Pathology and clinical relevance of fetal blood flowjneasurements.

J.W. WLADIMIROFF, H.M. TONGE, P.C. STRUIJK Department of Obstetrics and Gynaecology Academic Hospital Rotterdam-Dijkzigt 3015 GD ROTTERDAM, THE NETHERLANDS.

Ά considerable number of studies have appeared on volume blood flow in the umbilical vein and fetal descending aorta (2). Although in vitro

experiments demonstrate an acceptable accuracy of volume flow measurements for present pulsed Doppler equipment, studies in the fetal lamb indicate that these measurements should be considered with caution, mainly due to problems related to estimations of fetal vessel size.

Qualitative analysis of flow velocity waveforms in the fetal thoracic

descending aorta and umbilical artery has demonstrated a typically biphasic pattern with a systolic peak and continuing forward velocity throughout diastole. The latter is typical of an arterial supply to a low cesistance peripheral vasculature placenta (3,4) . A reduction in diastolic flow

velocities in the descending aorta and umbilical artery in severe IUGR has been recorded, indicating increased placental vascular resistance (3,4).

In Rotterdam, aortic blood flow velocity and pulsatile vessel diameter (T-D recorder) were compared in cardiac cycles of equal R-R intervals ( +_ 5%) as obtained by an external ECG (5).

Within one cardiac cycle, both variables were analysed every 5 msecs resulting in a total of 80-100 measuring points per cardiac cycle (Apple Computer). Apart from a detailed analysis of the flow velocity and pulsatile vessel diameter profile, it also allows the construction of a volume flow profile within one cycle (Fig.l).

Finally, more information should be collected under physiological

circumstances. It has been shown in the fetal lamb, that fetal behavorial states do affect fetal blood flow (1). The application of fetal blood flow measurements to clinical situations can only be adequately

assessed in combination with cardiac function studies.

J.Perinat.Med. 12(1984)

Copyright by Walter de Gruyter & Co., Berlin-New York

(2)

246

Figure 1.:

Computer printout of mean flow velocity ( A ) , pulsatile vessel diameter (B) and resulting volume flow profile (C) for one cardiac cycle in the thoracic descending aorta. From left to right: normal flow patterns (32 wks), fetal hydrops, severe fetal anaemia (29 wks); severe IUGR (33 wks), note absent diastolic flow; severe IUGR with late FHR decelerations, note reduced systolic and diastolic flow, Caesarean Sections800g infant at 34 wks, umb. art. pH: 7.05.

z

*8

VI

t t

i I

! I

V,.

: A

Bibliography:

1. CLAPP J.F., SZETS H . H . , ABRAMS R . , LARROW R., MANN L.I.Physiologic variability and fetal electro-cortical activity. Am.J.Obstet.Gynecol.

136 (1980) 1054.

2. EIK-NES S.H., BRUBAKK A.O., ULSTEIN M.: Measurement of human fetal blood flow. Br.Med.J. 1 (1980) 280.

3. GRIFFIN D., COHEN-OVERBEEK T., CAMPBELL S.: Fetal and utero-placental blood flow. In: S. CAMPBELL: Ultrasound in Obstetrics and Gynaecology.

Recent Advances. Clinics in Obstetrics and Gynaecology. Saunders Company Ltd. London, 1983.

4. REUWER P.J.U.M., STOUTENBEEK Ph., BRUINSE U.W, NUYEN W.C., HEETHAAR K.M.: Doppler blood flow pulsatility in the umbilical arteries.

Europ.J.Obst.Gynec.Reprod.Biol. (1984) in press.

5. TONGE H.M., STRUIJK P.C., CUSTERS P., WLADIMIROFF J.W.: Vascular dynamics in the descending aorta of the human fetus in normal late pregnancy. Early Hum.Dev. 9 (1983) 21.

J.Perinat.Med. 12(198O

Referenzen

ÄHNLICHE DOKUMENTE

The aims of this study were the following: (a) to assess the regional blood flow distribution within the splanch- nic circulation, (b) to compare regional perfusion, oxy-

We conclude that: (1) changes in the distribution of MBF in the gastrointestinal tract during acute haemorrhage are heterogeneous and cannot be predicted from changes in systemic

The pulsed Doppler in the measuring set-up used here is based on the relationship between power spectrum for the Doppler spectrum and the velocity distribution for the red cells..

Blood flow velocity, pulsatile vessel diameter and volume flow data at the lower thoracic level fo the fetal descending aorta according to fetal ECG (FECG) and first

The results of the present experiments thus in- dicate that maternal hyperoxia will produce constriction of the total uterine vascular bed which will result in a diminished quantity

Our results indicate that Spectral Clustering as well as Agglomerative Hierarchical Clustering with average link or Ward’s method as proximity measure generate meaningful groups

The determination of the flow properties of a fluid containing a cylindrical inclusion with its long axis oriented parallel to the vorticity direction is a 2-dimensional problem

Since the flow regime in the same soil can be dominated either by preferential flow or by uniform matrix flow (as at the.. French site, for instance), the risk of vertical