• Keine Ergebnisse gefunden

Circadian phase (

N/A
N/A
Protected

Academic year: 2022

Aktie "Circadian phase ("

Copied!
23
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Objective methods for estimating chronotype in the field

Debra J. SKENE

Chronobiology

University of Surrey, Guildford, UK

d.skene@surrey.ac.uk

Chronotype

Circadian phase (f) (phi)

Phase of entrainment (Y) (psi) Diurnal preference

(morningness/eveningness)

(2)

Phase: a defined point in the cycle

Biological rhythms: circadian phase

Circadian rhythms

Rajaratnam &Arendt 2001

melatonin

core body temp

subjective alertness

task performance

triacylglycerol

(3)

Phase of entrainment (Y)

Difference between

a given phase of circadian rhythm

e.g., trough of core body temperature, melatonin onset or midpoint of sleep)

and that of the zeitgeber (time cue)

e.g., dawn or mid-dark.

Munich ChronoType Questionnaire - MCTQ

www.euclock.org

Roenneberg & Merrow, 2007

01:00 09:30

MSF = 5.25

(4)

Diurnal preference

Chronotype as a personality trait

Separate morningness from eveningness

Horne and Östberg, 1976

(5)

• Diurnal preference

Horne-Östberg questionnaire (MEQ)

• Phase of entrainment

Munich Chronotype questionnaire (MCTQ;

MCTQshift)

Non-invasive measurement tools

Need a reliable marker of circadian phase of worker

- assess circadian clock timing - optimise timing of chronotherapy

Challenges - Objective measure

(6)

Pineal gland - primary site of melatonin synthesis

Melatonin as a reliable marker of circadian phase

Retina-SCN-PVN-SCG-pineal pathway

SCN rhythmicity drives melatonin rhythm

Entrained to 24 h by light/dark via the retina-RHT pathway

(7)

Melatonin as a reliable marker of circadian phase

• unaffected by:

meals, stress, bathing, sleep

• dim light conditions (< 8 lux)

• exclude drugs

• control posture, exercise

0 10 20 30 40 50 60 70 80

1500 1700 1900 2100 2300 100 300 500 700 900 1100 1300 1500 1700

clock time (h)

plasma melatonin (pg/ml)

acrophase (calculated peak time)

mid-range crossing

25% rise/fall onset/offset

*

*

*

* *

* *

duration

‘biological night’

Markers of the melatonin rhythm

used to characterise the timing of the circadian clock

Arendt & Skene, Sleep Medicine Reviews (2005) 9:25-39

(8)

Benloucif et al., 2007

0 5 10 15 20 25 30 35 40 45

17:00 19:00 20:30 23:00 02:00 05:00 08:00 11:00

0 5 10 15 20 25 30 35 40 45

17:00 19:00 20:30 23:00 02:00 05:00 08:00 11:00

Night 1 Night 2

0 10 20 30 40 50 60 70 80

17:00 18:30 20:00 22:00 01:00 04:00 07:00 10:00

0 10 20 30 40 50 60 70 80

17:00 18:30 20:00 22:00 01:00 04:00 07:00 10:00

Melatonin rhythms - Inter-individual variation - Within individual consistency

Sletten et al., unpublished

pl as m a m el ato ni n (pg /m l)

(9)

Benloucif et al., 2007

RIA and ELISA technology

• Easy to measure plasma, saliva

• Sensitive, specific

• High throughput

• Relatively inexpensive

STOCKGRAND LTD

STOCKGRAND LTD

(10)

Melatonin as a reliable marker of circadian phase

aMT6s as a

reliable marker of melatonin rhythms

• non invasive

• convenient for field studies

Timed urine sampling 4 h (+ overnight) for 48 h

Calculate aMT6s peak (6-sulphatoxymelatonin)

Arendt et al., 1985;

Bojkowski et al., 1987

Melatonin and aMT6s rhythms

(11)

0 200 400 600 800

l l l l l

l l l l l l l l l

l l l l l l l

l l

l l l l

l l

0 10 20 30 40 50 60 70

0 500 1000 1500 2000 2500

l l l l l l l

l l l

l l l l l l l l l

l l

l

l

l l l l 0

20 40 60 80 100 120 140

Clock time (h)

P las m a m el ato ni n (pg /m l)

0 200 400 600 800 1000 1200 1400 1600 1800

l l l l l l

l l l l

l l l l l

l l l

l l

l l l

l l l l l l 0

20 40 60 80 100 120 140 160 180 200

l

0 200 400 600 800 1000 1200 1400

l l l l l

l l

l l l l l

l l l l l

l l

l l l l

l l l l

l 0

20 40 60 80 100 120

Melatonin and aMT6s rhythms

Ur ina ry aM T 6s ( ng /h)

Montagnese et al. unpublished

18 20 22 24 02 04 06 08 10 12 14 16 18 18 20 22 24 02 04 06 08 10 12 14 16 18

18 20 22 24 02 04 06 08 10 12 14 16 18 18 20 22 24 02 04 06 08 10 12 14 16 18

Table 1: Sampling details for measurement of melatonin and 6-sulphatoxymelatonin (aMT6s)

Biological fluid Analyte Sampling procedure Precautions

Blood Melatonin

Collect blood into heparinised tubes. Centrifuge within 15 mins.

Store plasma at -20°C.

Haemolysed plasma and plasma left in plastic pipettes for more than 2-3 minutes may give falsely elevated melatonin levels.

Saliva Melatonin

The best method is to ask subjects to spit into polypropylene tubes. Do not stimulate saliva production.

Store at -20°C.

Salivettes with an untreated cotton plug can be used.

Centrifuge for 15 mins at 3000 rpm. Store at -20°C.

Do not eat within 30 mins of sampling. Rinse mouth with tap water before spitting. Saliva left in plastic pipettes for more than 2-3 minutes may give falsely elevated melatonin levels.

Use of salivettes may give falsely elevated melatonin levels, standards should be run through salivettes to correct for this.

Urine aMT6s

Ask subjects to collect all urine passed over a preset period into a standard urine bottle. Measure and record the volume, store circa 5 ml at -20°C. Urine should be collected at least every 3-4 h (longer during sleep period) for at least 24 h, preferably for 48 h or longer.

Do not wash urine bottles with bleach or another oxidant. No preservative is required aMT6s is stable in urine for 1 day at room temperature, 2 days at 4°C and for at least 2 years at - 20°C.

For further details see www.stockgrand.co.uk

Sampling details for measurement of melatonin and aMT6s

(12)

Melatonin and aMT6s measurement in shift work

Professor Josephine Arendt

Field studies

Different shift schedules

Hall, English, Arendt., unpublished

Rotating shifts

No or little circadian adaptation (aMT6s)

24 6 12 18 24 time h

Early Early Early

Late

Late

Night Night Night

Late

Three day fast rotation shift

no data

*

*

*

*

*

*

*

*

*

*

*

*

Sleep

aMT6s peak internal clock position

*

(13)

People who do adapt to night shift

Barnes et al, 1998;2000; Gibbs et al, 2002; 2005

Stable shift – adapt to night shift

Barnes et al., 2000

(14)

Adapted to nightshift

aMT6s acrophase during a night shift

14 day night shift: 18.00-06.00 h offshore Gibbs et al., 2005

Night shift

a M T 6 s a cr o p h a se tim e (h)

Adaptation depends on:

• Shift schedule (type and timing)

• Light/dark environment

• Season

Barnes et al, 1998;2000; Gibbs et al, 2002; 2005

(15)

Adaptation depends on:

• Shift schedule (type and timing)

• Light/dark environment

• Season

Problem if adapt to shift, then have to re-adapt to new shift/rest day

Papantoniou et al., 2014

Permanent night and day workers

(16)

Papantoniou et al., 2014

Urinary 6-sulphatoxymelatonin rhythms in permanent night workers

aMT6s Day workers

(n = 41)

Night workers (n = 72) aMT6s levels

(ng/mg creatinine/h)

15.4 (95% CI 12.3-19.3)

10.9*

(95% CI 9.5-12.6)

aMT6s peak time (h:min)

05:36 h 05:06-06:12)

08:42 h*

(95% CI 07:48-09:42)

Papantoniou et al., 2014

Urinary 6-sulphatoxymelatonin rhythms in permanent night workers

Lower aMT6s levels and later peak times

in permanent night workers

(17)

Individual differences in adaptation to shift work

Individual differences in adaptation to shift work

Gibbs et al., 2002

16 h to adapt by delay

8 h to adapt by advance

Days

Night Day

aM T 6s ac rop ha s e ti m e (h)

7 Nights (18.00-06.00 h) 7 Days (06.00-18.00 h)

(18)

0 4 8 12 16 20 24

1 3 5 7 9 11

nightshift dayshift 1800-0600h 0600-1800h

Shift change day

a M T 6 s a c rophas e h

2 3 4 5 6 7 8 9 10 11 12 13 Study day

Predicting response to shift change: aMT6s phase

Late initial phase

Intermediate initial phase

Early initial phase

Barnes et al, 1998a & b;

Gibbs et al, 2001; 2007 Shift in peak time of aMT6s

Michelle Gibbs

Data from North Sea oil rig shift workers who adapt rapidly to night shift work from 1800-0600h

Individual differences

predicting adaptation to shift work

• Genotype eg clock gene polymorphisms?

• Circadian period ()

• Circadian phase, chronotype

• Light sensitivity - retinal processing

• Age

• Sleep/wake patterns

• Light/dark exposure

(19)

Need an immediate marker of circadian phase

- online

- ambulatory conditions

- melatonin biosensor - “ClockWatcher”

- “LightWatcher”

Challenges

red, green, blue, uv, infrared

Ambulatory Circadian Monitoring

5,89 mm 58 mm 33 mm

58

mm • Activity

• Position

Peripheral temperature Light

exposure

17,35 mm

Bonmati-Carrion et al., 2014

Correlation with melatonin onset (DLMO)

(20)

mechanisms underpin inter-individual differences in response to shift work?

 design better and healthier shift-work schedules

Kantermann, T…..Skene, D.J., Prog. Brain Res., 2012

Biomarker challenge – shift work

• Global systems “-omics” approach Transcriptomics

Proteomics

Metabolomics

(21)

Biomarker challenge – shift work

• Shift work

Sleep restriction/sleep deprivation Circadian misalignment

Metabolic disturbance

• Elucidate underlying mechanisms

MetaDisIDQ kit (Biocrates)

• Absolute concentrations for 183 metabolites

10 μl plasma

Targeted metabolomics

Davies, S.K. et al., PNAS, 2014

(22)

• Effect of total sleep deprivation on metabolite rhythms

Sleep vs sleep deprivation metabolomics

Davies et al., PNAS, 2014

Metabolite rhythms

Davies, S.K. et al., PNAS, 2014

(23)

Thank you

d.skene@surrey.ac.uk

Referenzen

ÄHNLICHE DOKUMENTE

Sollten sich die Ergebnisse der Autoren in weiteren Studien bestätigen, so empfehlen sie, bei Patienten unter einer Imatinibtherapie die Serum- phosphat- und Vitamin-D-Spiegel

Wenn Sie eine größere Menge von Melatonin Vitabalans eingenommen haben, als Sie sollten oder ein Kind versehentlich Melatonin Vitabalans eingenommen hat, wenden Sie sich immer an

Alten Mäusen wurden die Zirbeldrüsen junger Mäuse und umgekehrt jüngeren Mäusen die Zirbeldrüse älterer Mäuse verpflanzt und die Lebensdauer miteinander verglichen.. Die

Results Plasma concentration vs time-profiles of total and active drug in responding and nonresponding volunteers Groups I and II and patients Groups III and IV after an oral dose

In September most of the control females had undetectable plasma leptin concentrations, but the melatonin-treated females had detectable concentrations significantly higher than

Zur Validierung der ELISA-Bestimmungen wurde eine erst kürzlich beschriebene Methode zur Messung von Melatonin mittels HPLC-FD nach vorheriger Derivatisierung des Melatonins

Die Anwendung von Melatonin bei Patienten mit Le- berfunktionsstörungen wird nicht empfohlen, bei Patienten mit einer schweren Niereninsuffizienz ist eine

On the contrary in the city of Los Angeles, the probability that, given a sunny day, the next day will be sunny again is 0.9, whereas the probability that a rainy day is followed