Geophysical Research Abstracts Vol. 18, EGU2016-17160-1, 2016 EGU General Assembly 2016

© Author(s) 2016. CC Attribution 3.0 License.

Vulnerability of electricity transmission infrastructure to natural hazards

Nadejda Komendantova (1,2)

(1) International Institute for Applied Systems Analysis (IIASA), (2) ETH, Zurich

Electricity transmission system is a very complex system, which consists of several elements, such as overhead lines, substations and transformers, covers wide areas, is interconnected with several networks with numerous inter-dependencies. This highly integrated system is exposed to several hazards, leading to interruption of power supply. Natural hazards, such as an increased frequency of extreme weather events, including storms, icing, wet snow deposits, lighting, floods, avalanches, rock falls and landslides or changing air temperature have effects on transmission and lead to destruction of this infrastructure, which is also critical for society as it guarantees functioning of vital for society services.

The reliability of critical electricity transmission infrastructure depends on its ability to ensure normal op- eration, to limit number of incidents and to avoid major incidents and to limit consequences of major incidents.

The concept of reliability is closely connected with the concept of resilience, which is understood, in general, as the ability of a system to react and recover from anticipated disturbances and events. In regards to electricity transmission resilience is the ability of the power system to adapt, self-organize and recover or achieve the level even higher than those before the shock.

This paper reviews three major natural hazards disasters, which resulted in significant blackouts in Europe.

The first one is the 2003 blackout in Italy, which was caused by flash-over from trees. The second one is the 2003 blackout in Sweden, which was caused by rainstorms. The third one is the 2005 blackout in Germany, which was caused by wet snow. The inter-comparative analysis of these events allowed us to develop recommendations on electricity transmission network resilience.

Referenzen

ÄHNLICHE DOKUMENTE

• Simultaneously there was a high amount of wind electricity which fed into the grid 10,000 MW from wind turbines to Western and Southern Europe grids. •

The major regional ozone depletion events that were visible at all coastal stations, and discussed above, can also be seen in Fig. The August event is clearly evident in Site C as

The model ensemble mean annual mean temperature change, LIG minus pre-industrial (Fig. 6a), is characterised by maximum warming at high latitudes, especially in the Arctic..

From this observation, one could conclude that thermodynamic growth conditions can vary substantially within the surveyed region, such that a 1-D ther- modynamic growth model for

Measured vertical profiles of ozone mixing ratio with the DIAL along the inbound flight track, and in situ measurements (gray line) along the outbound flight track (position B1 in

The time series of the cost function (Fig. 12) and simulated ice fields (Fig. 13b, e and h) were obtained from a model run for which the mean parameter values obtained from

3 Simulated mid-Pliocene ocean circulation 3.1 Atlantic Meridional Overturning Circulation The PlioMIP models simulate a reasonable pre-industrial AMOC with maximum values of

The concentrations measured during this cruise were lower than the average surface measurements of DMS (1.8 nmol L −1 ), DMSP d (5.9 nmol L −1 ), and DMSP p (16.2 nmol L −1 ) based