FHA Anschlüsse
Stahlbau Schrauben
Grundaufgaben Seite 1/1
Provided, the Gusset plate is made of S355, the properties of the connecting welds should be:
Correlation factor taken from EN 1993-1-8 – 4.5.3.2 Table 4.1:
βw = 0,9 for S355 with fu = 510 N/mm2
Partial safety factor taken from EN 1993-1-8 – 2.2 Table 2.1 footnote:
γM2 = 1,25
Design shear strength according to EN 1993-1-8 – 4.5.3.3 eq. (4.4) f,vw,d = fu / (βw * γM2 * √3)
f,vw,d = 510 N/mm2 / (0,9 * 1,25 * √3) = 262 N/mm2
FH Augsburg – Studiengang Bauingenieur Bearbeiter: Prof. Dr. P. Knödel
Baumgartner Str. 16, D-86161 Augsburg Bearbeitungsstand: 26.04.2007
Tel. +49(0) 821 – 5586 – 102, Fax – 110 Druck tt.04.jj 09:02
fba-b@rz.fh-augsburg.de /tmp/jodconverter_e4c7df3a-b9f3-42e3-9317-3fabd09121b3/tempfile_5106.doc