B 1 000 Series

N/A
N/A
Protected

Academic year: 2022

Aktie "B 1 000 Series "

Copied!
4
0
0

Wird geladen.... (Jetzt Volltext ansehen)

Volltext

(1)

Burrough s

B 1 000 Series

SMCS

Reference Card

(Relative to SMCS 10.0.007)

ATTACH

Attaches a station to a program or remote file.

Controller and system DDT syntax:

ATTACH-,---~---~~

TOIF'LE

T<

remote file nurnber>

<

remote file name>

PROG RAM

L

< program name>

<

job number>

~>-~----.--~L--,r- <

Isn

~

1

LSTATlON~ L:'::ationname>~

BROADCAST

Sends a message to all logged-on stations.

Syntax:

BROADCAST - ,- ---,--- -- < message string> ---1

L . ----.J

BYE

Logs the user off the SMCS program.

Workstation, remote DDT, and controller syntax:

~YE---1

CHANGE

Changes various station attributes.

Controlier and system ODT s:'ntax:

ADDR ESS ---.-~---__,_-< value> - ---,---1

ADDRESS (RECEIVE) ADDRESS (TRANSMIT) FREQUENCY (RECEIVE) FREQUENCY (TRANSMIT) PHONE---~

RETRIES ---1

TERMINALTYPE TRAN (RECEIVE) TRAN (TRANSMIT)

DIAGNOSTIC - - - - ---,---,--- -- -- --,---__,_- ON - -- ---.----'

GOODRESULTS OFF

LOGICALACK TRUE

READY FALSE

Copyright © 1983 Burroughs Corporation, Detroit., Michigan 48232

Printed in U.S.A. (2-83) _ 1 . 1151875

CLEAR

Clears a remote file.

Controller and system DDT syntax'

CLEAR F1LE - - - - r - < remote file number ~ L - -< remote file name>

CLOSE Command Closes the JOBS file.

Controller and system DDT syntax:

CLOSE---~

CONTiNUE Command

Causes a step macro procedure to resume.

Workstation, remote DDT, and controller syntax:

CONTINUE - --- --- -____1

DETACH

Detaches a station from a program or remote file.

Controller and system DDT syntax:

DETACH~---_.---~

FROMTPROGRAM L<program name>

L

< job number> -

FILE L < remote file number>

< remote file name>

~..- ___ ____ -,----J I _ C~<

Isn > ________

~-'---__I

LSTATIONJ L<stationname>

_-I

DUMP

Causes an SMCS program dump to be created_

Controller and system DDT syntax:

DUMP- - - -- -- - - -- -- -- ---!

DYNAMIC

Controls the method by which stations are marked off-line.

System ODT syntax:

DYNAMIC --,-E---~-~-F-~---,---1

FILE

Provides information on a file.

Syntax:

FILE

L

~-< file-identifier

>----1

- L <

family name>

/J

< multi-file id >...-J

HARDWARE

Specifies the recordsize of the TRACE file.

System ODT syntax:

HARDWARELP---,~--'-3-2-~-,---~

C:'

20

----.l

-2-

(2)

HELP

Provides a list of all valid commands for the sta ton.

Syntax:

ljELP

ID

Assigns an identifier to the station.

Workstation, remote OOT, and controller syntax:

10 < identifier> - r

t --- . -.

- - - ---rl- - - - ----j

< command stong >---1

! < macro procedure> I--.---J

INITIATE

Initiates a program in the JOBS file at the system DDT.

System DDT syntax:

INITIATE <program-id>---- - ---j JOBS

Returns information on jobs in the mix. Workstation, remote DDT, and controller syntax:

,OBS---~

LOGON

Adds, changes, deletes, or lists the default log-on command.

Workstation, remote DDT, and controller syntax:

LOGON ADD - - - - -~--<: logon command> - - - - r= - - - j

1 CHANGE ~

L ! <macroprocedure» DELETE---- - - -- - -- ---j LlST---~

MACRO

Adds, changes, deletes or lists macro procedures.

Controller syntax:

< macro text >- , -- - - 1 MACRO T A D D ---,--< macm name>

CHANG E---.J

DE LETE < macro name > ---~

LIST - - - , - -- - - -- ----r- - ----1

< macro name>

ON-~~~~~~~~~~~~~

Workstation and remote DDT syntax:

MACR0

1

ADD ~<macroname> < macro text>

CHANGE~

DELETE <macroname>---~

LlST- - - r -- - - . -- - ---'

< macro name>

System DDT syntax:

MACROON---_~

MAll

Writes messages to the MAIL file.

Syntax:

MAIL--,- -- - ---,--,---__________ _

L

< identifier>

-.J L<

message string> _

J

-3-

MAKE

Changes certain station attributes.

Workstation and remote OOT syntax:

MAKE

- ' 1 -'-

I--No-T-~--'--SCROLL REVERSE

L

SIGNAL < character> - - - ' Controller syntax:

STATION <station name>J

LNOT~

LCON---l

MAKE

_~ <Isn>

-I T READY-,---j

- - SIGNAL <character> 0.- - - - - -

1

--1

SCROLLREVERSE---~

NOT System OOT syntax:

MAKE

~~---'-r- LSTATlON ~

L<station < Isn >

name >~ - ,-,---,-'C-

L NOTJ

READ~

CON

DDT

MOVE

Reroutes messages from one station to another station.

Controller and system OOT syntax:

MOVE1<num~be,> L

J

<Isn> >

-ALL FROM LSTATIONJ

L-< station name >~

ONE

>--~TO - , - - - ,, - < dest lsn > - - - - ,- - -_

L STATION

=-oJ

L<dest name>==:]

NEWS

Displays or changes the news message.

Workstation and controller syntax:

~EWS---~

Remote DDT and system DDT syntax:

~EWS--,c=---r---~

C;

news message>

=J

PASS

Requests a function of a program without signing on to the program.

Workstation, remote DDT, and controller syntax:

PASS < program·id > < data string> - - - -- -

PASSWORD

Sets or resets the COBOL 74 password.

System ODT syntax:

pAS~O RD

----c

~ password>

=y-

READY

Makes a station ready.

Syntax:

READY ---,,--< Isn > - - - , - -- - - 1 L < station name

>~

-4-

~J...r(

(3)

REMOVE

Removes messages from a station.

Controller and system DDT syntax:

A EMOVE

t <

number>

-

ALL~

ONE

>>---~--< Isn > ,

L <

station name

> ~

REPORT

Displays information on the status of a station or stations.

Syntax:

~EPORT----,---~---~

- -- - ALL ---1

SEND

Sends a message to the specified stations.

Syntax:

SEND-r---.-,-,---,~r_

< usercode >- - -- - - -- - - --1

<

identifier

>-_____ ____

~

>>-- - T - - - ' - - < message. string > - - -- - - -- - ---i L .-.-J

SIGN OFF

Detaches a user from a program.

Workstation, remote DDT, and controller syntax:

< signal character> - - T -- --,----OFF---,- - -- - - , - -- - - - -

L SIGN

-.J

L CLEAR-.-J

SIGN ON

Attaches a user to the specified program.

Workstation, remote DDT, amd controller syntax:

SIGNAL

< program-id > ~

L<jOb nUmber > ~

L<string>J

Changes the SMCS signal character for all stations.

Controller and system DDT syntax:

SIGNAL < signal character >-- -______ ___ -1

·5·

STATUS

Displays the current status of a station. program, or remote file.

Syntax:

STATUS-.---r-r---,-~--~

STOP

STATION < usercode > - - ----I

< identifier> - - - --

< station name>

<Isn >---~

PROGAAM~<program name>

--T-

L < job number>

F I LE~' --- - - , -< remote file name>

L<

remote file number>

Terminates the SMC$ program in an orderly manner.

System DDT syntax:

STOP'- -- - - -- -- - - -- - - -

SYSTEM

Displays information on the SMCS version, translate option, and system Hostname.

and changes the translate option.

Workstation syntax:

SYSTEM - TC- - - --- - - r - -- -- - - -- ---t TRANSLATE

-~

VERSION~

Remote DDT and system DDT syntax:

SYSTEM--T---r---~

t TRANSLATEt~~F ~

VERSION- - - - -- -- ---'

TABS

Sets the tab stops on a terminal.

Syntax:

< start col> +

<

increment> - - -- ----' TERMINATE

Terminates a step macro procedure.

Workstation, remote DDT, and controller syntax:

TERMINATE--- - - -- - -- - ---j

·6·

(4)

TRACE

Invokes the SMCS tracing facilitie.;.

Controller and system COT syntax:

TRACE

---,---ON~-,---

DISK OFF MARK LIST

TRANSLATE

Sets or resets the translate option for a station.

Workstation, remote GOT, and controller syntax:

TRANSLATE---,c==---~---,---4

L~~F~

USER

Logs a user on to the SMCS program.

Workstation, remote DDT, and controller syntax:

~E R < usercode!password >--,---,---_4

L<

command string>- - - J

L ( <

macro procedure> I

~

ZIP

Spawns an unsecured Mep control string.

Remote DDT syntax:

liP

Y L <

MC=;:ntrO[ instruction>

~---,--L---_4

I < macro procedure> 1 ~

? < Mep control instruction>

Spawns a secured Mep control string.

Workstation, remote DDT, and controller syntax:

- - - ---,----rL--

rL - <

MCP control instruction

>---,

1--L---_4

?

~

[

<

macro procedure> I---.J

-7-

NOTES

-8-

Referenzen

ÄHNLICHE DOKUMENTE

Four models are currently offered: the UT-I, which is based on a Data General Nova minicomputer and provides for high-volume remote batch terminal operations;

The RAM Address Setup command sets an address into the Address counter to write data into DDRAM, CGRAM and Symbol register. When the cursor display is ON, the cursor is located at

In the SED1230 Series where the built-in liquid crystal power circuit is not used, the RES input must be active when the external liquid crystal power supply is turned on.. After

Note: Set the cursor address to the start of each screen’s layer memory, and use MWRITE to fill the memory with space characters, 20H (text screen only) or 00H (graphics screen

In the SED 1230 Series where the built-in liquid crystal power circuit is not used, the RES input must be active when the external liquid crystal power supply is turned on.... In

The power circuit built in the SED1240 series is a low power consumption power circuit that generates a voltage required for liquid crystal drive, and consists of a boosting

If a handler attempts to handle the exception either by calling the system procedure $raiseReturn or by terminating the execution of its Handle Statement, a runtime error occurs.

The methods are the optimal partitioning algorithm with cost functions linear RSS, quadratic RSS, the likelihood regression function and the likelihood mean function, the