MANUFACTURER 8< MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND A V AILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER 8< MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Astrocom Avanti Communications Avanti Communications

ATS-1 Model 100 Model 110

Async/sync converter Interface converter Interface converter

Async to sync RS-232-C to V.35 RS-232-C to A T& T 301/303

19.2K Governed by DCE/DTE Governed by DCE/DTE

Async/sync

- -

Full duplex

- -

ASCII

- -

RS-232-C 1 V.35 (DCE), 1 1 301/303, 1

RS-232-C RS-232-C

Any modem Any RS-232-C Any RS-232-C

Leased lines Direct Direct

Status LEDs

- -

295 550 1,000

Vendor Vendor Vendor

2 weeks 30 30

-

June 1976 June 1976

- - -

Automatic speed adjust- Designed to interface Interfaces DTE with ment to synchronous DTE with RS-232-C in- RS-232-C to DCE with device rate; no internal terface to DCE with A T& T 301/303; converter configurations required; V.35; into converter kit includes one six- break detection and kit incl. one six-foot foot cable

propogation cable

Avanti Communications Avanti Communications Avanti Communications

Model 130 Model 140 Model 160

Interface converter Interface converter Interface converter

AT&T 301/303 to V.35 RS-232-C to neutral AT&T 301/303 to

current loop RS-232-C

Governed by DCE/DTE Governed by DCE/DTE Governed by DCE/DTE

- - -

- - -

- - -

1 V.35, 1 301/303 See comments R5-232-C or A T& T 301/303 Any with AT&T 301/303 Any with RS-232-C Any with AT&T 301/303

interface interface

Direct Direct Direct

- - -

1,225 315 750

Vendor Vendor Vendor

30 days 30 days 30 days

June 1976 June 1976 June 1976

- - -

Permits data communica- Allows RS-232-C Converts AT&T 301/303 tions users to change interface equipment to on terminal side to wideband services from be connected to Teletype RS-232-C on communica- AT&T 301/303 modem equipment with neutral tions side

interface to DDS V.35 current loop; can also interface be used as a line driver

MAY 1987 © 1987 DATAPRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA

REPRODUCTION PROHIBITED-FOR REPRINTS, CALL 1-800-328-2776

Avanti Communications Model 120 Interface converter

V.35 to AT&T 301/303

Governed by DCE/DTE

-

- -

1 V.35, 1 301/303 Any with V.35 interface

Direct

-

1,150 Vendor 30 days June 1976

-

Interfaces DTE with V.35 to AT&T 301/303 modems

Avanti Communications Model 170 Interface converter

V.35 to RS-232-C

Governed by DCE/DTE

- -

-

V.35, RS-232-C Any with V.35 interface

Direct

-

550 Vendor 30 days June 1976

-

Converts V.35 on termi- nal side to RS-232-C on the communications side

(2)

C23-010-502 Protocol Conversion Systems

MANUFACTURER

a.

MODEL

DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFIC A TIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Intarface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER

a.

MODEL

DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

ComData Com/Tech Systems Dataprobe

ASC-100 RTS/Emulator A302 DR-10

Async/sync converter Async/sync converter Protocol converter

Asynchronous to Full to half duplex; .ASCII to Poll Select synchronous protocol async to sync

6oo-19.2K 9600 9600

Async/sync Asynchronous Async/sync

Full duplex Half/full duplex Half/full duplex ASCII, EBCDIC, Wang 5-9 level codes ASCII, Baudot

RS-232-C RS-232-C 2 RS-232-C, 1

current loop

Contact vendor Any

-

-

Direct, dial-up Leased line

-

None Self-test

247 390-450 750

Vendor Factory

-

Contact vendor Two weeks

-

Info. not available 1978 1983

Info. not available

-

250

Nominal async and sync Includes 64 or 128 Custom programs rates must match; unit character buffer and

has 48-bit buffer that break signalling allows maximum packed

block length of 24K 10-bit charac. at .02%

speed difference

Datatel

Dataprobe DCP Series DCC

DR-7 Interface Converters ECS-10

Interface converter Interface converters Interface converter

RS-232-C/RS-422 to RS-232-C to V.35, RS-422 RS-232-C to 20/60 mA V.35 & MIL-188; V.35 to

RS-422

56K bps Dev. depend. 9600

Synchronous Async/sync Asynchronous

Full duplex Half/full duplex Full duplex

All

-

All

RS-232-C/RS-422 to RS-232-C, V.35, RS-422, RS-232-C, current loop

V.35 MIL-188

Any RS-232-C DTE/DCE

-

Direct Direct Direct

Status LEDs Front-panel LEDs moni- Manual Tx/Rx data and clock

and DCE or DTE connec- tion

350 300-400 (qt. dis availt 125

-

Vendor Factory

10 days 30 days Stock to 30 days

1982 August 1984; May 1985 1977

350 Info. not available 2,500

-

DCP Series converters Optical isolation for

provide connection host/terminal protection and conversion from high noise immunity;

modem to terminal and multidrop cap.; active/

from terminal to modem; passive interfaGe to all units operate bi- other 20/60 mA devices;

directionally long line driving cap.

© 1987 DAT APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED-FOR REPRINTS, CALL 1-800-328-2776

Dataprobe DR-15

~I

Code and speed converter

ASCII-Baudot-EBCDIC

9600 Async/sync Half/full duplex ASCII, Baudot RS-232-C, current loop

-

Leased line Self-test

750

- -

1983 75

Custom programs

DCC ECS-20 Interface converter

RS-232-C to 20 mA current loop

9600 Asynchronous Full duplex All

RS-232-C, current loop

-

Direct

Status LEDs, manual

125 Factory

Stock to 30 days' 1985

Approximately 190 Optical isolation; high noise immunity; long line driv.cap;interfaces 20 mA single & multidrop circuits; control chan.

in ea. direction; LED data/control indicators

MAY 1987

(3)

(

MANUFACTURER &. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER &. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Putchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Gandalf Data Gandalf Data Gandalf Data

IFC 201/202/203/204 IFC 205/206 IFC 207/208/209 Interface converters Interface converters I nterface converters

RS-232-C to RS-422 or RS-232-C to V.5 and RS-232-C to A T& T 300 &

RS-423 and vice versa vice versa (dep. on vice versa; AT&T 300 to

(dep. on model) model) V.35 (dep. on model)

20K bps; 2M bps (RS-422) 20K 48K

Asynchronous Asynchronous Asynchronous

Full duplex Full duplex Full duplex

All All All

RS-232-C and RS-422 or RS-232-C and V.3S RS-232-C and A T& T 300 or

RS-423 dep. on model V.35 (dep. on model)

DCE/DTE DCE/DTE DCE/DTE

Direct Direct Direct

None None None

425 425 400 (207/208); 650 (209)

- - -

15 days 15 days 15 days

April 1982 April 1982 April 1982

Info. not available Info. not available Info. not available All units equipped with All units equipped with All units equipped with self-contained power self-contained power self-contained power supplies and appropriate supplies and appropriate supplies and appropriate cables and connectors cables and connectors cables and connectors

General DataComm

General DataComm GDC Interface INCAA Datacom B.V.

ASC-1 Converter Series PIT-BSC-0001

Async/sync converter Interface converter Interface, async/sync, strin9, flow-control, speed, and code convertr Asynchronous to RS-422 to RS-232-C, Level 1 (OS I) converter synchronous RS-422 to V.35, and

RS-232-C to V.35

9600

-

19.2K

Async/sync Async/sync Async/sync

Half/full duplex,simplex Half/full duplex Half/full duplex

ASCII ASCII ASCII/EBCDIC/Baudot, all

RS-232-C, V.24, V.28 RS-422, RS-232-C, V.35 RS-232-C, V.24, V.28

Asynchronous terminal DTE/DCE Undefinable

Direct, dial-up Direct, dial-up Direct, dial-up, leased lines

Loopback test (sync) Power LED Status LEDs, remote tests, set-up test

295 See comments 1,200

Factory Factory Contact vendor

30 days 30 days Contact vendor

1981 1985

-

1000

- -

Automatically and dy- GDC 422-232 model is

-

namically manages flow $225; 422-V.35 model is of data to avoid buffer $295; and 232-V.35 overflow; accepts up to model is $475.

2 percent continuous All devices perform a async input bidirectional conversion

MAY 1987 © 1987 DATAPRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA

REPRODUCTION PROHIBITED-FOR REPRINTS, CALL 1-800-328-2776

Gandalf Data AIM 2086 Subscriber interface model for data PBXs Speed, flow control, parity, character format

-

Asynchronous Full duplex ASCII RS-232-C Async DTE or DCE equipment Direct

Status LEDs, remote tests, loopbacks

Contact vendor Vendor 15 days

- -

Subscriber interface module for data PBX;

microprocessor-based unit

JBM Electronics ALD Interface converter

RS-232-C to RS-422

lOOK Asynchronous Full duplex ASCII RS-232-C Not applicable

Direct

Status LEDs, loop backs

135 Factory 7 days ARO 1984 3,000

Compact unit signal regeneration for RS-232-C connection

(4)

C23-010-504 Protocol Conversion Systems

MANUFACTURER & MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER & MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Method Systems Nu Data Nu Data

PCT-100 701A 722

Code and speed Code and speed Code and speed converter, data converter converter, interface

manipulation converter, ser/par

-

Current loop to RS-232-C

-

19.2K 2400 19.2K

Asynchronous Asynchronous Asynchronous

Full duplex Half duplex Half/full duplex

ASCII, Baudot, EBCDIC' ASCII, Baudot ASCII, Baudot, EBCDIC RS-232-C RS-232-C, V.24, V.28, RS-232-C, V.24, V.28,

current loop parallel Most asyne machines Any async computer port

-

-

Direct, leased lines, Direct, leased lines

Telex

Not applicable Status LEDs Status LEDs,

programmable

495 395 680

Factory Factory Factory

From stock Stock Stock

1983 1983 January 1986

Approximately 2,000 250 150

Programmable Communi- Simplex Baudot to ASCII Multifunctional unit cations Translator code/speed conversion available with many

allows software/hardware standard or custom-

interfaces to be made programmed features

compatible and can provide system-level enhancements

Quasitronics

Asynchronous Protocol Quasitronics Quasitronics

Converter Q-1108 Q1488C/S

Bidirectional code Interface converter Interface converter conversion

ASCII to EBCDIC; ASCII BCD parallel to RS-232-C RS-232-C to IEEE 488 to Baudot

19.2K 9600 9600

Asynchronous Asynchronous Asynchronous

Half/full duplex Half/full duplex Full duplex

ASCII, EBCDIC, Baudot ASCII ASCII

RS-232-C R5-232-C, BCD Parallel RS-232-C, IEEE 488

Async ASCII terminals

- -

and peripherals

Direct Direct Direct

Front-panel LEDs Status LEDs Status LEDs

Contact vendor 920 1,159 to 1,289

Vendor Vendor Vendor

-

60 days 60 days

First quarter 1986 1982 1982

Info. not available Over 500 Over 500

Contains modular firm- Converts 8 digits of Provides either slave or ware, selected through BCD parallel to RS-232-C controller operation on internal switch settings; ASCII code IEEE-488 bus. Slave other stan. features in. unit can either be a

flow control conv. bwt. talker or listener

X-on/X-off, RTS/CTS, DTR/DSR, and ENQ/ ACK

© 1987 DA T APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED-FOR REPRINTS, CALL 1-800-328-2776

Nu Data T26 Series Interface converter, code and speed converter PSDN to RS-232-C

2400 Asynchronous Half/full duplex ASCII, Baudot RS-232-C, V.24, V.28 Any asyne computer port

Direct, leased lines, Telex, DDD Status LEDs

From 980 Factory Stock 1982 5,000

Provides computer access to all Telex and DDD networks

Quasitronics 04011 and Q-4015 Interface converter

RS-232-C to Centronics parallel or Data Products parallel

9600 Asynchronous Half duplex ASCII, EBCDIC RS-232-C, Centronics parallel

-

Direct

-

325 Vendor 60 days

1983 Over 2,000

Will convert to and from either Centronics parallel or Data Products parallel inter- faces to or from RS-232-C

MAY 1987

(5)

(

- -

~

(

{/

MANUFACTURER 8r. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER 8r. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFIC A TIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Tekelec T.A.N.S. 1000,2000,

Shaffstall 3000,4000,6000,7000, Telebyte Technology

5000XT 8000, and 9000 Model 61

Interface converter Async/ sync converter Converter (cable)

- _.

RS-232-C to Coaxial

9600

-

9600

Async/sync Async/sync Asynchronous

Half duplex Half/full duplex Full duplex

ASCII, EBCDIC ASCII, EBCDIC ASCII

RS-232-C RS-232-C, V.24, V.35 RS-232-C

- - -

Direct, dial-up Direct, dial-up, leased Coax

Status LEOs Remote tests, LCD

-

display

14,500+, dep. on options 5,000 to 9,500 75

Vendor's support dept. Vendor Vendor

30 days ARO 30 days 3 days

1986 May 86-UK, Feb 87-US

-

Over 800 280

-

The 5000XT enables the The only communications DTE/DCE switch; Model 61 conversion of word pro- processor on the market derives operating power cessor or PC disks to capable of protocol con- from host by 'stealing' other, formerly incom- version, protocol power from control patible, systems switching, term. & prntr signals

sharing and LAN node connection all in 1 unit

Telebyte Tehcnology Telebyte Technology Telebyte Technology

Models 64/65 Model 66 Model 67

Interface converter Interface converter Interface converter

RS-232-C to current RS-232-C to RS-485 RS-232-C to V.35 loop

9600 38.4K 64K

Asynchronous Asynchronous Async/sync

Half/full duplex Half duplex Full duplex

-

All ASCII

RS-232-C, current loop RS-232-C RS-232-C, V.35

For use with teletypes All

-

or computers providing current loop input

Direct Direct

-

-

LEOs

-

80/100 120 195

Telebyte

-

Vendor

14 days

-

30 days

-

January 1986

-

3,000

- -

Switch sel. DCE/DTE Offers programmable 67-1 RS-232=DTE operation; Model 64 contention and line 67-2 RS-232=DCE host powered, Model selection; implements

65 self powered low-cost LAN by inter- facing RS-232-C equipment with networks based on new RS-485 standard

MAY 1987 © 1987 DA T APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA

REPRODUCTION PROHIBITED-FOR REPRINTS, CALL 1-800-328-2776

Telebyte Technology Series 63 Interface converter

RS-232-C to RS-422

19.2K Asynchronous Half/full duplex

-

RS-232-C

-

Direct

-

98/host; 126/self Telebyte

14 days

-

4000

Provides up to 4000 ft.

transmission for data and three control sig- nals

Telebyte Technology Model 69-1 Interface converter

RS-232-C to MIL-STD-188C

19.2K Asynchronous Full duplex ASCII RS-232-C

-

-

-

100 Vendor 30 days

- -

The Series 69 converters provide a hardware con- version between conven- tiona I RS-232 based equipment and systems employing a version of MIL-STD-188

~

(6)

C23~01

0-506 Protocol Conversion Systems

MANUFACTURER 8t MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER 8t MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND A V AILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Telebyte Technology Telebyte Technology Telebyte Technology

Model 69-6 Model 78 121 Dual Converter

Interface converter Interface converter Interface converter

RS--232-C to MIL-STD-l00 RS-232-C to current RS--232-C to RS--422 loop (dual)

19.2K 9600 38.4K

Synchronous Asynchronous Asynchronous

Full duplex Half/full duplex Full duplex

ASCII, EBCDIC All ASCII, EBCDIC

RS-232-C 2 RS-232-C; 2 RS--232-C

current loop

- - -

-

Direct Leased lines

-

Loopback, LEDs Status LEDs, loopbacks

350 195 75

Vendor

-

Vendor

30 days 5 days 5 days

-

February 1983 June 1986

- - -

-

Fourteen Model 78s may Rack-mounted unit

be housed in 76-2 card cage occupying 514-inch of rack space

Teleprocessing Products Teleprocessing Products Teleprocessing Products

TP-200M TP-201 TP-300

Asyncjsync converter Asyncjsync converter Interface converter

Async data to sync for Async term or compo RS-232-C to current op. with modem or DSU to sync modem or DDS AT&T 303

110 to 9600 1200 to 9600 9600

Async/sync Asyncjsync Asyncjsync

Half/full duplex Half jfull duplex, simplex Half/full duplex

ASCII ASCII All

RS-232-C RS-232-C 1 RS-232-C, current loop

Any aaync device with Any async device with Any modem or DTE with RS-232-C interface RS-232-C interface RS-232-C or AT&T 303

interface

Dial-up Dial-up Direct

Status LEDs, remote Loopbacks Status LEDs tests

Contact vendor Contact vendor Contact vendor

Vendor Vendor Vendor

30 days 30 days Stock

1981 1984 1978

500 1,000 200

With async modems Suitable for polled, Designed as universal TP-200M offers speed- switched, or dedicated adapter; can provide matching and error systems patching and monitoring

correction capability in network

control centers

© 1987 DA T APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED-FOR REPRINTS, CALL 1-800-328~2776

. / Teleprocessing Products

TP-200

\~)

Async/sync converter

8-bit ASCII or 7 -bit IBM async to sync

75 to 19.2K Async/sync

Half/full duplex,simplex ASCII

RS-232-C

Any async device with RS-232-C interface Dial-up

Loopbacks

Contact vendor Vendor 30 days 1979 2,000

Suitable for polled, switched, or dedicated systems; allows device trans. ASCII or IBM data to operate with sync modem

Teleprocessing Products TP-350 Interface converter

RS-232-C to V.35

9600 Asyncjsync Half/full duplex All

RS-232-C, V.35 Any modem or DTE with RS-232-C or V.35 inter- face

Direct Status LEDs

Contact vendor Vendor Stock 1978 500

Provides bidirectional data and control sig-

nal conversion for

( \

adapting V.35 and

RS-232-C interfaces

L

MAY 1987

(7)

(

(

MANUFACTURER 8. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission. in bps Synchronization

Transmission mode Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Code, Speed, Interface, and Async/Sync Converters

VIR VIR VIR

MIU-V.35 MIU-303 MIU-303/V.35

Interface converter Interface converter Interface converter

V.35 to RS-232-C RS-232-C to AT&T 303 V.35 to AT&T 303

230.4K 230.4K

-

Async/sync Async/sync Asynchronous

Half/full duplex Half/full duplex Half/full duplex ASCII, Baudot, EBCDIC ASCII, Baudot, EBCDIC ASCII, Baudot, EBCDIC RS-232-C, V.35 RS-232-C, AT&T 303 V.35, AT&T 303 Any RS-232-C, V.35 All RS-232-C, AT&T 303 All V.35, AT&T 303

Direct, dial-up or Direct, dial-up or Direct, dial-up or

leased lines leased lines leased lines

Status LEDs Status LEDs Status LEDs

680 680 610

Vendor Vendor Vendor

Stock Stock Stock

Date of first comm. delivery of this model

- - -

Number installed to date COMMENTS

MAY 1987

- - -

RS-232-C monitor port, RS-232-C monitor port, RS-232-C monitor POrt, DTE/DCE switches, DTE/DCE switches, rackmount or standalone rackmount or standalone rackmount or standalone versions available versions available versions available

© 1987 DATAPRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED-FOR REPRINTS, CALL 1-800-328-2776

Wall Data CPX Port Expander Code and speed converter

Sync RS-232-C-multiple sync RS-232-C

9600 Synchronous Half/full duplex EBCDIC RS-232-C

IBM PU type 2.X (3274, 3770, etc.)

Direct, dial-up, leased Status LEDs, remote tests

4,495 to 5,995 Vendor at factory 30 days November 1986 20

Not only does CPX expand the number of 37X5 front-end ports, but it also allows for dial-in connection of 3274-type controller with security

(8)

~ I

(9)

MANUFACTURER lit MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND A V AILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER lit MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and AsyncjSync Converters

Avanti Communications Avanti Communications Avanti Communications

Model 100 Model1tO Model 120

Interface converter Interface converter Interface converter

RS-232-C to V.35 RS-232-Cto AT&T 301/303 V.35 to AT&T 301/303

current current loop

Governed by DCE/DTE Governed by DCE/DTE Governed by DCE/DTE

- - -

- - -

- - -

- - -

1 V.35 (DCE). 1 1 301/303, 1 1 V.35, 1 301/303

RS-232-C RS-232-C

Any RS-232-C Any RS-232-C Any with V.35 interface

Direct Direct Direct

- - -

550 1,000 1,150

Vendor Vendor Vendor

30 30 30 days

June 1976 June 1976 June 1976

- - -

Designed to interface Interfaces DTE with Interfaces DTE with DTE with RS-232-C in- RS-232-C to DCE with V.35 to AT&T 301/303 terface to DCE with current loop; converter modems

V.35; into converter kit incl. one six-foot kit incl. one six-foot cable

cable

Avanti Communications Avanti Communications Avanti Communications

Model 140 Model 160 Modelt70

Interface converter Interface converter Interface converter

RS-232-C to neutral AT&T 301/303 current V.35 to R5-232-C current loop interface to RS-232-C

Governed by DCE/DTE Governed by DCE/DTE Governed by DCE/DTE

- - -

- - -

- - -

- - -

See comments RS-232-Cor AT&T 301/303 V.35, RS-232-C Any with RS-232-C Any with AT&T 301/303 Any with V.35 interface

interface

Direct Direct Direct

- - -

315 750 550

Vendor Vendor Vendor

30 days 30 days 30 days

June 1976 June 1976 June 1976

- - -

Allows RS-232-C Converts AT&T 301/303 Converts V.35 on termi- interface equipment to on terminal side to nal side to RS-232-C on be connected to Teletype RS-232-C on communica- the communications side equipment with neutral tions side

current loop; can also be used as a line driver

MAY 1986

©

1986 DAT APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA

REPRODUCTION PROHIBITED

Systems

Avanti Communications Modelt30 Interface converter

AT&T 301/303 to V.35

Governed by DCE/DTE

- - - -

1 V.35, 1 301/303 Any with AT&T 301/303 interface

Direct

-

1,225 Vendor 30 days June 1976

-

Permits data communica- tions users to change wideband services from AT&T 301/303 modem interface to DDS V.35 interface

ComjTech Systems RTS/Emulator A302 Transmission mode con- verter

Full to half duplex;

async to sync

9600 Asynchronous Half/full duplex Asynchronous 5-9 level codes RS-232-C Any

Direct, dial-up None

390-450 Factory Two weeks

1978

-

Includes 64 or 128 character buffer and break Signalling

(10)

C23-010-502 Protocol Conversion Systems

MANUFACTURER

a.

MODEL

DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER

a.

MODEL

DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Com Data Dataprobe Dataprobe

ASC-100 DR-7 DR-10

Async/sync converter Interface converter Protocol converter

Asynchronous to RS-232-C/RS-422 ASCII to Poll/Select synchronous protocol to V.35

600-19.2K 56K bps 9600

Async/sync Synchronous Sync/async

Full duplex Full duplex Half/full duplex

Async/sync All TTY, 83B3

ASCII, EBCDIC, Wang All ASCII, Baudot

RS-232-C R5-232-C/RS-422to 2 RS-232-C, 1

V.35 current loop

Contact vendor Any RS-232-C

-

-

Direct Leased line

-

Status LEOs Self-test

247 350 750

Vendor

- -

Contact vendor 10 days

-

Info. not available 1982 1983

Info. not available 350 250

Nominal async and sync Custom programs

rates must match; unit has 48-bit buffer that allows maximum packed block length of 24K 10-bit charac. at .02%

speed difference

Datatel

DCP Series DCC/Duraeom Corporation DCC/Duraeom Corporation

I nterfaee Converters EC5-1 0 EC5-20

Interface converters Interface converter Interface converter

RS-232-C to V.35, RS-422 RS-232-C to 20/60 mA R5-232-C to 20 rnA

& MIL-188; V.35 to current loop current loop RS-422

Dev. depend. 9600 (2 miles) 9600 (2 miles)

Async/sync Asynchronous Asynchronous

Half/full duplex Half/full duplex Half/full duplex

Asynchronous Asynchronous Asynchronous

-

Any Any

RS-232-C, V.35, RS-422, 1 RS-232-C, 1 20/60 1 RS-232-C, 1 20 mA

MIL-188 mA current loop current loop

DTE/DCE

- -

Direct Metallic path Metallic path

Front-panel LEOs moni- Manual loopback tests Manual loopback, LEOs on

T x/Rx data and clock data/control lines

and DCE or DTE connec- tion

300-400 (qt. dis avail) 99 (Oty. 1) 125

Vendor Factory service Factory service

30 days Stock to 30 days Stock to 30 days

August 1984; May 1985 1977 1985

Info. not available 2400

-

DCP Series converters Optical isolation for Optical isolation; high provide connection host/terminal protection noise immunity; long and conversion from high noise immunity; line driv.cap;interfaces modem to terminal and multidrop cap.; active/ 20 mA single & multidrop from terminal to modem; passive interface to circuits; control chan.

all units operate bi- other 20/60 mA devices; in ea. direction; LED directionally long line driving cap. data & control In. indic

©

1986 OAT APRO RESEARCH CORPORATION. DELRAN. NJ 08075 USA REPRODUCTION PROHIBITED

Dataprobe DR-15 Code & Speed converter

ASCII-Baudot-EBCDIC

9600 Sync/async Half/full duplex TTY, 83B3 ASCII, Baudot RS-232-C, current loop

-

Leased line Self-test

-

750

-

1983 75

Custom programs

Gandalf Data, Ine.

IFC 201/202/203/204 Interface converters

RS-232-C to RS-422 or RS-423 and vice versa (dep. on model)

20K bpI!; 2M bps (RS-422) Asynchronous

Full duplex

-

All

RS-232-C and RS-422 or RS-423 dep. on model DCE/DTE

Direct None

425

-

30 days April 1982 Info. not available All units equipped with self-contained power supplies and appropriate cables and connectors

MAY 1986

(11)

( "'"

/

MANUFACTURER

lit

MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILA81L1TY Purchase. $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER

lit

MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission. in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase. $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Gandalf Data. Inc. Gandalf Data. Inc. General DataComm

IFC 205/206 IFC 207/208/209 ASC-1

Interface converters Interface converters Async/sync converter

RS-232-C to V.5 and RS-232-C to AT&T 300

&

Asynchronous to vice versa (dep. on vice versa; AT&T 300 to synchronous

model) V.35 (dep. on model)

20K bps 48K bps (V.35) 9600

Asynchronous Asynchronous Async/sync

Full duplex Full duplex Half/full duplex.simplex

- - -

All All ASCII

RS-232-C and V.35 RS-232-C and AT&T 300 or R5-232-C. V.24. V.28 V.35 (dep. on model)

DCE/DTE DCE/DTE Asynchronous terminal

Direct Direct Direct. dial-up

None None Loopback test (sync)

425 400 (207/208); 650 (2091 295

- -

Factory

30 days 30 days 30 days

April 1982 April 1982 1981

Info. not available Info. not available 1000

All units equipped with All units equipped with Automatically and dy- self-contained power self-contained power namically manages flow supplies and appropriate supplies and appropriate of data to avoid buffer cables and connectors cables and connectors overflow; accepts up to

2 percent continuous async input

Quasitronics. Inc.

Asynchronous Protocol Remark Datacom Remark Datacom

Converter Models 64/65 Series 63

Bidirectional code Interface converter Interface converter conversion

ASCII to EBCDIC; ASCII RS-232-C to current RS-232-C to R5-422

to Baudot loop

19.2K 9600 19.2K

Asynchronous Asynchronous Asynchronous

Half/full duplex Half/full duplex Half/full duplex

Asynchronous

- -

ASCII. E8CDIC. Baudot

- -

R5-232-C RS-232-C. current loop RS-232-C

Async ASCII terminals For use with teletypes

-

and peripherals or computers providing current loop input

Direct Direct Direct

Front-panel LEOs

- -

Contact vendor 80/100 98/host; 126/self

Vendor Telebyte Telebyte

-

14 days 14 days

First quarter 1986

- -

Info. not available 3000 4000

Contains modular firm- Switch sel. DCE/DTE Provides up to 4000 ft.

ware. selected through operation; Model 64 transmission for data internal switch settings; host powered, Model and three control sig- other stan. features in. 65 self powered nals

flow control conv. bwt.

X-on/X-off. RTS/CTS.

DTR/DSR. and ENQ/ ACK

MAY 1986 © 1986 DATAPRO RESEARCH CORPORATION. DELRAN. NJ 08075 USA REPRODUCTION PROHIBITED

Systems

General DataComm GDC Interface Converter Series Interface converter

RS-422 to RS-232-C, RS-422 to V.35, and RS-232-C to V.35

Async/sync Half/full duplex

-

ASCII

RS-422. RS-232-C. V.35 DTE/DCE

Direct. dial-up Power LED

See comments Factory 30 days 1985

-

GDC 422-232 model is

$225; 422-V.35 model is

$295; and 232-V.35 model is $475.

All devices perform a bidirectional conversion

Telebyte Technology Model 78 Interface converter

R5-232-C to current loop (duall

9600 bps Asynchronous Half/full duplex X-on/X-off All

2 RS-232-C; 2 current loop

-

Direct

Loopback and LEDs

-

195 5 days February 1983

-

Fourteen Model 78s may be housed in 76-2 card cage occupying 514-inch of rack space

(12)

C23-010-504 Protocol Conversion Systems

Code, Speed, Interface, and Async/Sync Converters

~

",-

Teleprocessing Teleprocessing Teleprocessing

Telebyte Technology Products. Inc. Products. Inc. Products. Inc.

"'--

MANUFACTURER 8r. MODEL Model 66 TP-350 TP-300 TP-200

DEVICE TYPE Interface converter, Interface converter Interface converter Sync/async conv!'rter

CONVERSION PERFORMED ' RS-232-C to RS-485 RS-232-C to V.35 RS-232-C to current 8-bit ASCII or 7 -bit AT&T 303 IBM async to sync TRANSMISSION SPECIFICATIONS

Maximum transmission. in bps 38.4K bps 9600 9600 75 to 19.2K

Synchronization Asynchronous Async/sync Async/sync Async/sync

Transmission mode Half duplex Half/full duplex Half/full duplex Half/full duplex.simplex

Protocols supported X-on/X-off

- - -

Codes supported All All All ASCII

Interface RS-232-C 1 RS-232-C and 1 1 RS-232-C and 1 RS-232-C

V.35 current

SPECIFIC DEVICES SUPPORTED All Any modem or DTE with Any modem or DTE with Any async device with RS-232-C or V.35 inter- RS-232-C or AT&T 303 RS-232-C interface

face interface

CONNECTIONS SUPPORTED Direct Direct Direct Dial-up

DIAGNOSTICS LEDs Status LEDs Status LEDs Loopback switch

PRICING AND AVAILABILITY

Purchase. $ 120 Contact vendor Contact vendor Contact vendor

Serviced by Vendor Vendor Vendor

Availability

-

Stock Stock 30 days

Date of first comm. delivery of this model January 1986 1978 1978 1979

Number installed to date

-

500 200 2000

COMMENTS Offers pr09rammable Provides bidirectional Desi9ned as universal Suitable for polled.

contention and line data and control sig- adapter; can provide switched. or dedicated selection; implements nal conversion for patching and monitoring systems; allows device low-cost LAN by inter- adapting V.35 and capability in network trans. ASCII or IBM facing RS-232-C equipment RS-232-C interfaces control centers data to operate with

with networks based on sync modem

new RS-485 standard

Teleprocessing Teleprocessing

Products. Inc. Products. Inc. Universal Data Systems

MANUFACTURER 8r. MODEL TP-201 TP-200M 210A/S-P

DEVICE TYPE Sync/async converter Async/sync converter Async/sync converter

CONVERSION PERFORMED Async term or compo Async data to sync for Allows async. terminals to sync modem or DDS op. with modem or DSU to communicate via

sync. modems TRANSMISSION SPECIFICATIONS

Maximum transmission. in bps 1200 to 9600 110 to 9600 1200 to 9600 bps

Synchronization Async/sync Async/sync Async/sync

Transmission mode Half/full duplex. simplex Half/full duplex Half/full duplex

Protocols supported

- -

ASCII

Codes supported ASCII ASCII All

Interface RS-232-C RS-232-C RS-232-C

SPECIFIC DEVICES SUPPORTED Any async device with Any async device with Asynchronous terminals RS-232-C interface RS-232-C interface

CONNECTIONS SUPPORTED Dial-up Dial-up Direct

DIAGNOSTICS Loopback switch Status LEDs. remote

-

test

PRICING AND AVAILABILITY

Purchase. $ Contact vendor Contact vendor Contact vendor

Serviced by Vendor Vendor

-

Availability 30 days 30 days 30 days

Date of first comm. delivery of this model 1984 1981 Info. not available

Number installed to date 1000 500 Info. not available

COMMENTS Suitable for polled. With async modems Operates with 7. 8. or

(

switched. or dedicated TP-200M offers speed- 9 bits per character

systems matching and error- code. Implemented with ~

correction LSI circuitry

~---~---~---~---~---~. © 1986 DATAPRO RESEARCH CORPORATION. DELRAN. NJ 08075 USA REPRODUCTION PROHIBITED

MAY 1986

(13)

(

(

MANUFACTURER 8. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFIC A nONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAilABILITY Purchase, $

Serviced by Availability

Date offirst comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER 8. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAilABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery ofthis model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Avanti Communications Avanti Communications Avanti Communications

Model 100 Model 110 Model 120

Interface converter Interface converter Interface converter

RS-232-C to V.35 RS-232-C to A T& T 301/30 V.35 to AT&T 301/303

current current loop

Governed by DCE/DTE Governed by DCE/DTE Governed by DCE/DTE

- - -

- - -

- - -

- - -

One V.35 (DCE), one One 301/303, one One V.35, one 301/303

RS-232-C R5-232-C

Any RS-232-C Any RS-232-C Any with V.35 interface

Direct Direct Direct

- - -

550 1,000 1,150

Vendor Vendor Vendor

30 30 30 days

June 1976 June 1976 June 1976

- - -

Designed to interface Interfaces DTE with Interfaces DTE with DTE with RS-232-C in- RS-232-C to DCE with V.35 to AT&T 301/303 terface to DCE with current loop; converter modems

V.35; into converter kit incl. one six-foot kit incl. one six-foot cable

cable

Avanti Communications Avanti Communications Avanti Communications

Model 140 Model 160 Model 170

Interface converter Interface converter Interface converter

RS-232-C to neutral AT&T 301/303 current V.35 to RS-232-C current loop interface to RS-232-C

Governed by DCE/DTE Governed by DCE/DTE Governed by DeE/DTE

- - -

- - -

- - -

- - -

See comments RS-232-C or A T& T 301/30 V.35, RS-232-C Any with RS-232-C Any with AT&T 301/303 Any with V.35 interface

interface

Direct Direct Direct

- - -

315 750 550

Vendor Vendor Vendor

30 days 30 days 30 days

June 1976 June 1976 June 1976

- - -

Allows RS-232-C Converts A T& T 301/303 Converts V.35 on termi- interface equipment to on terminal side to nal side to RS-232-C on be connected to Teletype R5-232-C on communica- the communications side equipment with neutral tions side

current loop; can also be used as a line driver

MAY 1985 © 1985 OAT APRO RESEARCH CORPORATION, DELRAN, NJ08075 USA REPRODUCTION PROHIBITED

Terminal Controllers

Avanti Communications Model 130 Interface converter

AT&T 301/303 to V.35

Governed by DCE/DTE

- - - -

One V.35, one 301/303 Any with AT&T 301/303 interface

Direct

-

1,225 Vendor 30 days June 1976

-

Permits data communica- tions users to change wideband services from A T& T 301/303 modem interface to DDS V.35 interface

Com/Tech Systems RTS/Eri1ulator A302 Transmission mode. con- verter

Full to half duplex;

async to sync

9600 Asynchronous Half/full duplex Asynchronous Five to nine level codes RS-232-C

Any

Direct, dial-up None

390-450 Factory Two weeks

1978

-

Includes 64 or 128 character buffer and break signalling

(14)

C23-010-502 Conversion Systems/

Terminal Controllers

MANUFACTURER 8. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER 8. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND A V AILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and AsyncjSync Converters

Dataprobe Dataprobe DCC/Duracom Corporation

DR-10 DR-15 ECS-10

Protocol converter Code & Speed converter Interface converter

ASCII to Poll/Select ASCII-Baudot-EBCDIC RS-232-C to 20/60 mA

9600 9600 9600 (2 miles)

Sync/a sync Sync/async Asynchronous

Half/full duplex Half/full duplex Half/full duplex

TTY, 83B3 TTY, 83B3 Asynchronous

ASCII, Baudot ASCII, Baudot Any

Two RS-232-C, one RS-232-C, current loop One RS-232-C, one 20/60

current loop mA current loop

-

-

-

leased line leased line metallic path

Self-test Self-test Manual loop back tests

750 750 99 (Qty. 1)

- -

Factory service

- -

Stock to 30 days

1983 1983 1977

250 75 2400

Custom programs Custom programs Optical isolation for host/terminal protection high noise immunity;

mutlidrop cap.; active/

passive interface to other 20/60 mA devices;

long line driving cap.

General DataComm Remark Datacom Remark Datacom

ASC-1 Models 64/65 Series 63

Async/sync converter Interface converter Interface converter

Asynchronous to RS-232-C to current RS-232-C to RS-422

synchronous loop

9600 9600 19.2K

Async/sync Asynchronous Asynchronous

Half/full duplex,simplex Half/full duplex Half/full duplex

- - -

ASCII

- -

RS-232-C, V.24, V.28 RS-232-C, current loop RS-232-C Asynchronous terminal For use with teletypes

-

or computers providing current loop input

Direct, dial-up Direct Direct

Loopback test (sync)

- -

295 80/100 98/host; 126/self

Factory Telebyte Telebyte

30 days 14 days 14 days

1981

- -

1000 1,000 1,000

Automatically and dy- Switch sel. DCE/DTE Provides up to 4000 ft.

namically manages flow operation; model 64 transmission for data of data to avoid buffer host powered, model and three control sig- overflow; accepts up to 65 self powered nals

2 percent continuous async input

© 1985 DAT APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED

DCC/Duracom Corporation EC5-20 Interface converter

RS-232-C to 20 mA

9600 (2 miles) Asynchronous Half/full duplex Asynchronous Any

One RS-232-C, one 20 mA current loop

-

metallic path

Manual loopback, LEDs on data/control lines

125

Factory service Stock to 30 days 1985

-

Optical isolation; high noise immunity; long line driv.cap;interfaces 20 mA single & multidrop circuits; control chan.

in ea. direction; LED data & control In. indic

Teleprocessing Products, Inc.

TP-350 Interface converter

RS-232-C to V.35

9600 Async/sync Half/full duplex

-

All

One RS-232-C and one V.35

Any modem or DTE with RS-232-C or V.35 inter- face

Direct Status LEDs

Contact vendor Vendor Stock 1978 500

Provides bidirectional data and control sig- nal conversion for adapting V.35 and RS-232-C interfaces

MAY 1985

(15)

MANUFACTURER & MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND A V AILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Teleprocessing Teleprocessing Teleprocessing

Products, Inc. Products, Inc. Products, Inc.

TP-300 TP-200 TP-201

Interface converter Syncjasync converter Syncjasync converter

RS-232-C to current 8-bit ASCII or 7-bit Async term or compo AT&T 303 IBM async to sync to sync modem or DDS

9600 75 to 19.2K 1200 to 9600

Asyncjsync Asyncjsync Asyncjsync

Half jfull duplex Halfjfull duplex,simplex Half jfull duplex,simplex

- - -

All ASCII ASCII

One RS-232-C and one RS-232-C RS-232-C

current

Any modem or DTE with Any async device with Any async device with RS-232-C or AT&T 303 RS-232-C interface RS-232-C interface interface

Direct Dial-up Dial-up

Status LEDs Loopback switch Loopback switch

Contact vendor Contact vendor Contact vendor

Vendor Vendor Vendor

Stock 30 days 30 days

1978 1979 1984

200 2000 1000

Designed as universal Suitable for polled, Suitable for polled, adapter; can provide switched, or dedicated switched, or dedicated patching and monitoring systems; allows device systems

capability in network trans. ASCII or IBM control centers data to operate with

sync modem

MAY 1985 © 1985 DATAPRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED

Terminal Controllers

Teleprocessing Products, Inc.

TP-200M Asyncjsync converter

Async data to sync for op. with modem or DSU

110 to 9600 Asyncjsync Half jfull duplex

-

ASCII RS-232-C

Any async device with RS-232-C interface Dial-up

Status LEDs, remote test

Contact vendor Vendor 30 days

1981 500

With async modems TP-200M offers speed- matching and error- correction

(16)
(17)

('

(

MANUFACTURER 8. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND A V AILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER 8. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND A V AILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Async/Sync Converters

Avanti Communications Avanti Communications Avanti Communications

Model 100 Model 110 Model 120

Interface converter Interface converter Interface converter

RS-232-C or MIL-188C RS-232-C or MIL-188C V.35 to 301/303 current to V.35 to A T& T 301/303 current loop

Governed by DCE/DTE Governed by DCE/DTE Governed by DCE/DTE

- - -

- - -

- - -

- - -

One V.35 (DCE), one One 301/303, one One V.35, one 301/303 RS-232-C or MIL-188C' R8-232-C or MIL-188C

Any RS-232-C or Any RS-232-C or Any with V.35 interface

MIL-188C MIL-188C

Direct Direct Direct

- - -

550 1,000 1,150

Vendor Vendor Vendor

30 3D 30 days

June 1976 June 1976 June 1976

- - -

Designed to interface Interfaces DTE with Interfaces DTE with DTE with RS-232-C in- RS-232-C or MIL-188C V.35 to AT&T 301/303 terface to DCE with to DCE with current modems

V.35; into converter loop; converter kit kit incl. one six-foot incl. one six-foot

cable cable

·Spec. at time of order

Avanti Communications Avanti Communications Avanti Communications

Model 140 Model 150 Model 160

Interface converter Interface converter Interface converter

RS-232-C or MIL-188C RS-232-C to MIL-188C AT&T 301/303 current

to neutral current loop interface to RS-232-C

or MIL-188C Governed by DCE/DTE Governed by DCE/DTE ~overned by DCE/DTE

- -

- - -

- - -

- - -

See comments MIL-188C RS-232-C or MIL-188C,

AT&T 301/303 Any with RS-232-C or Any with RS-232-C Any with AT&T 301/~O3

MIL-188C interface .'

>;"."

Direct Direct Direct

- - -

315 425 750

Vendor Vendor Vendor

30 days 30 days 30 days

June 1976 June 1976 June 1976

- - -

Allows RS-232-Cor Converts AT&T 301/303

MIL-188C interface on terminal side to

equipment to be connect- RS-232-C on communica-

ed to Teletype equip- tions side

ment with neutral curr- ent loop; can also be used as a line driver

JUNE 1984 © 1984 OAT APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED

Terminal Controllers

Avanti Communications Model 130 Interface converter

AT&T 301/303 to V.35

Governed by DCE/DTE

-

- -

-

One V.35, one 301/303 Any with AT&T 301/303 interface

Direct

-

1,225 Vendor 30 days June 1976

-

Permits data communica- tions users to change wideband services from AT&T 301/303 modem interface to DDS V. 35 interface

Avanti Communications Model 170 Interface converter

V.35 to RS-232-C or MIL-188C

Governed by DCE/DTE

- -

- -

V.35, RS-232-C or MIL-188C

Any with V.35 interface

Direct

-

550 Vendor 30 days June 1976

-

Converts Y.as ontermi- nal side to RS-232-C or MIL-18SC on the com- munications side

(18)

C23-01

O-~02

Conversion Systems/

Terminal Controllers

MANUFACTURER S. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPEC/FICA TIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER S. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery ofthis model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Com/Tech Systems Dataprobe Duracom Corporation

RTS/Emulator A302 DR-10/DR-10A EC5-1 0

Transmission mode con- Code and speed con- Interface converter

verter verter

Full to half duplex; ASCII to Baudot, ASCII RS-232-C to 20 mA async to sync to Telex

9600 9600 9600 (2 miles)

Asynchronous Async/sync

-

Half/full duplex Half/full duplex Half/full duplex

Asynchronous RS-232-C, HDLC Asynchronous

Five to nine level codes ASCII, Baudot, EBCDIC

-

RS-232-C Two RS-232-C, one One RS-232-C, one

current loop current loop

Any

- -

Direct, dial-up

- -

None Self-test, dynamic RAM Manual /oopback tests

390-450 750/950 per line 99 (Qty. 1)

Factory

-

Factory service

Two weeks 30 days/90 days Stock to 30 days

1978 January 1983/ April 1984 1977

-

75/10 2000

Includes 64 or 128 System building block;

character buffer and three independent break signalling baud-rate generators;

alarm outputs

Teleprocessing Remark Datacom Remark Datacom Products, Inc.

Models 64/65 Series 63 TP-350

Interface converter Interface converter Interface converter

RS-232-C to current RS-232-C to RS-422 RS-232-C to V.35 loop

To 9600 To 9600 To 9600

Asynchronous Asynchronous Async/sync

Half/full duplex

-

Half/full duplex

- - -

- - -

RS-232-C, current loop RS-232-C One RS-232-C and one V.35

For use with teletypes

-

Any modem or DTE with

or computers providing RS-232-C or V.35 inter-

current loop input face

- -

Direct

- -

Status LEOs

Contact vendor Contact vendor Contact vendor

Vendor Vendor Vendor

- - -

- - -

- - -

Switch sel. DCE/DTE Provides up to 4000 ft. Provides bidirectional operation; model 64 transmission for data data and control sig- host powered, model and three control sig- nal conversion for 65 self powered nals; available as adapting V.35 and

host-powered or self- RS-232-C interfaces powered units

© 1984 DATAPRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED

General DataComm ASC-1 Async/sync converter

Asynchronous to synchronous

9600 Async/sync

Half/full duplex,simplex

-

ASCII

RS-232-C, V.24, V.28 Asynchronous terminal

Direct, dial-up Loopback test (sync)

295 Factory 30 days 1981 1000

Automatically and dy- namically manages flow of data to avoid buffer overflow; accepts up to 2 percent continuous async input

Teleprocessing Products, Inc.

TP-300 Interface converter

RS-232-C to current AT&T 303

To 9600 Async/sync Half/full duplex

- -

One RS-232-C and one current

Any modem or DTE with RS-232-C or A T& T 303 interface

Direct Status LEOs

Contact vendor Vendor

- -

-

Designed as universal adapter; can provide patching and monitoring capability in network control centers

JUNE 1984

(19)

(~

MANUFACTURER S. MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFICATIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase, $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

MANUFACTURER & MODEL DEVICE TYPE

CONVERSION PERFORMED

TRANSMISSION SPECIFIC A TIONS Maximum transmission, in bps Synchronization

Transmission mode Protocols supported Codes supported Interface

SPECIFIC DEVICES SUPPORTED

CONNECTIONS SUPPORTED DIAGNOSTICS

PRICING AND AVAILABILITY Purchase. $

Serviced by Availability

Date of first comm. delivery of this model Number installed to date

COMMENTS

Code, Speed, Interface, and Async/Sync Converters

Teleprocessing Teleprocessing Teleprocessing

Products, Inc. Products, Inc. Products, Inc.

TP-200 TP-201 TP-200M

Sync/async converter Sync/async converter Async/sync converter

B-bit ASCII or 7 -bit Async term or compo Async data to sync for IBM async to sync to sync modem or DDS op. with modem or DSU

75 to 19.2K 1200 to 9600 110 to 9600

Async/sync Async/sync Async/sync

Half/full duplex,simplex Half/full duplex, simplex Half/full duplex

- - -

ASCII

- -

RS-232-C RS-232-C RS-232-C

Any async device with Any async device with

-

RS-232-C interface RS-232-C interface

Dial-up Dial-up

-

Loopback switch Loopback switch Status LEDs, remote test

Contact vendor Contact vendor Contact vendor

Vendor Vendor Vendor

30 days 30 days 30 days

- - -

- - -

Suitable for polled, Suitable for polled, With async modems switched. or dedicated switched. or dedicated TP-200M offers speed- systems; allows device systems matching and error-

trans. ASCII or IBM correction

data to operate with sync modem

Versitron Versitron Versitron

R42DSU R42S Relays

Interface converter Interface converter Interface converter

V.35 to EIA/MIL RS-232-C to 449 or EIA, MIL. TTY, WECO.

MIL-1BB-144 etc.

56K 500K 500K

Synchronous Synchronous

-

Full duplex Full duplex Half/full duplex

- - -

- - -

One V.35. one MIL/EIA One RS-232-C, one Various RS-449 or MIL

Any with V.35 into Any with RS-232-C. 449. Various MIL-1BB-114

Direct Direct Direct

- - -

457 599 122-367

-

Factory Factory

30-60 days 30-60 days 30-60 days

19B2 19B1 1975

200 200 1000

Maximum speed depends Maximum speed depends Forty-four models with on cable length on cable multiple interface

options, some with mUltiple circuits;

requires chassis

JUNE 1984 © 1984 DA T APRO RESEARCH CORPORATION, DELRAN, NJ 08075 USA REPRODUCTION PROHIBITED

Terminal Controllers

Versitron R42M Interface converter

RS-232 to MIL-1BBC

lOOK Async/sync Full duplex

- -

One RS-232-C, one MIL-1BBC

Any with RS-232-C or MIL-1BBC

Direct

-

36B Factory 30-60 days

19B1 500

Phase programmable, rackmount available.

time source selectable;

maximum speed depends on cable length

(20)

Referenzen

ÄHNLICHE DOKUMENTE

The introduction of AT&amp;T's Dataphone Digital Service (DDS) increased the demand for converters because an application that originally used AT&amp;T 301 or 303 modems

This converter comes with a five-foot cable terminated with a DB37P connector for the modem connection, and a rear-panel mounted DB25S connector for the business ma- chine

serialize To execute a parallel construct with a team of threads consisting of only a single thread (which is the master thread for that parallel construct), with serial order

Counter of a Locked Device Adapter. 3-17 Returning the Timeout Value. 3-17 Returning the Data Path Width Value 3-17 Returning Reason for Last Interrupt 3-18 Returning

For both switched and nonswitched lines, the local Displaywriter modem establishes the communications link by sending a continuous transmit carrier signal to the

The JE665 option is a circuit-board assembly added to the JE664 Programmer. It implements exchange of data between the JE664's RAM and an external computer over the

The RS-232C interface is an EIA (Electronic Industries Association) &#34;Recommended Standard&#34; inter- face. It transmits and receives data in serial form, one bit at

This manual is intended as a supplement to the JE664 EPROM Programmer Operation Manual. It describes the operation and programming of the JE665 RS·232C