• Keine Ergebnisse gefunden

(1)1592 Notizen Measurement of Fluorescence Lifetimes of Coumarin Laser Dyes with a 3Iode-Locked Krypton Ion Laser * J

N/A
N/A
Protected

Academic year: 2022

Aktie "(1)1592 Notizen Measurement of Fluorescence Lifetimes of Coumarin Laser Dyes with a 3Iode-Locked Krypton Ion Laser * J"

Copied!
2
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

1592 Notizen

Measurement of Fluorescence Lifetimes of Coumarin Laser Dyes with a 3Iode-Locked Krypton Ion Laser *

J. H. Richardson, L. L. Steinmetz, S. B. Deutscher, W. A. Bookless, and W. L. Schmelzinger

U niversity of California, Lawrence Liverm ore L aboratory, Liverm ore, California, USA

Z. N aturforsch. 33a, 1 5 9 2 -1 5 9 3 (1978);

received October 16, 1978

The fluorescence lifetime of four coum arin laser dyes (C-7, C-30, C-102, and C-120) were m easured in three different solvents (m ethanol, ethanol an d w ater) a t dilute and lasing concentrations. The lifetime generally decreases for th e more hydrophobic dyes as th e solvent polarity increases. There is little change w ith concentration due to th e large Stokes shift.

Molecular parameters for lasing dyes are necessary for both modeling laser efficiency and calculating scale-up parameters. It is known that the fluores­

cence lifetimes of xanthene dyes (e.g., rhodamine 6G) have a marked dependence on concentration [2]. The small Stokes shift is largely responsible for this concentration dependence. Another major class o f laser dyes, the coumarins, exhibit a large Stokes shift [3]. Despite being the important class of blue lasing dyes however, there are little experimental data concerning the fluorescence lifetimes of sub­

stituted coumarins [4—6]. Consequently, we have measured the fluorescence lifetime of coumarin 7, coumarin 30, coumarin 102, and coumarin 120 in three common laser solvents (water, methanol, and ethanol) at dilute (10- 6 M) and lasing (10- 4 M) concentrations.

The coumarin dyes Avere obtained from Eastm an Kodak and used without further purification.

Spectroquality methanol (Burdick and Jackson), 95% ethanol (Gold Shield), and deionized and distilled water were the solvents.

A mode-locked krypton ion laser was used as the excitation source [7]. The near uv line at 413.1 nm was used to excite the coumarin dyes. Typical parameters when mode-locked were 300 mW aver­

age power and approximately 60 ps FWHM, corre­

sponding to approximately 60 W peak power. The

* W ork performed under th e auspices of the U.S. D e p a rt­

m ent of Energy by the Lawrence Liverm ore L aboratory under contract num ber W-7405-ENG-48.

R ep rin t requests to Dr. J . H. R ichardson, Lawrence Liverm ore Laboratory, U niversity of California, Liverm ore, California 94550, U.S.A.

repetition rate was stepped down to 40 kHz before exciting the sample with a Bragg cell. This acousto- optic device was mounted externally to the laser cavity. The excitation beam was attenuated to approximately 6 W peak power and diffused to minimize stimulated emission and non-linear effects.

The fluorescence was detected with a RCA C 31024 photomultiplier tube biased to decrease the response time [8]. A Schott KV 450 long pass filter was used to eliminate scattering. The signal was processed by a boxcar integrator with a 350 ps sampling head (Princeton Applied Research, 162/

163). The overall system response o f 1.5 i 0.2 ns was measured with a Ludox scattering solution. The experimental data in all cases were fitted by a single straight line on a semi-log plot. All fluores­

cence lifetimes were corrected for the system response using a numerical convolute and compare procedure.

Kr ion laser

Prism Plasma

Fig. 1. Schem atic of the experim ental ap p aratu s for m easur­

ing nanosecond fluorescence lifetimes. The excitation source depicted is a mode-locked k rypton ion laser synchronously pum ping a coum arin dye laser.

(2)

Notizen 1593

The system was calibrated using solutions of rhodamine 6G in ethanol (10~6 M) and riboflavin in water (10~5 M). Rhodamine 6G was excited directly with the mode-locked output at 530.9 nm from the krypton ion laser. Riboflavin was excited at 502 nm using the mode-locked output from a synchronously pumped coumarin 30 dye laser [9 — 11]. Typical output parameters were 40 mW average power and pulse widths less than 25 ps.

Once again, the peak power actually incident on the sample was less than 10 W and the repetition rate was decreased to 40 kHz. Figure 1 is a schematic of the complete experimental apparatus.

Table 1. Fluorescence lifetimes of coumarin laser dyes.

Lifetim e (ns)

Dye Solvent IO-6 M IO-4 M

Coumarin 7 w ater 2.6 3.0

methanol 3.4 3.0

ethanol 3.9 3.9

Coumarin 30 w ater 1.6 _

methanol 2.1 1.9

ethanol 2.7 2.7

Coumarin 102 w ater 7.4 7.2

methanol 5.2 4.3

ethanol 6.5 5.7

Coumarin 120 w ater _ 6.0

methanol — 6.0

ethanol — 4.8

[1] Based on p a rt of a presentation given a t th e 176th N ational Meeting of the American Chemical Society, Miami Beach, Florida (September, 1978).

[2] K . A. Selanger, J . Falnes, and T. Sikkeland, J . Phys.

Chem. 81, 1960 (1977).

[3] K . H . D rexhage, J . Res. NBS 80 A, 421 (1976).

[4] J . K nof, F. J . Theiss, and J . W eber, Opt. Comm. 17, 264 (1976).

[5] J . Knof, F. J . Theiss, and J . W eber, Z. N aturforsch.

33a, 98 (1978).

[6] L. P arm a and N. Omenetto, Chem. Phys. L ett. 54, 544 (1978).

[7] L. L. Steinm etz, J . H. Richardson, and B. W. W allin, Appl. Phys. L ett. 33, 163 (1978).

The measured lifetimes of 4.8 and 4.4 ns for rhodamine 6G and riboflavin agree well with the literature values [5, 12]. The measured values for the coumarin dyes are summarized in Table 1. All standard deviations are ^ 0.2 ns. Signal-to-noise from the dilute coumarin 120 solutions was too poor to obtain good lifetime data. The more concentrated solution of coumarin 30 in water was turbid.

The more hydrophobic coumarins lasing at the longer wavelengths exhibit a smooth increase in lifetime as the solvent becomes less polar and a poorer source of hydrogen bonding (all the couma­

rins exhibit a large increase in basicity in the excited singlet). The most hydrophilic coumarin, coumarin 120, actually shows a decrease in lifetime as the solvent becomes less polar. For comparison replacing the amino group with a diethyl amino group greatly decreases the lifetime of the excited state [4]. The most rigid dye, coumarin 102, exhibits the longest lifetime.

All the coumarins exhibit a large Stokes shift, attributable to the large increase in dipole moment upon excitation. Thus, there is little change in lifetime upon changing concentration from 10~6 to IO"4 M.

We would like to thank B. W. Wallin for technical assistance in the early stages of this work, M. A.

Revelli for assistance with the computer calculations, and R. N. Zare for suggesting coumarins as a likely candidate for lifetime studies.

[8] B. Leskovar, an d C. C. Lo, Nucl. Instrum . Methods 123, 145 (1975).

[9] L. L. Steinm etz, J . H . R ichardson, and B. W. W allin, presented a t th e Topical Meeting on Picosecond Phenom ena (May, 1978), H ilton H ead, S.C.

[10] J . H. R ichardson, L. L. Steinm etz, S. B. D eutscher, W. A. Bookless, an d W. L. Schmelzinger, Anal. Bio- chem., subm itted for publication.

[11] L. L. Steinm etz, J . H . R ichardson, W. A. Bookless, and B. W. W allin, m anuscript in preparation.

[12] G. G. G uilbault in „P ractical Fluorescence: Theory M ethods and Techniques“ , Marcel Dekker, N .Y., New Y ork 1973, page 17.

Referenzen

ÄHNLICHE DOKUMENTE

Wir bieten dir als weltweit führende Wirtschaftsprüfungs- und Beratungsgesellschaft ein Maximum an Möglichkeiten für einen Karriereweg nach deinen Vorstellungen!. Unser Denken

Fig.3 shows the result of a) time series of basal normal stress (black line) and cross sectional area (gray line) on the Sakurajima force plate and b) time series of unit

From coupled measure- ments of CO2 assimilation and chlorophyll fluorescence (Cornic and Briantais, 1991) it was concluded that, for a given irradiance, desiccation

Our investigations of the infl uence of IA are based on the direct comparison of the reference with the TLS-distance. 1: Measurement setup a) for close range, b) for longer

Therefore, we calculated different cut-off values, considering each area of the buccal surface for the zero value assessment and testing in order to eliminate the zero

With varying degrees, their surfaces were irregular and rough compared to those from PZE osteotomy (Figure 5.6, 5.8, 5.9, and 5.10). This finding agrees with what Panduric et al.

From the point of view of the history of science, Gessner’s model has advantages in comparison with Fleming’s, namely the more clear introduction of historical dimension

The atomic resolution structure of a potassium-selective ion channel named NaK2K has allowed us to observe that a hydrophobic residue at the bottom of the selectivity filter,