• Keine Ergebnisse gefunden

EMPIRICAL MODELS FOR TOTAL BED LOAD ESTIMATION CALIBRATION AND RANGE OF APPLICATION OF DIFFERENT MODELS

N/A
N/A
Protected

Academic year: 2022

Aktie "EMPIRICAL MODELS FOR TOTAL BED LOAD ESTIMATION CALIBRATION AND RANGE OF APPLICATION OF DIFFERENT MODELS"

Copied!
2
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

– – – –

EMPIRICAL MODELS FOR TOTAL BED LOAD ESTIMATION

CALIBRATION AND RANGE OF APPLICATION

OF DIFFERENT MODELS

Warin Bertschi1, Gabi Hunziker2, Hans Kienholz1

Since the early eighties, several empirical models for total bed load estimation during extreme events have been developed by different authors. All these models have in common that they were developed and tested on local conditions only. Therefore, they can hardly be transferred to other areas or regions because of lacking knowledge about parameter settings.

GOALS

This study aims to adapt well-known empirical bed load estimation models for extreme events (Zeller [1985], Kronfellner-Kraus [1982], D’Agostino [1996], Hampel [1980]) to Swiss conditions and to point out their different strengths and weaknesses. Furthermore, the input data needed for (the individual) models should derive on the basis of available digital data.

Thus an objectively comprehensible procedure should be ensured. The final product represents a recommendation for the derivation of the parameters, for the calibration of the models and for the extent of their areas of application.

INVESTIGATION AREAS AND REFERENCE VALUES

The models were tested on altogether 133 mountain torrent catchments in the prealps or alpine region. They are distributed on the following groups of geologies: "Crystalline",

"Lime", "Flysch" and "Molasse". Estimated bed load volumes derived from hazard assessments serve as comparison and calibration sizes. First of all, a comparison row of a bed load volume with a recurrence interval of 100 years had to be derived from known, estimated bed load volumes. With the aid of this comparison row the models could then be adapted and calibrated.

DIGITAL INPUT DATA

The available digital data in Switzerland, in particular the digital elevation model, the stream network, the Hydrologic Atlas of Switzerland (HADES) as well as the geotechnical map represented the basis for the computation of the input parameters. Analyses during the collection phase made clear that these basic data meet the above mentioned standards of this study.

1 University of Bern, Geographical Institute, Hallerstrasse 12, CH-3012 Bern, Switzerland (phone: +41-(0)31- 6318859; fax: +41-(0)31-6318511; e-mail: bertschi@giub.unibe.ch, kienholz@giub.unibe.ch

2 Abteilungsleiterin Naturgefahren, Geo7 AG, Neufeldstrasse 3, CH-3012 Bern, Switzerland (phone: +41- (0)31-3004433; fax: +41-(0)31-3027611; e-mail: gabi.hunziker@geo7.ch

(2)

– – – –

RESULTS

This study allows making recommendations for the application range as well as for the settings of the models.

Important for the application of these models is the fact, that with increasing catchment areas the proportional adjustment-quality does not decrease. The given recommendations can be used for catchment areas with sizes from one to ten km2.

The adjustment of the models was achieved by minimizing the deviation between estimation (comparison raw) and modelling. This way, the models could be centred optimally in the estimated values. Fig. 1 displays how different factors (pos. factor = modelled bed load/estimated bed load, neg. factor is inverse) are distributed over the different geologies.

The nearer the factors lie to 1 or -1, the nearer lies the modelling value at the measured value.

comparison of the difference factor between estimation (comparison row) and modelling (Zeller [1985])

-16.00 -12.00 -8.00 -4.00 0.00 4.00 8.00 12.00 16.00

differencefactor [ ]

Cristaline Lime Lime BL Lime DF/LS

"Molasse"

"Flysch"

"Flysch" BL

"Flysch" DF/LS mean

Fig. 1:Overview of the positive and negative difference factors, modelled with the Zeller [1985]

model (pos. factor = model bed load/estimated bed load, neg. factor is inverse; BL = “normal”

bed load, DF = debris flow, LS = landslide)

The computations for all mentioned models lie on an average around the factor 2 - 3 over and/or 1.5 - 2.5 under the estimations.

Furthermore it can be said, that the very simple models of Zeller and Kronfellner Kraus (one or two input parameters) provide equally good adjustment results as more complex models with a large number of input parameters do.

RANGE OF APPLICATION

The results of this study can serve practitioners as orientation guide for their fieldwork, but should be interpreted and used with the necessary care. Furthermore it could be a possibility for public authorities to control estimations or to check what type of mountain torrent it is.

Keywords: mountain torrent, bed load estimation, empirical model

Referenzen

ÄHNLICHE DOKUMENTE

Five different tetragonal unit cell settings from the literature (obtained on the basis of symmetry considerations) were used for the refinement of the crystal structure of YB 2 C 2

3.16 Posterior distribution: Mixed model - sticky information prices and Calvo wages, Mixed model - sticky information prices and Calvo wages estimated without price markup

The main difference in terms of the model is that in this article all yields are observed with noise, while Creal and Wu 2015 assume that the number of yields observed without noise

The choice of the auxiliary model is motivated by the fact that there is a rather natural correspondence between the two models: besides having the same number of parameters and

Recently, two models of input-output type have been developed for the Italian economy. The INTIMO model covers the economy as a whole, while TIM is a biregional model confronting

First, we will study VaR forecasts estimated using the standard normal distribution assumption for all sample sizes and examine whether their performance depends on the choice of

Im obersten Teil der Beurteilungsmatrix (Abb. 5) werden die lokalen Standortfaktoren und Bedingungen im Gerinneabschnitt selber beurteilt, im mittleren Teil die Beeinflussung

x Rough estimation of total bed load of the torrent system transported to the fan apex during an extreme event, developed by the 60 analyzed watersheds and extreme events