• Keine Ergebnisse gefunden

mp~ Floppy Disk Drives 250K-Byte to One Megabyte

N/A
N/A
Protected

Academic year: 2022

Aktie "mp~ Floppy Disk Drives 250K-Byte to One Megabyte "

Copied!
2
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

BAND POSITIONER Virtually frictionless.

Provides 5ms. access time. Extremely accurate and rei iable positioning.

HEAD AND CARRIAGE Head centered between two parallel rods to eliminate radial posi- tioning errors. Bottom head fixed; top head loads.

~ 1

5 ;"'h

ii

DISKETTE CENTERING

1

Clutch mechanism pro- vides most accurate diskette positioning (within .0008) and longest diskette life.

mp~ Floppy Disk Drives 250K-Byte to One Megabyte

MPI's high performance mini floppy disk drive family in- cludes single-sided double-density, and double-sided double density drives in both 48 and 96 TPI configurations. Unique features of the MPI drives are: • a patented stepper-band positioner • the industry's longest carriage • proprietary clutch and diskette ejector mechanisms • electronics pack- aged on a single PCB • low power consumption. Keyop- tions include a Shugart front door.

9754DeeringAvenue

mp~ a

Chatsworth, California 91311 Phone: (213) 709-4202 Telex: 910-494-1213

MICRO PERIPHERALS INC.

(2)

High-Performance Mini Floppy Disk Drives

MODEL 51

250K-Byte Capacity Single Sided

Double Density 48 TPI

MODEL 52

500K-Byte Capacity Dou ble Sided Double Density 48 TPI

MODEL 91

500K-Byte Capacity Single Sided

Double Density 96 TPI

MODEL 92

1 Megabyte Capacity Double Sided

Double Density 96 TPI

REPRESENTED BY

I I

ASSDEIATES

14431 MIRANDA CT.

lOS ALTOS HILLS CALIFORNIA 94022

(415)941-4133

Capacity Specifications (In 103 bytes) Single Density (unformatted)

Per Disk .. . . .•...•. . . .. . . . .. . . . Per Track .. . . ... . . .•..•••.... . . ... . . . Double Density (unformatted)

Per Disk ... . . . . .•... . . . ... Per Track . . . ... . . ... ... . . ... . . . Functional Specifications

Tracks ... ... .... . . ... . . . ... . . . .... . Track Density (TP!) .. ... ... . . . . . Recording Density (max. BPI)

Single Density . . . .... .... .. . . .... . Double Density . . . • • • • • . • ... . ... . . . Rotational Speed (RPM) ...•• • . . . .. . . Average Latency ...••.•... . . ... . . . ... T ra nsfer Rate

Single Density . . . .. . . .. . . ... . . . ... . . . Double Density ...••... . . . Encoding Method . . . . •••.•.•.•... . . .... ... . . . . Access Time

Track to Track . . . • . . . ...

Average . . . ... . . • . • . • . • • . . . . .. . . ... . .. Head Settling Time ... . . • . . . •... .... ... . . . Head Load Time ... . . . . ... . . . ... . . . ... . . . Power·Up Delay .. . . • • ... . . . ... . . . .. . . Interfacing .. .. .... . .. . . . • . . . ... . . ... . . .. . . Physical Specifications

Environmental

Operating Temperature ... . . . ... . Non·Operating Temperature ... . . . ... . . Operating Humidity .. . . ... ... ... ... . Non·Operating Humidity . . . ... . Electrical

DC Power ... . . .. . . . .. . . .... . Power 0 issipation .. .•• . . . ... . . . ... . Mechanical

Height . . . ... . . .. • . • . • . . . .. . . . ... .. . . ..

Width ... . . • . . • . • • . • . . • . . . ... . . .. Length . . . .. . . ...••••••.• ... . . .... Weight ... . . . • ... . . .. . . ...

Media Requirements

Diskette ...•••.... . . ...

Sectoring ...••. .• • • . • . . . ...

Type .. . . ... . . . • . . . . .... . .

Reliability Specifications

MTBF ... ... . . . ... . . • . . • • . ....

MTTR . . . ... . . . ... . . . .. . . • ....

Design Life ... . . . ...••..•. . . . ... Media Life . . . ... . . . • . •.•... .. Data Integrity

Soft Errors . . . ... ... . . ... . . .••. Hard Errors . . . .. . . .... . . .•.•.•.•

Seek Errors .. . . ... ... . . ... .

M R J!1 J!£

125 250 250 500

3.13 3.13 3.13 3.13

250 500 500 1000

6.25 6.25 6.25 6.25

40 80 80 160

48 48 96 96

2768 2938 2788 2961

5536 5876 5576 5922

300 ±1Y:.%

lOOms 125K bits/sec 250K bits/sec FM.MFM.M2FM

5ms

84ms (51/52) 150ms (91/92) 15ms

35ms 0.5sec Industry/ANSI compatible

40·F to 115"F (4.4·C to 46.1·C) -40·F to 160·F (·40·C to 7 l"C) 20% to 80% (non·condensing) 5% to 95% (non·condensing) +12V±5%. 0.8 Amp (1.5 Amp surge)

+5V±5%. 0.4 Amp 12W operation; 6W standby

3.25 in. (82.6 mm) 5.75 in. (146.1 mm) 7.75 in. (196.9 mm) 3.0 Ibs. (1.36kg) for 51/52 3.1Ibs. (1.41kg) for 91/92 Industry Compatible. 51{ in.

Soft; 10. 16 Single or Double Sided Single or Double Density

9.200 hours 0.5 hours

5 years 3x 1 06 passes/track 1 per 10' bits read 1 per 1012 bits read

1 per 106 see ks

UL And CSA Approved - - - -

Options Door Lock

Shugart Front Door (Add -S) Detailed design data available on request.

Referenzen

ÄHNLICHE DOKUMENTE

After the multipurpose, bus address, and disk address registers have been loaded, the control and status register is loaded to specify the drive number (0-3) and

The standard interface includes all Input and output lines used In the execution of basic data transfer and control operations.. Features providing additional

When Command Data or Configuration/Status Data is transferred, this signal line is used with the Transfer Acknowledge signal as a handshake signal. (4)

The relationship between step pulse period and access time in Full buffered and Semi-buffered Seek Modes are shown in Figure 1... STEP PULSE

If a miscompare error occurs during one or more Ultra DMA burst for any one command, at the end of the command, the device shall report the first error that occurred (see 5.5.5). 14)

When the FORMAT UNIT command is specified, the allocation of the alternate block to those defective sectors included in the defect lists (P, G, or D) is continued until all

The S-byte of the disk control field at the end of the operation contains the identifier of the last sector processed unless there is a missing address marker on the disk or