• Keine Ergebnisse gefunden

Distance list

N/A
N/A
Protected

Academic year: 2022

Aktie "Distance list"

Copied!
1
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Paul Scherrer Institut Distance list SLS - MS BL X04SA

DOMAIN COMPONENT

DISTANCE D

[m]

Height [mm]

D x [mm]

D y [mm]

D z

[mm] REMARKS

Front End

Mask 8.245 1400 D=center

front end

BPM 1 8.58 1400 D=center

front end

Photon Shutter 1400 D=center

front end

Beam Stopper 1400 D=center

front end

BPM 2 11.624 1400 D=center

front end

BPM 1 - BPM 2 3.044

front end

Diaphragm 1 12.51 1400 D=center

front end

Diaphragm 2 17.054 1400 D=center

front end

CVD Filter 17.636 1400 D=center

front end

CCD Window 17.851 1400 D=center

front end

END of FE 18.3 1400

OPTICS

FSX 18.779 1400

optics

Filter 1 (CVD) 18.855 1400 20 10

optics

Filter 2 (Si) 18.98 1400 20 10

optics

Slits ring 19.169 1400 10

optics

Slits wall 19.219 1400 10

optics

Slits up 19.269 1400 10

optics

Slits down 19.319 1400 10

optics

4QM1 19.39 1400 9 3

optics

Crystal 1 20.142 1400 20 40 30

optics

Crystal 2 ~ 20.2 - 20.5 9 0.4 40

optics

4QM2 20.69 9 3

optics

Mirror 1 21.514 40 40 400

optics

Mirror 2 22.214 40 40 400

optics

Cry 1 - MI1 1.3715

optics

MI1 - MI2 0.7

optics

Si3N4 Window 23.053 1400/1420 Ø6 …

optics

4QM3 23.326 9 3

optics

beam stopper 23.772 1400 Ø110 180 D=beam entrance

EH1

BSB 30.485

EH1

slits vert. ~ 30.9 1400 D=center

EH1

slits horiz. ~ 31 1400 D=center

EH1

filter unit 1420 D=center of unit

EH1

JJ slits horiz. 1420 Ø40 D=center

EH1

JJ slits vert. 1420 Ø40 D=center

EH1

ionisation chamber 1420 30 10 D=beam exit

EH1

powder diffractometer 32.79684 1420 D=center of diffr.

EH1

center of sample to center of analyser cryst. 700mm

EH1

center of analyser cryst. to detectors

EH1

center of sample to micro strip detector 760mm

EH1

x-ray eye

EH1

station shutter 37.918 1400 35 D=center

EH2

filter unit 1 38.87 1420 D=center of unit

EH2

filter unit 2 38.97 1420 D=center of unit

EH2

JJ slits horiz. 39.09 1420 Ø40 D=center

EH2

JJ slits vert. 39.29 1420 Ø40 D=center

EH2

ionisation chamber 39.244 1420 30 10 D=beam exit

EH2

surface diffractometer 40.0865 1420 D=center

EH2

x-ray eye at rear wall 43.28

189.32mm to 301.57mm

Distance list.xls Page 1 / 1 D. Meister, 28.10.2011

Referenzen

ÄHNLICHE DOKUMENTE

Figure 9.1. Breakdowns of the water network in areas with first surface deformation class in 2004-2009. Failure occurrences in 2008 and 2009 are given, in single figures..

1.2 Choose Representative Tasks for Task-Centered Design After establishing a good understanding of the users and their tasks, a more traditional design process might abstract away

The endogenous agreement model where traffic policeman has advantageous bargaining power and the possibility to inflate the fine while attempting to extort a bribe

Mudd Building, 250 Longwood Avenue, Boston, MA 02115, United States of America Department of Medicine, Division of Infectious Diseases, George Washington University Medical Center,

The aim of this thesis is to provide an insight and a better understanding at Estonia’s current immigration policies and measures in the specific context of attracting

The PCAs offer little in the area of economic integration: the MFN clause, some technical, legal and institutional cooperation in such sectors as transportation,

Paradoxically, the mutually constitutive links between the (domestic) agents and the (international) structures represented by global institutions (GIs), actors, multinational

The current fiscal imbalances and fragilities in the Southern and Eastern Mediterranean countries (SEMC) are the result of decades of instability, but have become more visible