SCSI ID 2 SCSI ill 3 SCSI ill 4 SCSI ill 5 SCSI ill 6

Mapping for Drives

Host Devices SCSI ill x, LUN 0 SCSI ID x, LUN 1 SCSI ill x, LUN 2 SCSI ill x, LUN 3 SCSI ill x, LUN 4 SCSI ill x, LUN 5 SCSI ill x, LUN 6

For example, our V AXstation recognized the disk drive located at LUN 0; it did not recognize the jukebox which consists of two devices-the drive and the robotics. For the jukebox, configured to SCSI ID 2 Gukebox drive) and SCSI ID 3 (robotics), we entered gkal02 for generic drive SCSI ID 1 (SCEA) L UN 2, then entered gkal03 for generic drive SCSI ID 1 (SCEA) LUN 3. See Figure 4-1 for details.

Configuration . 4-3

(48)

VAXstation

Target (J1) SCEA SCSI ID=1

Initiator (J2) SCSIID=7

SCSI 10=0 dkal00 (LUND) DISK DRIVE SCSIID=2 gkal02 (LUN2) JUKEBOX DRIVE SCSI ID=3 gkal08 (LUN8) JUKEBOX ROBOTICS Figure 4-1: SCSI 10 and LUN for VAXstatJon

6 When completed, at the sysgen> prompt enter:

exit

To view all disk devices, use show dev dk as explained in number 3, show dev mk for tape devices, or show dev gk for generic devices.

SunOS Configuration

To configure your system using SunOS version of Unix, follow the instructions below.

1 Enter the following line at the system prompt:

cd lusrlkvmlsyslsun4clconf Where

sun4c

=

SP ARC station or SP ARC server and the number is the' old lines.

NOTE This directory is for a typical SP ARC station. Your configuration may be somewhat different.

2 Copy your configuration file to a new name, for example "SCEA"

cp <your configuration file> SCEA

(49)

SCEA

3 Open the SCEA file just created.

4 Locate the target SCSI ID number that is not being used and set it for use with the SCEA.

5 Add a line to the SCEA file to reflect the presence of the SCEA and devices connected by performing the following procedures:

a Locate configuration regarding SCSI (using the vi Editor, search for SCSI by entering Iscsi).

b Add the following statement to show SCSI ID numbers' set for the SCEA and its respective devices (see Table 4-1 and the example in Figure 4-2 for appropriate SCSI identification). DO NOT edit lines with existing devices!

disk sd+ at scsibus

+

target

+

lun +

NOTE There is no space between sd and

+

Where:

+

in sd

=

the numeric variable given to represent the SCSI device (this number will show in the /dev directory as /dev/sdl, for example)

+

for scsibus = available bus (usually 0 unless another SCSI adapter board has been added)

+

for target = SCSI ID number for Host SCSI Port (J1, SCEA)

+

for lun

=

SCSI ID number for the device (set on the device).

The following is an example of a configuration file (see Figure 4-2):

disk sdl scsibus 0 at target 1 lun 1 disk sd2 scsibus 0 at target 1 lun 2 disk sd3 scsibus 0 at target 1 lun 4

In this example, target 1 represents the SCSI ID of the SCEA at J1;

lun 1 is the logical unit number (L UN) of the target device from J2 and is named sdl; the second target device at lun 2 is named sd2, an- other target device at lun 4 is named sd3.

5 Save the SCEA file (in vi editor, the command is ZZ).

Configuration 4-5

(50)

SPARCstation

Initiator SCSI 10=7

SCSIID=1 sd1 (LUN1)

SCSI 10=2 sd2 (LUN2) SCSI 10=4 sd3 (LUN4) Figure 4-2: SCSI 10 and LUN for SPARCstatlon

6 Run config by entering the following statement; the screen will then display the message, Doing a "make depend."

config SCEA

7 Enter the following to generate the file vmunix:

cd .. ISCEA make

8 At the prompt, enter the following statement:

cp .Ivmunix Ivmunix.new shutdown

halt

9 The system halts and displays the prompt, boot the system in single-user mode by entering:

b Ivmunix.new -s

(51)

10 Test the system, if it works, save the old kernel under a different file name and install the new one in /vmunix by entering the following commands:

cd I

mv vmunix vmunix.sav mv vmunix.new vmunix

NOTE Make sure the new version is accurately spelled vmunix.

11 Reboot the system.

UL TRIX, DECstation Configuration

SCEA

Follow the steps below to configure your system; first note the example be- low. This section describes procedures to configure and add new devices to UL TRIX running on a DEC station.

1 Enter the following at the system prompt:

cd Isyslconflmips

2 Copy your configuration file to a new name, for example, "SCEA:"

cp <your config file> SCEA 3 Edit the SCEA file just created.

4 For each medium changer, add a disk device corresponding to the SCSI ID setting of its associated SCEA/J board.

NOTE Since ULTRIX does not support LUNs, the medium changer's SCSI ID must be 0).

disk rz* at <type>? drive # where:

* = disk unit number from 0 to 7.

# = SCSI ID number of the medium changer's SCEA/J board (as seen from the host side).

Configuration 4-7

Referenzen

ÄHNLICHE DOKUMENTE

The saturated vapor density versus temperature is deduced from absorption measurements.. The fluorescence quantum efficiency of both dyes in the vapor phase is approximately 1.5 x

biosphere
in
the
Easter
Mediterranean.
We
work
on
the
deep
central
delta
of
the


Sines remains, as prior seen, as a very specialized liquid bulk port, although the containerized cargo segment is being gradually rising in importance (Appendix 4). The

60 participants have been selected for the experiment, and each participant is supposed to test and rate every packaging of exactly one toothpaste type on a 1-5 scale. Which type

The SLLN yields an idea called the Monte Carlo Method of direct sim- ulation.. (Interestingly, it is often much easier to find and simulate such an X than to compute

Verify that your SCSI cable is properly terminated at each end, and that no other terminators are installed if there are more than two SCSI devices (including

In the second part, I present seven ‚strategies of commemoration’ (Documenting, Interpreting, Investigating, Exhibiting of fragmentarized Memories, Swearing/staging of Trauma,

If more than one drive has a status change, the tape identifiers are written to the Status Change Register in FIFO order after each interrupt is